Ricerca Cerca tutti

Cooler Heater

ClassificazioneNotizie sul settore 255

Cooler Heater

 

The correct debugging of the cooler heater is related to the operation of the entire equipment. For the cooling and heating system of the cooler heater, it is necessary to make preparations before debugging and cooperate closely to avoid misoperation of the equipment.

Since the cooler heater is a medium-to-large equipment, it requires close cooperation in design, installation, and use during commissioning. In order to ensure that the commissioning work is carried out in an orderly manner, it is necessary to form a temporary trial operation team with relevant personnel to fully command the commissioning work.

The personnel in charge of commissioning should be fully familiar with the structure and performance of the cooler heater, familiar with the safety technology of the refrigerator, clarify the debugging methods, steps and technical requirements to be met, formulate a detailed and specific commissioning plan, and let the commissioning personnel in each position clarify their own tasks and requirements.

Check whether the installation of the cooler heater meets the technical requirements, whether the foundation meets the requirements, and whether the size, specification, and material of the connecting pipeline meet the design requirements.

The power supply system of the cooler heater should be completely installed and passed the debugging. Carry out a water flow test on the refrigeration system alone, flush the dirt in the water system, the water pump should work normally, and the circulating water volume meets the requirements of the working conditions.

Clean up the environment where the cooler heater is debugged to achieve a clean, bright, and unimpeded flow. Prepare various general tools and special tools required for debugging, and prepare various measuring instruments such as pressure, temperature, flow, quality, and time for debugging, Instruments, prepare the necessary safety protection equipment for commissioning and operation.

After the cooler heater is ready for commissioning, professional commissioning personnel will conduct commissioning, and carefully read the operating instructions provided by the manufacturer before commissioning.

 

Soluzioni personalizzate per la vostra azienda


Sistemi di raffreddamento e riscaldamento (serie SUNDI)

Intervallo di controllo della temperatura: da -120°C a +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Intervallo di temperatura Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C una macchina per due reattori -40 ~ +200°C una macchina per due reattori
Capacità di raffreddamentofino a 3kWfino a 15kWfino a 200kWfino a 200kWfino a 200kWfino a 25kWfino a 60kWfino a 25kWfino a 15kWfino a 80kWfino a 80kWfino a 80kWfino a 10*2kWfino a 10*2kW

 


Sistemi di raffreddamento e riscaldamento (serie WTD)

(Micro reattori a canale/tubo specializzati)

Intervallo di controllo della temperatura: da -70°C a +300°C

Design specializzato per il microcanale (piccola capacità di contenimento del liquido, forte capacità di scambio termico, elevata perdita di carico del sistema di circolazione)

 

Intervallo di temperatura -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Capacità di raffreddamentoup to 7.5kWup to 5.5kWfino a 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Intervallo di temperatura Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Capacità di raffreddamentofino a 25kWfino a 25kWfino a 60kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Intervallo di temperatura Serie -20°C ~ +80°C Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Controllo del flusso7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Circolatori di raffreddamento e riscaldamento

Intervallo di controllo della temperatura: da -45°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Intervallo di temperatura Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Capacità di raffreddamentofino a 15kWfino a 15kW

 


Circolatori di riscaldamento

Intervallo di controllo della temperatura: Da +50°C a +300°C

Nota: la serie UC può controllare la temperatura del mezzo di trasferimento del calore. La serie UST può controllare non solo la temperatura del mezzo di trasferimento del calore, ma anche quella del materiale di reazione.

Intervallo di temperatura +50°C ~ +200°C  (UC series) +50°C ~ +300°C (serie UC) +50°C ~ +300°C (serie UST)
Capacità di riscaldamentofino a 38kWfino a 200kWfino a 95kW

 


TCU Sistema di controllo della temperatura dei multireattori

Intervallo di controllo della temperatura: da -120°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Intervallo di temperatura Serie -45°C ~ +250°C Serie -120°C ~ +250°CSistema di controllo della temperatura personalizzatoRT+10°C ~ +135°C
Capacità di riscaldamentofino a 80kWfino a 80kWPersonalizzatoup to 300kW

 

Le informazioni sul copyright appartengono a lneya-online.com, si prega di contattare l'e-mail per i dettagli: lilia@lneya.com

Oppure scansionate il codice QR di WhatsApp o WeChat qui sotto per contattarci. 

WhatsAPP WeChat

scansione

Precedente: Il prossimo:
Ottenere un preventivo gratuito Piano

caricamento...

购物车

X

我的足迹

X
parole chiave: parole chiaveGioia in bottiglia refrigeratore d'acqua