Heater Chiller Circulator
The use effect and operation process of the heater chiller circulator are inseparable from the pre-installation and environmental factors. When using the heater chiller circulator, you also need to pay attention to some precautions.
First, the installation precautions of the heater chiller circulator:
1. The heater chiller circulator has certain conditions for the environment. It is recommended to place it on a firm, stable, level ground with a certain amount of space around it to facilitate the heat dissipation of the equipment, as well as for later repairs or maintenance.
2. The power supply of the heater chiller circulator generally uses three-phase four-wire. If there is an unconventional model, you need to pay attention to distinguish it. Prepare the power supply, zero connection, grounding and other lines in advance to ensure that the connection is tight.
3. Equipped with various overload protections, do not modify it by yourself to cause malfunction.
4. When the heater chiller circulator is being hoisted, care must be taken on site not to cause the equipment to be impacted and damage the display screen while moving.
5. Pay attention to avoid places with dangerous flammable gases and places with acid solutions, and avoid the influence of high-frequency equipment products.
6. The heater chiller circulator should be placed in a dry environment to avoid equipment damage due to high ambient temperature.
Second, precautions for using the heater chiller circulator:
1. The heater chiller circulator will be issued with a product manual when it leaves the factory. Users need to have a certain understanding of the various interfaces, buttons, and screens around the device before operating it. During the use of the equipment, it is necessary to use it strictly in accordance with the equipment manual, and operate according to the use and maintenance, otherwise it will affect the service life of the equipment.
2. Before using the heater chiller circulator, it is necessary to check whether the equipment is in a normal state, and it is necessary to formulate a maintenance plan.
3. When selecting the heat transfer medium of the heater chiller circulator, it is necessary to pay attention to whether its temperature range meets the requirements of the working conditions of the project and whether it is suitable for the use of the equipment. The heat conduction medium needs to be replaced regularly after long-term use. It is recommended to use the same type of medium to avoid equipment blockage caused by heat conduction medium of different models and different brands.
4. There are many types of pipes in the heater chiller circulator. Choose which material is suitable according to the temperature requirements of the equipment model, and then choose according to the length and diameter. It is necessary to regularly check the consumption of the pipes, check whether there is damage, and replace them in time.
냉난방 시스템(SUNDI 시리즈)
온도 제어 범위: -120°C ~ +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
온도 범위 | -40 ~ +200°C 시리즈 | -10 ~ +200°C 시리즈 | -25 ~ +200°C 시리즈 | -25 ~ +300°C 시리즈 | -45 ~ +250°C 시리즈 | -45 ~ +300°C 시리즈 | -60 ~ +250°C 시리즈 | -60 ~ +300°C 시리즈 | -70 ~ +250°C 시리즈 | -80 ~ +250°C 시리즈 | -90 ~ +250°C 시리즈 | -100 ~ +100°C 시리즈 | -25 ~ +200°C, 원자로 두 대용 장비 한 대 | -40 ~ +200°C, 원자로 두 대용 장비 한 대 |
냉각 용량 | 최대 3kW | 최대 15kW | 최대 200kW | 최대 200kW | 최대 200kW | 최대 25kW | 최대 60kW | 최대 25kW | 최대 15kW | 최대 80kW | 최대 80kW | 최대 80kW | 최대 10*2kW | 최대 10*2kW |
냉각 및 난방 시스템(WTD 시리즈)
(마이크로 채널/튜브 리액터 전문)
온도 제어 범위: -70°C ~ +300°C
마이크로 채널에 특화된 설계(작은 액체 보유 용량, 강력한 열 교환 용량, 순환 시스템 고압 강하)
온도 범위 | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
냉각 용량 | up to 7.5kW | up to 5.5kW | 최대 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
온도 범위 | -45°C ~ +250°C 시리즈 | -85°C ~ +200°C 시리즈 | -60°C ~ +200°C 시리즈 |
냉각 용량 | 최대 25kW | 최대 25kW | 최대 60kW |
Cooling and Heating Machines (LTS series)
온도 제어 범위: -80°C ~ +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
온도 범위 | -20°C ~ +80°C 시리즈 | -45°C ~ +80°C 시리즈 | -60°C ~ +80°C 시리즈 | -80°C ~ +80°C 시리즈 |
흐름 제어 | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
냉각 및 난방 서큘레이터
온도 제어 범위: -45°C ~ +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
온도 범위 | -25°C ~ +200°C 시리즈 | -45°C ~ +250°C 시리즈 |
냉각 용량 | 최대 15kW | 최대 15kW |
난방 서큘레이터
온도 제어 범위: +50°C ~ +300°C
참고: UC 시리즈는 열전달 매체의 온도를 제어할 수 있습니다. UST 시리즈는 열 전달 매체의 온도를 제어할 수 있을 뿐만 아니라 반응 물질의 온도도 제어할 수 있습니다.
온도 범위 | +50°C ~ +200°C (UC series) | +50°C ~ +300°C(UC 시리즈) | +50°C ~ +300°C(UST 시리즈) |
난방 용량 | 최대 38kW | 최대 200kW | 최대 95kW |
TCU 멀티 리액터 온도 제어 시스템
온도 제어 범위: -120°C ~ +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
온도 범위 | -45°C ~ +250°C 시리즈 | -120°C ~ +250°C 시리즈 | 맞춤형 온도 제어 시스템 | RT+10°C ~ +135°C |
난방 용량 | 최대 80kW | 최대 80kW | 사용자 지정 | up to 300kW |