The daily inspection of the industrial glycol chiller system after purchase is very important. Doing a good job in daily inspection can reduce a lot of failure rates and maintenance costs, and reduce losses to the enterprise. So how to do a good job in the daily inspection work, let’s take you to understand the daily inspection and maintenance work of the industrial glycol chiller system.
1. The start-up inspection of the industrial glycol chiller system, check whether the line power supply is powered on, and ensure that the unit can start and run normally.
2. As the core of the industrial glycol chiller system, the compressor determines the performance of the industrial chiller, so it is very important to do a good job in the daily inspection of the compressor.
3. The high and low pressure gauges are mainly used to monitor the operation of the industrial glycol chiller system. Pay attention to the value changes on the pressure gauge at any time. If the value of the pressure gauge changes, there is a problem with the chiller.
4. Observe the temperature of the industrial glycol chiller system during operation. If the temperature is too high, it is an overload operation, and high and low alarms will appear at that time, causing the whole unit to fail.
5. Check and clean the condenser and evaporator regularly to avoid blockage and loss.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -150°C to -5°C
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW |
Recirculating Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers
Temperature Control Range: +5°C to +50°C
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments
Temperature Control Range: -120°C to -10°C
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |
Screw Chillers
Low temperature screw chillers and room temperature screw chillers
Customized solutions for your business.
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |