Chiller Heating and Cooling System
Chiller heating and cooling system is suitable for connecting reaction kettles for refrigeration and heating reactions in pharmaceutical, chemical and laboratory industries, especially our SUNDI series is mainly used for heating and cooling of glass reactors and metal reactors control.
First, the industry application of chiller heating and cooling system:
1. Pharmaceuticals: synthesis, hydrolysis, esterification, etherification and other processes that require temperature control.
2. Chemical industry: rectification and purification, rubber crushing, cryogenic grinding, chemical synthesis.
3. Electronics: environmental testing of parts and components, simulation testing of electronic components.
4. Aerospace: heat sink experiment, component environment simulation test, evaporative cold environment simulation test.
Second, the definition of chiller heating and cooling system:
It is a device that uses heat-conducting medium for dynamic temperature control of fluid refrigeration and heating. It is used in high-precision industries such as pharmaceuticals, chemicals, and semiconductors to help customers complete process temperature control equipment. It is equipped with biochemical test equipment such as reaction kettles, distillation, evaporators, and rotary evaporators. Carry out cooling and heating control of heat transfer medium or reaction material.
Third, the advantages of chiller heating and cooling system
High-temperature cooling technology, which can directly cool down at a high temperature of 300°C, fully closed circulation system, single medium temperature control, temperature: -90°C~250°C high-precision intelligent temperature control, temperature control accuracy: ±0.5°C. Multifunctional alarm system and reliable function, magnetic circulation pump, no shaft seal, solve the leakage problem of circulation pump.
Fourth, what reactions can the chiller heating and cooling system be used for:
Used in polymerization, crystallization, oxidation reaction, catalytic hydrogenation reaction (hydrogenation reaction), nitration reaction, fluorination reaction, chlorination reaction, bromination reaction, epoxidation reaction, heavy ammoniation reaction, helium reaction, hydrolysis reaction, polymerization reaction, photocatalytic oxidation reaction, rearrangement reaction, Michael addition reaction, peroxide preparation reaction, methylation reaction, low temperature reaction, Grignard reaction, epichlorohydrin preparation reaction, cyclization reaction, condensation reaction, Photocatalytic addition reaction, multi-step reaction series reaction, coupling reaction, acylation reaction, acid-base reaction, polymerization reaction, polymer synthesis, low molecular synthesis, crystallization, recrystallization
Fifth, what working conditions do you need to provide when choosing a chiller heating and cooling system?
Temperature range, what field it is used in, what it is used for, temperature control accuracy, heating and cooling rate, cooling capacity, size, material, quantity of supporting reactor, reactor material.
Soluciones personalizadas para su empresa
Sistemas de refrigeración y calefacción (serie SUNDI)
Rango de control de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -40 ~ +200°C | Serie -10 ~ +200°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | -25 ~ +200°C una máquina para dos reactores | -40 ~ +200°C una máquina para dos reactores |
Capacidad de refrigeración | hasta 3 kW | hasta 15 kW | hasta 200 kW | hasta 200 kW | hasta 200 kW | hasta 25 kW | hasta 60 kW | hasta 25 kW | hasta 15 kW | hasta 80 kW | hasta 80 kW | hasta 80 kW | hasta 10*2 kW | hasta 10*2 kW |
Sistemas de refrigeración y calefacción (serie WTD)
(Microcanales / reactores tubulares especializados)
Rango de control de temperatura: de -70°C a +300°C
Diseño especializado para microcanal (pequeña capacidad de retención de líquido, gran capacidad de intercambio de calor, sistema de circulación de alta caída de presión)
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidad de refrigeración | up to 7.5kW | up to 5.5kW | hasta 50 kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperatura | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Capacidad de refrigeración | hasta 25 kW | hasta 25 kW | hasta 60 kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperatura | Serie -20°C ~ +80°C | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Control de caudal | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de refrigeración y calefacción
Rango de control de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C |
Capacidad de refrigeración | hasta 15 kW | hasta 15 kW |
Termostatos de circulación
Rango de control de temperatura: +50°C a +300°C
Nota: La serie UC puede controlar la temperatura del medio de transferencia de calor. La serie UST no solo puede controlar la temperatura del medio de transferencia de calor, sino también la temperatura del material de reacción.
Temperatura | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (serie UC) | +50°C ~ +300°C (serie UST) |
Capacidad de calefacción | hasta 38 kW | hasta 200 kW | hasta 95 kW |
TCU Sistema de control de temperatura multirreactores
Rango de control de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C |
Capacidad de calefacción | hasta 80 kW | hasta 80 kW | A medida | up to 300kW |