Water Cooled Water Chiller System

ClassificationIndustry News 149

Water Cooled Water Chiller System

 

The installation of water cooled water chiller system can be carried out from four aspects, the first is the installation of the chiller, then the installation of the water pipes, the cleaning of the water pipes and the insulation of the unit. Don’t underestimate the installation part, it will directly affect whether the water cooled water chiller system can run safely and stably. Let’s briefly talk about the four main points of installation.

1. Installation of water cooled water chiller system: The equipment must be installed in a flat and open place, and the chiller is no exception. Before installing the chiller, many users will do the foundation watering and pre-bury four horizontal horns. Generally, the water chiller has four feet. You can prepare an adjustment backing plate with two adjustment threaded holes for the feet to adjust the level of the entire water cooled water chiller system, and pour concrete mortar into the excess after adjustment. gap. After the mortar is dry, the adjusting bolts can be removed, leaving the positioning bolts, and fixing measures are taken for the chiller.

2. Installation of water cooled water chiller system water pipes: mainly the external water pipes of the evaporator and condenser. If it is a double-return water pipe, it should be arranged on the same side. The inlet and outlet water of the condenser and evaporator of the cooled water chiller system are from the bottom to the top. Remarks: From the cooling water tower to the chiller, from the chiller to the equipment to be cooled, water will be transported through the water pump in the middle, so the installation of the water pipes must be carried out according to the installation diagram provided by the manufacturer.

3. Cleaning of water cooled water chiller system water pipes: After installing the water pipes to the unit, perform a leak test for the entire water system. After passing the leak test, you can clean the water pipes. When cleaning the water pipe, first confirm whether the direction of the water pump is correct, and open all the valves of the water inlet and outlet pipes, the pipes are completely filled with water, start the chilled water pump and the cooling water pump, and stop the water pump after two hours of continuous operation. Drain the cooling water and clean the water pump filter.

4. Insulation of water cooled water chiller system: When the temperature in the unit system is lower than the ambient temperature, there will be a loss of cooling capacity. In order to reduce this loss, it is recommended that the user wrap a layer of heat insulation material on the low temperature part of the equipment and pipeline. When the water cooled water chiller system is installed and the system pressure test is carried out, the evaporator shell or evaporator water tank, compressor inlet pipe, return water pipe, etc. shall be insulated.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller