The industrial chilled water system mainly consists of four parts: industrial heating equipment, industrial cooling equipment, circulating water pumps and industrial pipelines. The types of circulating water cooling systems can be divided into two types, open type and closed type. Its working process is to exchange heat with the industrial cooling medium, lower the temperature, and then flow back into the industrial production heating equipment for recycling. The industrial circulating medium is used as the media to transfer the heat generated by the production equipment to the outside world.
Cooling medium for industrial chilled water system
Industrial chilled water systems generally use water as the cooling medium material, and some use hydraulic oil, alcohol, air, salt water, antifreeze or refrigerant as the cooling medium.
Composition of industrial chilled water system
The industrial chilled water system is mainly composed of industrial cooling equipment and circulating water pumps.
How industrial chilled water system works?
1. Closed cooling tower: The industrial circulating medium is pressurized by the circulating pump, passes through the industrial pipeline, and is sent to the industrial production heating equipment. The circulating medium receives heat energy, the temperature rises, passes through the industrial pipeline again, and enters the heat exchange tube bundle of the closed cooling tower. Closed cooling reduces the temperature, the temperature drops, and enters the circulation pump, and the cycle repeats.
2. Open cooling tower: The circulation pump draws circulating water from the pool, passes through the industrial pipeline, and sends it to the industrial production heating equipment. The temperature rises, passes through the industrial pipeline again, enters the top of the open cooling tower, sprays downward for cooling, and flows into In the bottom pool, it enters the circulation pump, and the cycle repeats.
Advantages of industrial chilled water system
After the medium with low temperature passes through the required production equipment (such as blast furnace, reactor, etc.), the temperature will increase. If it is discharged directly, it will only be used once. If the water with increased temperature passes through the cooling equipment, then the water temperature It will be reduced and can be reused again, and the water consumption will be greatly reduced. Generally, more than 95% of water can be saved, which plays a large role in saving water in industrial water.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Precision Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW |
Recirculating Chillers
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW |
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Liquid Cooling For Battery Energy Storage Systems
Types | For Converting Station | For Energy Storage Battery | For Charging Station |
Cooling Capacity | 45kW | 5 ~ 8.5kW | 4kW |
ZLFQ Series
Coolant Distribution Unit
Liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places.
Temperature range | +5°C ~ +35°C | +5°C ~ +35°C |
Cooling Capacity | 15 ~ 150kW | 200 ~ 500kW |
MD Thermal Chucks Series
It is used for testing RF devices and high-density power devices (IGBTs and MOSFETs), and can also be used for rapid cooling of laboratory flat panels (plasma, biological products, batteries), etc.
Temperature range | -75°C ~ +225°C |
Temperature accuracy | ±0.1℃ |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | 107 ~ 1027kW (Single Compressor) | 299 ~ 2134kW (Dual Compressor) | 98 ~ 934kW (Single Compressor) | 272 ~ 1940kW (Dual Compressor) | 48 ~ 467kW (Single Compressor) | 51 ~ 497kW (Single Compressor) |