Data Center Chilled Water System

 

Driven by developments in artificial intelligence, edge computing and the Internet of Things, modular data centers have become a critical component of successful operations for many businesses. The increasing reliance on computing makes the limitations of traditional modular data centers even more apparent. These disadvantages include a lack of flexibility, inefficiencies due to scale, and high costs associated with local transaction work.

Demands for more critical power, flexible cooling options and just-in-time IT capacity are also changing. Today, traditional data centers with 60-100kW and 10-12 racks may no longer be sufficient, highlighting the importance and relevance of modular data centers that can meet the dynamic needs of today’s enterprises. Amid these challenges, businesses may consider prefabricated modular solutions (PFM) and chilled water systems as more suitable options.

Use chilled water systems to accommodate high-density computing

Thermal management is an important pillar of successful data center operations. Effective thermal management not only ensures equipment reliability but also addresses issues such as cost control, operational savings and environmental sustainability.

In the past, thermal management in data centers has been dominated by direct expansion (DX) cooling units, also known as computer room air conditioners or CRAC units. These devices remove heat from the air through a vapor compression cycle. However, the market is now looking for alternative solutions that improve operational efficiency and energy efficiency, such as chilled water systems.

Chilled water systems use water instead of air for cooling. These solutions are also based on vapor compression, but often include free cooling capabilities and achieve greater overall efficiency through a wider range of centralized components outside of the white space.

In chilled water systems, refrigerant is stored in refrigeration units with pretested circuits to prevent leaks. Monitoring systems can detect leaks during operation and help prevent refrigerant loss. Chilled water systems can use other refrigerants with less impact on the atmosphere, including hydrofluoroolefins (HFO) and HFO blends.

 

Data Center Chilled Water System

 

Advantages of Chilled Water Systems

Chilled water systems offer several combined benefits, and this solution will become the dominant global cooling technology for data centers for the foreseeable future. These advantages include its inherent large-scale efficiency, the ability to take advantage of lower ambient air temperatures for free cooling, and reduced environmental impact through environmentally friendly refrigerants. These features enhance operational capabilities and align with global sustainability goals, making chilled water systems a strategic choice for future-proof data center operations.

1. Reduce carbon emissions

Chilled water systems can use low global warming potential (GWP) refrigerant types such as HFO to reduce direct emissions. To illustrate the environmental benefits of these refrigerants, let’s look at their impact on two common chillers:

Small and medium-sized data center chillers have traditionally used R410A (GWP1924), and alternatives such as natural refrigerants such as R454B (GWP466), R32 (GWP677) or R290 are now available.

Medium and large data centers have historically used chillers with screw, or centrifugal compressors to cool their equipment, using R134a coolant with a GWP of 1300. Now, they are switching to coolants such as R513A, which has a GWP of 573, or R1234ze, which has a GWP of less than 1, to reduce their environmental impact.

Chilled water systems therefore offer a more efficient alternative to traditional cooling methods and reduce direct emissions without requiring significant investments or changes to existing data center layouts.

Chilled water systems can also reduce indirect emissions by improving energy efficiency, potentially supporting partial power usage effectiveness (pPUE) below 1.1. With growing concerns about global warming and environmental sustainability, some regions are now mandating such thermal solutions.

2. Enhance data center security and flexibility

In addition to sustainability, the design of the system also deserves attention, especially given concerns about the flammability of modern refrigerants. Chilled water systems have the advantage of placing the cooling units outside the data center, mitigating any type of risk associated with the facility’s flammable refrigerants.

Additionally, chilled water systems offer inherent flexibility in outdoor cooling unit placement. Chilled water systems have no fixed configuration requirements and physical limitations and can be adapted to a variety of operational needs.

3. Improve continuity

What’s more, the chilled water system provides a strong continuity measure, utilizing auxiliary cold water storage tanks to enhance thermal reserves during power outages, ensuring uninterrupted cooling to maintain optimal operating conditions. With these multiple benefits, chilled water systems are a reliable and effective solution to meet the ever-changing demands of contemporary data center environments.

Chilled water systems are also available in non-raised floor designs, providing the flexibility to add liquid cooling to existing data centers. This is an emerging requirement for high-density computing needs that is gaining more and more attention over time.

4. The preferred solution for high-density support

Due to its reliability, scalability and enhanced thermal capacity, chilled water is used in a wide range of applications including telecommunications, government, energy/utilities, security, manufacturing and science. Chilled water is becoming the cooling method of choice for large-scale and high-performance computing applications.

