検索 すべて検索

Water Cooled Water Chiller System

分類業界ニュース 155

Water Cooled Water Chiller System

 

The installation of water cooled water chiller system can be carried out from four aspects, the first is the installation of the chiller, then the installation of the water pipes, the cleaning of the water pipes and the insulation of the unit. Don’t underestimate the installation part, it will directly affect whether the water cooled water chiller system can run safely and stably. Let’s briefly talk about the four main points of installation.

1. Installation of water cooled water chiller system: The equipment must be installed in a flat and open place, and the chiller is no exception. Before installing the chiller, many users will do the foundation watering and pre-bury four horizontal horns. Generally, the water chiller has four feet. You can prepare an adjustment backing plate with two adjustment threaded holes for the feet to adjust the level of the entire water cooled water chiller system, and pour concrete mortar into the excess after adjustment. gap. After the mortar is dry, the adjusting bolts can be removed, leaving the positioning bolts, and fixing measures are taken for the chiller.

2. Installation of water cooled water chiller system water pipes: mainly the external water pipes of the evaporator and condenser. If it is a double-return water pipe, it should be arranged on the same side. The inlet and outlet water of the condenser and evaporator of the cooled water chiller system are from the bottom to the top. Remarks: From the cooling water tower to the chiller, from the chiller to the equipment to be cooled, water will be transported through the water pump in the middle, so the installation of the water pipes must be carried out according to the installation diagram provided by the manufacturer.

3. Cleaning of water cooled water chiller system water pipes: After installing the water pipes to the unit, perform a leak test for the entire water system. After passing the leak test, you can clean the water pipes. When cleaning the water pipe, first confirm whether the direction of the water pump is correct, and open all the valves of the water inlet and outlet pipes, the pipes are completely filled with water, start the chilled water pump and the cooling water pump, and stop the water pump after two hours of continuous operation. Drain the cooling water and clean the water pump filter.

4. Insulation of water cooled water chiller system: When the temperature in the unit system is lower than the ambient temperature, there will be a loss of cooling capacity. In order to reduce this loss, it is recommended that the user wrap a layer of heat insulation material on the low temperature part of the equipment and pipeline. When the water cooled water chiller system is installed and the system pressure test is carried out, the evaporator shell or evaporator water tank, compressor inlet pipe, return water pipe, etc. shall be insulated.

 

カスタマイズされたソリューション


 

低温チラー

低温チラー(水冷式・空冷式)

温度制御範囲:-150℃~-5

当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。

温度範囲 -25°C ~ -5°Cシリーズ -45°C ~ -10°Cシリーズ -60°C ~ -10°Cシリーズ -80°C ~ -30°Cシリーズ -110°C ~ -50°Cシリーズ
冷却能力最大360kW最大360kW最大360kW270kWまで180kWまで

 


循環式冷凍機

循環式チラー (水冷・空冷)

温度制御範囲:-120℃~+30

私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。

温度範囲 -25°C ~ +30°Cシリーズ -45°C ~ +30°Cシリーズ -60°C ~ -20°Cシリーズ -80°C ~ -20°Cシリーズ -120°C ~ -70°Cシリーズ
冷却能力最大38kW最大12kW最大7.2kW最大7.2kW最大8.6kW

 


ウォーターチラー

室温チラー/小型チラー

温度制御範囲+5℃〜+50

チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。

温度範囲 -18°C ~ +30°C +5°C ~ +35°Cシリーズ
冷却能力0.9kWまで最大50kW

 


直接冷却機

 

直接冷却式冷凍機

温度制御範囲:-120℃~-10

熱交換面積が小さく、熱交換が大きい場所に適している。

 

温度範囲 -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
コンプレッサーパワー8HPまで最大8HP*245HP*3まで

 


 

直接冷却式超低温チラー

温度制御範囲:-150℃~-110

お客様のビジネスにカスタマイズされたソリューションを提供します。

 

温度範囲 -150°C〜-110°C
冷却能力最大11kW

 


スクリュー冷凍機

 

スクリュー冷凍機

低温スクリュー冷凍機と常温スクリュー冷凍機

お客様のビジネスにカスタマイズされたソリューションを提供します。

 

 

温度範囲 +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
冷却能力最大1027kW(シングルコンプレッサー)最大2134kW(デュアルコンプレッサー)最大934kW(シングルコンプレッサー)最大1940kW(デュアルコンプレッサー)最大467kW(シングルコンプレッサー)最大497kW(シングルコンプレッサー)