Cooler Heater
The correct debugging of the cooler heater is related to the operation of the entire equipment. For the cooling and heating system of the cooler heater, it is necessary to make preparations before debugging and cooperate closely to avoid misoperation of the equipment.
Since the cooler heater is a medium-to-large equipment, it requires close cooperation in design, installation, and use during commissioning. In order to ensure that the commissioning work is carried out in an orderly manner, it is necessary to form a temporary trial operation team with relevant personnel to fully command the commissioning work.
The personnel in charge of commissioning should be fully familiar with the structure and performance of the cooler heater, familiar with the safety technology of the refrigerator, clarify the debugging methods, steps and technical requirements to be met, formulate a detailed and specific commissioning plan, and let the commissioning personnel in each position clarify their own tasks and requirements.
Check whether the installation of the cooler heater meets the technical requirements, whether the foundation meets the requirements, and whether the size, specification, and material of the connecting pipeline meet the design requirements.
The power supply system of the cooler heater should be completely installed and passed the debugging. Carry out a water flow test on the refrigeration system alone, flush the dirt in the water system, the water pump should work normally, and the circulating water volume meets the requirements of the working conditions.
Clean up the environment where the cooler heater is debugged to achieve a clean, bright, and unimpeded flow. Prepare various general tools and special tools required for debugging, and prepare various measuring instruments such as pressure, temperature, flow, quality, and time for debugging, Instruments, prepare the necessary safety protection equipment for commissioning and operation.
After the cooler heater is ready for commissioning, professional commissioning personnel will conduct commissioning, and carefully read the operating instructions provided by the manufacturer before commissioning.
Soluções personalizadas para o seu negócio
Sistemas de arrefecimento e aquecimento (série SUNDI)
Gama de controlo de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -40 ~ +200°C | Série -10 ~ +200°C | Série -25 ~ +200°C | Série -25 ~ +300°C | Série -45 ~ +250°C | Série -45 ~ +300°C | Série -60 ~ +250°C | Série -60 ~ +300°C | Série -70 ~ +250°C | Série -80 ~ +250°C | Série -90 ~ +250°C | Série -100 ~ +100°C | -25 ~ +200°C uma máquina para dois reactores | -40 ~ +200°C uma máquina para dois reactores |
Capacidade de arrefecimento | até 3kW | até 15kW | até 200kW | até 200kW | até 200kW | até 25kW | até 60kW | até 25kW | até 15kW | até 80kW | até 80kW | até 80kW | até 10*2kW | até 10*2kW |
Sistemas de arrefecimento e aquecimento (série WTD)
(Reactores de canal micro / tubo especializados)
Gama de controlo de temperatura: -70°C a +300°C
Design especializado para micro canal (pequena capacidade de retenção de líquido, forte capacidade de troca de calor, sistema de circulação de alta queda de pressão)
Gama de temperaturas | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidade de arrefecimento | up to 7.5kW | up to 5.5kW | até 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Gama de temperaturas | Série -45°C ~ +250°C | Série -85°C ~ +200°C | Série -60°C ~ +200°C |
Capacidade de arrefecimento | até 25kW | até 25kW | até 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Gama de temperaturas | Série -20°C ~ +80°C | Série -45°C ~ +80°C | Série -60°C ~ +80°C | Série -80°C ~ +80°C |
Controlo do fluxo | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de arrefecimento e aquecimento
Gama de controlo de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -25°C ~ +200°C | Série -45°C ~ +250°C |
Capacidade de arrefecimento | até 15kW | até 15kW |
Circuladores de aquecimento
Gama de controlo de temperatura: +50°C a +300°C
Nota: A série UC pode controlar a temperatura do meio de transferência de calor. A série UST pode não só controlar a temperatura do meio de transferência de calor, mas também controlar a temperatura do material de reação.
Gama de temperaturas | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (série UC) | +50°C ~ +300°C (série UST) |
Capacidade de aquecimento | até 38kW | até 200kW | até 95kW |
TCU Sistema de controlo da temperatura de multi-reactores
Gama de controlo de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -45°C ~ +250°C | Série -120°C ~ +250°C | Sistema de controlo de temperatura personalizado | RT+10°C ~ +135°C |
Capacidade de aquecimento | até 80kW | até 80kW | Personalizado | up to 300kW |