 

Model One: 15 ~ 150kW

ModeloZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Gama de temperaturas +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Água de arrefecimento5 ℃ ~ 30 ℃ Adote a válvula reguladora Siemens / Honeywell para controlar o fluxo de água de resfriamento
Precisão do controlo da temperatura±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
controlo do fluxo10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
O controlo do fluxo é ajustado por conversor de frequência, a precisão é de ±0,3L/min
Capacidade de arrefecimento (MAX)15kW25kW50kW75kW100kW150kW
Volume de armazenamento15L30L60L100L150L200L
SalmouraÁgua, óleo de silicone, líquido fluorado, solução aquosa de etilenoglicol, etc.
controladorPLC, fuzzy PID control algorithm, with cascade control algorithm
temperature controlHeat transfer medium outlet temperature control mode, with cascade control algorithm
letter of agreementInterface Ethernet Protocolo TCP/IP
Interface RS485 protocolo modbus RTU
Device Internal Temperature FeedbackEquipment heat transfer medium outlet temperature, medium inlet temperature, cooling water temperature
tank levelImport and export pressure sensor detection, cooling water pressure detection
Conduta médiaSUS304SUS304SUS304SUS304SUS304SUS304
Heat ExchangerPlate heat exchanger, special attention: need to use clean factory water
operation panelEcrã tátil a cores de 7 polegadas personalizado pela Wuxi Guanya, visualização da curva de temperatura\EXCEL exportação de dados
SegurançaWith self-diagnosis function; phase sequence and phase failure protector; pressure protection, overload relay, thermal protection device and other safety protection functions.
Tamanho da interface de entrada e saídaG3/4G1G1DN32DN40DN50
Interface da água de arrefecimentoG3/4G1DN40DN50DN50DN65
cooling methodWater-cooled, the factory water temperature is lower than the minimum temperature provided by the equipment by more than 3°C, and the water temperature fluctuation is ≤3°C
Fluxo de água de arrefecimento 7~20℃2,5m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
power supply
380V 50HZ 1kW1.5kW3kW4kW5kW6kW
conchaChapas laminadas a frio em spray RAL7035

 

Model Two: 200 ~ 500kW

ModeloZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Gama de temperaturas +5℃~35℃
Precisão da temperatura±0.5℃
Controlo do fluxo15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Flow control is adjusted by frequency converter
Capacidade de arrefecimento(MAX) 200kW250kW300kW400kW500kW
Volume de armazenamento250L300L600L1000L1200L
Cooling SystemThe plant service water exchanges heat with the brine, and the brine provides cooling capacity for the heating equipment
MédioÁgua, óleo de silicone, líquido fluorado, solução aquosa de etilenoglicol, etc.
controladorPLC, fuzzy PID control algorithm, with cascade control algorithm
temperature controlHeat transfer medium outlet temperature control mode式
letter of agreementInterface Ethernet Protocolo TCP/IP
Interface RS485 protocolo modbus RTU
Device Internal Temperature FeedbackEquipment heat transfer medium outlet temperature, medium inlet temperature, cooling water temperature
tank levelPressure sensor real-time monitoring
Conduta médiaSUS304
System pressureUsing the pressure sensor to detect and display on the touch screen
Heat ExchangerPlate heat exchanger, special attention: need to use clean factory water
operation panelEcrã tátil a cores de 7 polegadas personalizado pela Wuxi Guanya, visualização da curva de temperatura\EXCEL exportação de dados
SegurançaWith self-diagnosis function; phase sequence and phase failure protector; pressure protection, overload relay, thermal protection device and other safety protection functions.
Tamanho da interface de entrada e saídaDN65DN65DN65DN80DN80
Interface da água de arrefecimentoDN80DN80DN100DN100DN125
cooling methodWater-cooled, the factory water temperature is lower than the minimum temperature provided by the equipment by more than 3°C, and the water temperature fluctuation is ≤3°C
Fluxo de água de arrefecimento 7~20℃34m³/h43m³/h51m³/h69m³/h86m³/h
Fonte de alimentação 380V 50HZ7kW7kW8kW9kW13kW
conchaChapas laminadas a frio em spray RAL7035

 

unidade de distribuição de refrigeração

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Pedir um orçamento
Nome
Endereço de e-mail
Telefone
Empresa
Preencha os requisitos do seu produto
展开更多
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água