In the pharmaceutical and chemical industry, the 12kw chiller is the most used refrigeration equipment, and it is often used in various reactors for refrigeration reactions. In order to maintain the stable operation of the equipment, the precautions before and after starting up the 12kw chiller deserve the attention of users.
First, the 12kw chiller is used before starting up
1. Placement environment: 12kw chiller must keep the equipment vertically upward when moving. Provide a stable anchorage to ensure that the equipment does not tip over. Make sure that the distance between the surrounding walls and the rear panel of the equipment is more than 70CM, and ensure that there is enough ventilation to allow the 12kw chiller to dissipate heat in time under high operating conditions.
2. Attention points for matching connection: check the tightness of the connection pipe interface between the 12kw chiller and peripheral equipment. Enclosed applications with external equipment (such as reactors) need to ensure that the material and performance of the oil delivery line match the heat transfer oil and temperature range. In order to ensure the correct operation of the 12kw chiller, it is necessary to ensure that no air bubbles remain in the system, and ensure that the outlet of the heat transfer medium is connected to the lower interface of the reactor, and the inlet of the heat transfer medium is connected to the upper interface of the reactor. Do not place objects on the device.
3. Adding refrigerant: 12kw chiller will not produce a large amount of leakage for no special reason. If a certain amount of refrigerant leaks due to improper use or after maintenance, it is necessary to add refrigerant again. When charging the refrigerant, pay attention to the type of refrigerant used by the equipment.
4. Filling with heat transfer fluid: water is not allowed as a heat transfer medium. For the steps of adding liquid, please refer to the operation instructions for emptying and adding liquid. When the equipment is in trial operation, check the working conditions of each part for abnormal phenomena and noises.
Second, the 12kw chiller is in use at startup
1. The 12kw chiller has done the above preparations before starting up, and after filling the heat transfer medium and exhausting it, set the temperature and turn on the operation button to start the temperature control.
2. When starting up, pay attention to whether the temperature, pressure, liquid level, hydraulic pressure, air pressure, electrical system, air pressure system, instrument signal and other protections of the 12kw chiller are normal. If there is any abnormality, it should be stopped immediately for inspection until the cause is found out and the problem is eliminated.
Third, 12kw chiller after stop
1. Before the 12kw chiller is running and shutting down, wait for the equipment to return to normal temperature;
2. Power off through the program: click the “Stop” button in the main control window, and after the components stop working completely, you can directly power off.
3. When the 12kw chiller stops working, all joysticks, etc. should be placed in the non-working position, and the electrical control switches, knobs, etc. should be restored to the off state, and the power supply should be cut off.
4. The 12kw chiller needs to be clean and free from dirt, the processed parts are stored neatly, and there is no leakage at the joints of the transmission pipes.
5. If the 12kw chiller does not work for a long time, and the ambient temperature of the equipment should be lower than 0°C, the accumulated water in the system will easily cause the condenser parts to crack. Prevent pipes from rusting or cracking, resulting in damage to the condenser. And discharge the heat transfer medium inside the equipment.
During the use of the 12kw chiller, regular maintenance should be carried out to maintain the accuracy and performance of the equipment as much as possible and prolong the service life.

 

カスタマイズされたソリューション


 

低温チラー

低温チラー(水冷式・空冷式)

温度制御範囲:-150℃~-5

当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。

温度範囲 -25°C ~ -5°Cシリーズ -45°C ~ -10°Cシリーズ -60°C ~ -10°Cシリーズ -80°C ~ -30°Cシリーズ -110°C ~ -50°Cシリーズ
冷却能力最大360kW最大360kW最大360kW270kWまで180kWまで

 


循環式冷凍機

循環式チラー (水冷・空冷)

温度制御範囲:-120℃~+30

私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。

温度範囲 -25°C ~ +30°Cシリーズ -45°C ~ +30°Cシリーズ -60°C ~ -20°Cシリーズ -80°C ~ -20°Cシリーズ -120°C ~ -70°Cシリーズ
冷却能力最大38kW最大12kW最大7.2kW最大7.2kW最大8.6kW

 


ウォーターチラー

室温チラー/小型チラー

温度制御範囲+5℃〜+50

チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。

温度範囲 -18°C ~ +30°C +5°C ~ +35°Cシリーズ
冷却能力0.9kWまで最大50kW

 


直接冷却機

 

直接冷却式冷凍機

温度制御範囲:-120℃~-10

熱交換面積が小さく、熱交換が大きい場所に適している。

 

温度範囲 -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
コンプレッサーパワー8HPまで最大8HP*245HP*3まで

 


 

直接冷却式超低温チラー

温度制御範囲:-150℃~-110

お客様のビジネスにカスタマイズされたソリューションを提供します。

 

温度範囲 -150°C〜-110°C
冷却能力最大11kW

 


スクリュー冷凍機

 

スクリュー冷凍機

低温スクリュー冷凍機と常温スクリュー冷凍機

お客様のビジネスにカスタマイズされたソリューションを提供します。

 

 

温度範囲 +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
冷却能力最大1027kW(シングルコンプレッサー)最大2134kW(デュアルコンプレッサー)最大934kW(シングルコンプレッサー)最大1940kW(デュアルコンプレッサー)最大467kW(シングルコンプレッサー)最大497kW(シングルコンプレッサー)

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
無料見積もりプラン

ロード...

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー