Chiller 10kw – Low Temperature Chillers
As a kind of industrial equipment, the 10 kw chiller will have some problems after a long time of use. The most serious situation is the sudden shutdown of the equipment. Once this situation cannot be effectively resolved, it may lead to serious accidents. Now let me show you how to deal with the sudden shutdown of the 10 kw chiller?
1. A sudden power outage caused the 10 kw chiller to shut down
During the operation of the refrigeration compressor, if there is a sudden power failure, first disconnect the main power switch, immediately close the suction valve and discharge valve of the compressor, then close the liquid supply gate valve, stop the liquid supply to the evaporator, and prevent the next operation of the 10 kw chiller , the humidity of the evaporator shrinks due to too much liquid.
2. The sudden water cut off caused the shutdown of the 10 kw chiller.
If the refrigeration circulating water is cut off suddenly, the switching power supply should be cut off immediately, and the operation of the refrigeration compressor should be stopped to prevent the working pressure of the equipment from being too high. After the air compressor stops, the suction and exhaust valves and related liquid supply valves should be closed immediately. After the cause is found out and common faults are eliminated, the power supply should be repaired and then restarted.
3. Shutdown caused by common faults of 10 kw chiller compressor
When the compressor is shut down due to damage to a part of the compressor during operation, it can be operated as a normal shutdown if conditions permit. In case of emergency, disconnect the motor switch power supply, and then close the suction, exhaust valve and liquid supply gate valve.
4. Downtime caused by fire
When a fire broke out in an adjacent building, the performance stability of the 10 kw chiller was seriously threatened. The user needs to turn off the power, quickly open the exhaust valves of the liquid storage tank, refrigerator, filter, evaporator, etc., quickly open the emergency ammonia unloader and water inlet valve, so that the solution of the system software is discharged at the emergency unloading port, and use a large amount of water Dilute to prevent fire accidents from spreading and causing accidents.
低温チラー(水冷式・空冷式)
温度制御範囲:-150℃~-5
当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。
温度範囲 | -25°C ~ -5°Cシリーズ | -45°C ~ -10°Cシリーズ | -60°C ~ -10°Cシリーズ | -80°C ~ -30°Cシリーズ | -110°C ~ -50°Cシリーズ |
冷却能力 | 最大360kW | 最大360kW | 最大360kW | 270kWまで | 180kWまで |
循環式チラー (水冷・空冷)
温度制御範囲:-120℃~+30
私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。
温度範囲 | -25°C ~ +30°Cシリーズ | -45°C ~ +30°Cシリーズ | -60°C ~ -20°Cシリーズ | -80°C ~ -20°Cシリーズ | -120°C ~ -70°Cシリーズ |
冷却能力 | 最大38kW | 最大12kW | 最大7.2kW | 最大7.2kW | 最大8.6kW |
室温チラー/小型チラー
温度制御範囲+5℃〜+50
チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。
温度範囲 | -18°C ~ +30°C | +5°C ~ +35°Cシリーズ |
冷却能力 | 0.9kWまで | 最大50kW |
直接冷却式冷凍機
温度制御範囲:-120℃~-10
熱交換面積が小さく、熱交換が大きい場所に適している。
温度範囲 | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
コンプレッサーパワー | 8HPまで | 最大8HP*2 | 45HP*3まで |
直接冷却式超低温チラー
温度制御範囲:-150℃~-110
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | -150°C〜-110°C |
冷却能力 | 最大11kW |
スクリュー冷凍機
低温スクリュー冷凍機と常温スクリュー冷凍機
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
冷却能力 | 最大1027kW(シングルコンプレッサー) | 最大2134kW(デュアルコンプレッサー) | 最大934kW(シングルコンプレッサー) | 最大1940kW(デュアルコンプレッサー) | 最大467kW(シングルコンプレッサー) | 最大497kW(シングルコンプレッサー) |