Search Search all

Chiller Control System

ClassificationIndustry News 155

Chiller Control System

 

The cooling capacity of the chiller control system is directly related to the operating conditions of the system. For compressors with the same structure, the same speed, and the same refrigerant type, as the evaporation temperature decreases, the compression ratio of the compressor increases, and the energy consumption per unit of cooling capacity increases. So, what are the reasons for the increase in power consumption when the chiller control system is running?

1. When the compressor encounters frost, the small suction valve will be closed quickly, the cooling capacity will be drastically reduced, and the power consumption will be relatively increased.

2. As the condensing temperature increases, the compression ratio of the compressor increases, and the energy consumption per unit cooling capacity increases. For every 1°C increase in condensing temperature between 25°C and 40°C, power consumption increases by about 3.2%.

3. The surface of the evaporator is covered with a layer of frost, which reduces the heat transfer coefficient. In particular, the outer surface of the finned tube is frosted, which not only increases the heat transfer resistance, but also makes it difficult for the air to flow between the fins and reduces the appearance. Heat transfer coefficient and heat dissipation area. When the indoor temperature is lower than 0°C, when the temperature difference between the two sides of the evaporator tube group is 10°C, the heat transfer coefficient of the evaporator is about 70 after one month of work before frosting.

4. When the heat exchange surface of the condenser and evaporator is covered with a layer of oil, the condensation temperature rises and the evaporation temperature decreases, resulting in a decrease in cooling capacity and an increase in power consumption. When a 0.1mm thick oil layer accumulates on the inner surface of the condenser, the cooling capacity of the compressor will decrease by 16.6, and the power consumption will increase by 12.4. When the oil is 0.1mm thick in the inner surface type evaporator, in order to maintain the predetermined low temperature requirement, the evaporation temperature drops by 2.5°C and the power consumption increases by 9.7°C.

5. When the air gathers in the condenser, the pressure of the condenser will increase. When the partial pressure of non-condensable gas reaches 1.96105Pa, the power consumption of the compressor needs to be increased by 18.

6. As the evaporation temperature decreases, the compression ratio of the compressor increases, and the energy consumption per unit of production cooling increases. When the evaporation temperature is lowered by 1°C, it consumes 3% to 4%. Therefore, minimizing the evaporation temperature difference and increasing the evaporation temperature not only saves energy consumption, but also increases the relative humidity of the cold room.

7. When the size of the condenser wall reaches 1.5mm, the condensation temperature rises by 2.8°C before the temperature calibration, and the power consumption increases by 9.7°C.

8. The gas inhaled by the compressor is allowed to overheat to a certain extent, but if the overheat is too large, the specific volume of the inhaled gas will increase, the cooling capacity will decrease, and the relative power consumption will increase.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller