Chiller Heating and Cooling System
Chiller heating and cooling system is suitable for connecting reaction kettles for refrigeration and heating reactions in pharmaceutical, chemical and laboratory industries, especially our SUNDI series is mainly used for heating and cooling of glass reactors and metal reactors control.
First, the industry application of chiller heating and cooling system:
1. Pharmaceuticals: synthesis, hydrolysis, esterification, etherification and other processes that require temperature control.
2. Chemical industry: rectification and purification, rubber crushing, cryogenic grinding, chemical synthesis.
3. Electronics: environmental testing of parts and components, simulation testing of electronic components.
4. Aerospace: heat sink experiment, component environment simulation test, evaporative cold environment simulation test.
Second, the definition of chiller heating and cooling system:
It is a device that uses heat-conducting medium for dynamic temperature control of fluid refrigeration and heating. It is used in high-precision industries such as pharmaceuticals, chemicals, and semiconductors to help customers complete process temperature control equipment. It is equipped with biochemical test equipment such as reaction kettles, distillation, evaporators, and rotary evaporators. Carry out cooling and heating control of heat transfer medium or reaction material.
Third, the advantages of chiller heating and cooling system
High-temperature cooling technology, which can directly cool down at a high temperature of 300°C, fully closed circulation system, single medium temperature control, temperature: -90°C~250°C high-precision intelligent temperature control, temperature control accuracy: ±0.5°C. Multifunctional alarm system and reliable function, magnetic circulation pump, no shaft seal, solve the leakage problem of circulation pump.
Fourth, what reactions can the chiller heating and cooling system be used for:
Used in polymerization, crystallization, oxidation reaction, catalytic hydrogenation reaction (hydrogenation reaction), nitration reaction, fluorination reaction, chlorination reaction, bromination reaction, epoxidation reaction, heavy ammoniation reaction, helium reaction, hydrolysis reaction, polymerization reaction, photocatalytic oxidation reaction, rearrangement reaction, Michael addition reaction, peroxide preparation reaction, methylation reaction, low temperature reaction, Grignard reaction, epichlorohydrin preparation reaction, cyclization reaction, condensation reaction, Photocatalytic addition reaction, multi-step reaction series reaction, coupling reaction, acylation reaction, acid-base reaction, polymerization reaction, polymer synthesis, low molecular synthesis, crystallization, recrystallization
Fifth, what working conditions do you need to provide when choosing a chiller heating and cooling system?
Temperature range, what field it is used in, what it is used for, temperature control accuracy, heating and cooling rate, cooling capacity, size, material, quantity of supporting reactor, reactor material.
Soluzioni personalizzate per la vostra azienda
Sistemi di raffreddamento e riscaldamento (serie SUNDI)
Intervallo di controllo della temperatura: da -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Intervallo di temperatura | Serie -40 ~ +200°C | Serie -10 ~ +200°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | -25 ~ +200°C una macchina per due reattori | -40 ~ +200°C una macchina per due reattori |
Capacità di raffreddamento | fino a 3kW | fino a 15kW | fino a 200kW | fino a 200kW | fino a 200kW | fino a 25kW | fino a 60kW | fino a 25kW | fino a 15kW | fino a 80kW | fino a 80kW | fino a 80kW | fino a 10*2kW | fino a 10*2kW |
Sistemi di raffreddamento e riscaldamento (serie WTD)
(Micro reattori a canale/tubo specializzati)
Intervallo di controllo della temperatura: da -70°C a +300°C
Design specializzato per il microcanale (piccola capacità di contenimento del liquido, forte capacità di scambio termico, elevata perdita di carico del sistema di circolazione)
Intervallo di temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacità di raffreddamento | up to 7.5kW | up to 5.5kW | fino a 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Intervallo di temperatura | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Capacità di raffreddamento | fino a 25kW | fino a 25kW | fino a 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Intervallo di temperatura | Serie -20°C ~ +80°C | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Controllo del flusso | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circolatori di raffreddamento e riscaldamento
Intervallo di controllo della temperatura: da -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Intervallo di temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C |
Capacità di raffreddamento | fino a 15kW | fino a 15kW |
Circolatori di riscaldamento
Intervallo di controllo della temperatura: Da +50°C a +300°C
Nota: la serie UC può controllare la temperatura del mezzo di trasferimento del calore. La serie UST può controllare non solo la temperatura del mezzo di trasferimento del calore, ma anche quella del materiale di reazione.
Intervallo di temperatura | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (serie UC) | +50°C ~ +300°C (serie UST) |
Capacità di riscaldamento | fino a 38kW | fino a 200kW | fino a 95kW |
TCU Sistema di controllo della temperatura dei multireattori
Intervallo di controllo della temperatura: da -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Intervallo di temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema di controllo della temperatura personalizzato | RT+10°C ~ +135°C |
Capacità di riscaldamento | fino a 80kW | fino a 80kW | Personalizzato | up to 300kW |