Chiller 10kw – Low Temperature Chillers

ClassificationIndustry News 237

Chiller 10kw – Low Temperature Chillers

 

As a kind of industrial equipment, the 10 kw chiller will have some problems after a long time of use. The most serious situation is the sudden shutdown of the equipment. Once this situation cannot be effectively resolved, it may lead to serious accidents. Now let me show you how to deal with the sudden shutdown of the 10 kw chiller?

1. A sudden power outage caused the 10 kw chiller to shut down

During the operation of the refrigeration compressor, if there is a sudden power failure, first disconnect the main power switch, immediately close the suction valve and discharge valve of the compressor, then close the liquid supply gate valve, stop the liquid supply to the evaporator, and prevent the next operation of the 10 kw chiller , the humidity of the evaporator shrinks due to too much liquid.

2. The sudden water cut off caused the shutdown of the 10 kw chiller.

If the refrigeration circulating water is cut off suddenly, the switching power supply should be cut off immediately, and the operation of the refrigeration compressor should be stopped to prevent the working pressure of the equipment from being too high. After the air compressor stops, the suction and exhaust valves and related liquid supply valves should be closed immediately. After the cause is found out and common faults are eliminated, the power supply should be repaired and then restarted.

3. Shutdown caused by common faults of 10 kw chiller compressor

When the compressor is shut down due to damage to a part of the compressor during operation, it can be operated as a normal shutdown if conditions permit. In case of emergency, disconnect the motor switch power supply, and then close the suction, exhaust valve and liquid supply gate valve.

4. Downtime caused by fire

When a fire broke out in an adjacent building, the performance stability of the 10 kw chiller was seriously threatened. The user needs to turn off the power, quickly open the exhaust valves of the liquid storage tank, refrigerator, filter, evaporator, etc., quickly open the emergency ammonia unloader and water inlet valve, so that the solution of the system software is discharged at the emergency unloading port, and use a large amount of water Dilute to prevent fire accidents from spreading and causing accidents.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller