During the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect of the glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of the glycol chiller, the glycol chiller manufacturer suggests that you should carry out necessary daily maintenance.

  1. Inspection of refrigeration system of glycol chiller

Generally, after the glycol water chiller is used for a long time, it is inevitable that various problems or faults will occur. We should carefully check the working conditions of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system to judge whether they are in normal operation. It is usually checked by sound and appearance. If there are problems, it is recommended to replace the parts in time.

  1. Refrigerant inspection of glycol chiller

Regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of ethylene glycol chiller will also be different. When the ethylene glycol chiller works normally, the high pressure display is 11-17kg and the low pressure display is 3-5kg.

  1. Inspection of cooling water system of glycol chiller

Check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.

  1. Cleaning of glycol chiller system

When the glycol chiller is used for six months, the system shall be cleaned once a year. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure better refrigeration effect.

  1. Voltage and current inspection of glycol chiller

Regularly check whether the voltage and electric flow of the glycol chiller are stable and whether the compressor operation sound is normal. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.

We are a professional manufacturer of chillers and temperature control equipment, supporting customized services, please ご相談ください 詳細はこちら!

 


Low Temperature Glycol Chillers

温度制御範囲:-150℃~-5

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

温度範囲 -25°C ~ -5°Cシリーズ -45°C ~ -10°Cシリーズ -60°C ~ -10°Cシリーズ -80°C ~ -30°Cシリーズ -110°C ~ -50°Cシリーズ -150℃〜-110℃シリーズ
冷却能力最大360kW最大360kW最大360kW270kWまで180kWまで最大11kW

 


Glycol Recirculating Chillers

Temperature Control Range: -120°C to 30°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

 

温度範囲 -25°C ~ 30°C series -45°C ~ 30°C series -60°C ~ -20°Cシリーズ -80°C ~ -20°Cシリーズ -120°C ~ -70°Cシリーズ
冷却能力最大38kW最大12kW最大7.2kW最大7.2kW最大8.6kW

 


Normal Temperature Glycol Chillers

温度制御範囲+5℃〜+50

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

 

温度範囲 -18°C ~ +30°C +5°C ~ +50°C series
冷却能力0.9kWまで最大50kW

 


Cooling and Heating Glycol Chillers

温度制御範囲:-120°C~+350°C

用途各種リアクター(マイクロチャンネル、ガラス、ジャケット付きリアクターなど)、蒸留または抽出システム、研究室、大学、研究所、航空宇宙、自動車産業、半導体および電気テスト、化学、製薬、石油化学、生化学、医療、病院、研究開発ワークショップ、航空宇宙、生物学およびその他の産業。

温度範囲 -40 ~ +200℃シリーズ -10 ~ +200℃シリーズ -25 ~ +200℃シリーズ -25 ~ +300℃シリーズ -45 ~ +250°C シリーズ -45 ~ +300℃シリーズ -60 ~ +250°C シリーズ -60 ~ +300℃シリーズ -70 ~ +250°C シリーズ -80 ~ +250°C シリーズ-90 ~ +250°C シリーズ -100 ~ +100℃シリーズ -25 ~ +200°C 1台で2台のリアクターに対応 -40 ~ +200°C 1台で2台のリアクターに対応
冷却能力3kWまで15kWまで200kWまで200kWまで200kWまで最大25kW60kWまで最大25kW15kWまで最大80kW最大80kW最大80kW最大10*2kW最大10*2kW

 


Glycol Cooling and Heating Circulators

温度制御範囲:-45℃~+250

用途各種リアクター(マイクロチャンネル、ガラス、ジャケット付きリアクターなど)、蒸留または抽出システム、研究室、大学、研究所、航空宇宙、化学、製薬、石油化学、生化学、医療、病院、研究開発ワークショップ、航空宇宙、生物学、その他の産業。

温度範囲 -25°C ~ +200°Cシリーズ -45°C ~ +250°C シリーズ
冷却能力15kWまで15kWまで