Chiller 12kw – Laboratory Chiller

KlassifizierungIndustrie-Nachrichten 148

Chiller 12kw – Laboratory Chiller

 

In the pharmaceutical and chemical industry, the 12kw chiller is the most used refrigeration equipment, and it is often used in various reactors for refrigeration reactions. In order to maintain the stable operation of the equipment, the precautions before and after starting up the 12kw chiller deserve the attention of users.
First, the 12kw chiller is used before starting up
1. Placement environment: 12kw chiller must keep the equipment vertically upward when moving. Provide a stable anchorage to ensure that the equipment does not tip over. Make sure that the distance between the surrounding walls and the rear panel of the equipment is more than 70CM, and ensure that there is enough ventilation to allow the 12kw chiller to dissipate heat in time under high operating conditions.
2. Attention points for matching connection: check the tightness of the connection pipe interface between the 12kw chiller and peripheral equipment. Enclosed applications with external equipment (such as reactors) need to ensure that the material and performance of the oil delivery line match the heat transfer oil and temperature range. In order to ensure the correct operation of the 12kw chiller, it is necessary to ensure that no air bubbles remain in the system, and ensure that the outlet of the heat transfer medium is connected to the lower interface of the reactor, and the inlet of the heat transfer medium is connected to the upper interface of the reactor. Do not place objects on the device.
3. Adding refrigerant: 12kw chiller will not produce a large amount of leakage for no special reason. If a certain amount of refrigerant leaks due to improper use or after maintenance, it is necessary to add refrigerant again. When charging the refrigerant, pay attention to the type of refrigerant used by the equipment.
4. Filling with heat transfer fluid: water is not allowed as a heat transfer medium. For the steps of adding liquid, please refer to the operation instructions for emptying and adding liquid. When the equipment is in trial operation, check the working conditions of each part for abnormal phenomena and noises.
Second, the 12kw chiller is in use at startup
1. The 12kw chiller has done the above preparations before starting up, and after filling the heat transfer medium and exhausting it, set the temperature and turn on the operation button to start the temperature control.
2. When starting up, pay attention to whether the temperature, pressure, liquid level, hydraulic pressure, air pressure, electrical system, air pressure system, instrument signal and other protections of the 12kw chiller are normal. If there is any abnormality, it should be stopped immediately for inspection until the cause is found out and the problem is eliminated.
Third, 12kw chiller after stop
1. Before the 12kw chiller is running and shutting down, wait for the equipment to return to normal temperature;
2. Power off through the program: click the “Stop” button in the main control window, and after the components stop working completely, you can directly power off.
3. When the 12kw chiller stops working, all joysticks, etc. should be placed in the non-working position, and the electrical control switches, knobs, etc. should be restored to the off state, and the power supply should be cut off.
4. The 12kw chiller needs to be clean and free from dirt, the processed parts are stored neatly, and there is no leakage at the joints of the transmission pipes.
5. If the 12kw chiller does not work for a long time, and the ambient temperature of the equipment should be lower than 0°C, the accumulated water in the system will easily cause the condenser parts to crack. Prevent pipes from rusting or cracking, resulting in damage to the condenser. And discharge the heat transfer medium inside the equipment.
During the use of the 12kw chiller, regular maintenance should be carried out to maintain the accuracy and performance of the equipment as much as possible and prolong the service life.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


 

Niedertemperaturkühler

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperaturregelbereich: -150°C bis -5°C

Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°C Serie -110°C ~ -50°C
Kühlleistungbis zu 360 kWbis zu 360 kWbis zu 360 kWbis zu 270kWbis zu 180kW

 


Umwälzkühler

Rückkühler (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.

Temperaturbereich Serie -25°C ~ +30°C -45°C ~ +30°C Reihe Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistungbis zu 38kWbis zu 12kWbis zu 7,2 kWbis zu 7,2 kWbis zu 8,6 kW

 


Kaltwassersatz

Raumtemperatur-Kühlgeräte / Kleinkühlgeräte

Temperaturregelbereich: +5°C bis +50°C

Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.

Temperaturbereich -18°C ~ +30°C +5°C ~ +35°C Reihe
Kühlleistungbis zu 0,9 kWbis zu 50kW

 


Direktkühlende Maschine

 

Kühlgeräte mit direkter Kühlung

Temperature Control Range: -120°C to -10°C

Er eignet sich für Orte mit kleiner Wärmeaustauschfläche und großem Wärmeaustausch.

 

Temperaturbereich -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Leistung des Kompressorsbis zu 8HPbis zu 8HP*2bis zu 45HP*3

 


 

Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperaturbereich -150°C ~ -110°C
Kühlleistungbis zu 11kW

 


Schrauben-Kühlanlagen

 

Schrauben-Kühlmaschinen

Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen

Customized solutions for your business.

 

 

Temperaturbereich +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Kühlleistungup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz