Heater Chiller Circulator
The use effect and operation process of the heater chiller circulator are inseparable from the pre-installation and environmental factors. When using the heater chiller circulator, you also need to pay attention to some precautions.
First, the installation precautions of the heater chiller circulator:
1. The heater chiller circulator has certain conditions for the environment. It is recommended to place it on a firm, stable, level ground with a certain amount of space around it to facilitate the heat dissipation of the equipment, as well as for later repairs or maintenance.
2. The power supply of the heater chiller circulator generally uses three-phase four-wire. If there is an unconventional model, you need to pay attention to distinguish it. Prepare the power supply, zero connection, grounding and other lines in advance to ensure that the connection is tight.
3. Equipped with various overload protections, do not modify it by yourself to cause malfunction.
4. When the heater chiller circulator is being hoisted, care must be taken on site not to cause the equipment to be impacted and damage the display screen while moving.
5. Pay attention to avoid places with dangerous flammable gases and places with acid solutions, and avoid the influence of high-frequency equipment products.
6. The heater chiller circulator should be placed in a dry environment to avoid equipment damage due to high ambient temperature.
Second, precautions for using the heater chiller circulator:
1. The heater chiller circulator will be issued with a product manual when it leaves the factory. Users need to have a certain understanding of the various interfaces, buttons, and screens around the device before operating it. During the use of the equipment, it is necessary to use it strictly in accordance with the equipment manual, and operate according to the use and maintenance, otherwise it will affect the service life of the equipment.
2. Before using the heater chiller circulator, it is necessary to check whether the equipment is in a normal state, and it is necessary to formulate a maintenance plan.
3. When selecting the heat transfer medium of the heater chiller circulator, it is necessary to pay attention to whether its temperature range meets the requirements of the working conditions of the project and whether it is suitable for the use of the equipment. The heat conduction medium needs to be replaced regularly after long-term use. It is recommended to use the same type of medium to avoid equipment blockage caused by heat conduction medium of different models and different brands.
4. There are many types of pipes in the heater chiller circulator. Choose which material is suitable according to the temperature requirements of the equipment model, and then choose according to the length and diameter. It is necessary to regularly check the consumption of the pipes, check whether there is damage, and replace them in time.
Soluções personalizadas para o seu negócio
Sistemas de arrefecimento e aquecimento (série SUNDI)
Gama de controlo de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -40 ~ +200°C | Série -10 ~ +200°C | Série -25 ~ +200°C | Série -25 ~ +300°C | Série -45 ~ +250°C | Série -45 ~ +300°C | Série -60 ~ +250°C | Série -60 ~ +300°C | Série -70 ~ +250°C | Série -80 ~ +250°C | Série -90 ~ +250°C | Série -100 ~ +100°C | -25 ~ +200°C uma máquina para dois reactores | -40 ~ +200°C uma máquina para dois reactores |
Capacidade de arrefecimento | até 3kW | até 15kW | até 200kW | até 200kW | até 200kW | até 25kW | até 60kW | até 25kW | até 15kW | até 80kW | até 80kW | até 80kW | até 10*2kW | até 10*2kW |
Sistemas de arrefecimento e aquecimento (série WTD)
(Reactores de canal micro / tubo especializados)
Gama de controlo de temperatura: -70°C a +300°C
Design especializado para micro canal (pequena capacidade de retenção de líquido, forte capacidade de troca de calor, sistema de circulação de alta queda de pressão)
Gama de temperaturas | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidade de arrefecimento | up to 7.5kW | up to 5.5kW | até 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Gama de temperaturas | Série -45°C ~ +250°C | Série -85°C ~ +200°C | Série -60°C ~ +200°C |
Capacidade de arrefecimento | até 25kW | até 25kW | até 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Gama de temperaturas | Série -20°C ~ +80°C | Série -45°C ~ +80°C | Série -60°C ~ +80°C | Série -80°C ~ +80°C |
Controlo do fluxo | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de arrefecimento e aquecimento
Gama de controlo de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -25°C ~ +200°C | Série -45°C ~ +250°C |
Capacidade de arrefecimento | até 15kW | até 15kW |
Circuladores de aquecimento
Gama de controlo de temperatura: +50°C a +300°C
Nota: A série UC pode controlar a temperatura do meio de transferência de calor. A série UST pode não só controlar a temperatura do meio de transferência de calor, mas também controlar a temperatura do material de reação.
Gama de temperaturas | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (série UC) | +50°C ~ +300°C (série UST) |
Capacidade de aquecimento | até 38kW | até 200kW | até 95kW |
TCU Sistema de controlo da temperatura de multi-reactores
Gama de controlo de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -45°C ~ +250°C | Série -120°C ~ +250°C | Sistema de controlo de temperatura personalizado | RT+10°C ~ +135°C |
Capacidade de aquecimento | até 80kW | até 80kW | Personalizado | up to 300kW |