Search Search all

Chiller and Heater System

ClassificationIndustry News 279 0

Chiller and Heater System

Contact us today for the perfect temperature control solution

 

The chiller and heater system is mainly used in: high-pressure reactors, pilot production stainless steel reactors, double-layer glass reactors, jacketed reactors, micro-channel reactors, reaction devices, combined chemistry and other cold and heat source dynamic constant temperature control and the pharmaceutical industry Among low-temperature distillation, rectification, extraction and other equipment, this series can provide a temperature control range of -120℃ ~ +250℃, and can be upgraded to high temperature to 300℃. It is especially suitable for rapid exothermic and endothermic chemical reaction experiments.

 

Chiller and Heater System

 

The features of chiller and heater system are as follows:

1. A magnetically coupled high-temperature circulation pump is used to eliminate the risk of system leakage, with good sealing and high flow rate, ensuring that the equipment can exchange heat for the external system faster.

2. Only the medium in the pipeline participates in cyclic temperature control, which reduces the amount of heat transfer medium involved and improves the response speed of the system’s high and low temperature control.

3. Equipped with a user-friendly 7-inch true-color LCD touch screen, a good human-computer interaction interface, and intuitive display of local machine parameters and external temperature control parameters. Smart touch, easy to operate.

4. Design multiple sets of communication data interfaces to easily access various communication networks.

5. Reasonable layout: Frequent operations are in front of the equipment, pipeline connections are at the rear of the equipment, and the data interface is set on the side of the equipment.

6. The standard configuration is air-cooling, which requires no external water source and is easy to install and operate; the water-cooling type has stable heat dissipation efficiency and is not affected by the ambient temperature.

7. Considering the needs of chemical customers, isolation and explosion-proof and positive pressure explosion-proof models can be customized according to the customer’s equipment placement area.

8. A single device can have multiple outputs, with multiple reactors and reactor loads. Each channel can achieve independent temperature control, saving space.

 

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Cooling and Heating Systems (SUNDI series)

(Custom Designs)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kWup to 10*2kWup to 10*2kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Cooling and Heating Systems (WTD series)

(Custom Designs)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Cooling and Heating Circulators

(Custom Designs)

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Heating Circulators

(Custom Designs)

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +170°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacity5.5 ~ 15kW3.5 ~ 130kW3.5 ~ 95kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

TCU Multi-reactors Temperature Control System

(Custom Designs)

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller