Buscar en Buscar todos

Suggestions on Daily Maintenance of Glycol Chiller

ClasificaciónNoticias del sector 217

 

Suggestions on Daily Maintenance of Glycol Chiller

 

During the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect of the glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of the glycol chiller, the glycol chiller manufacturer suggests that you should carry out necessary daily maintenance.

  1. Inspection of refrigeration system of glycol chiller

Generally, after the glycol water chiller is used for a long time, it is inevitable that various problems or faults will occur. We should carefully check the working conditions of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system to judge whether they are in normal operation. It is usually checked by sound and appearance. If there are problems, it is recommended to replace the parts in time.

  1. Refrigerant inspection of glycol chiller

Regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of ethylene glycol chiller will also be different. When the ethylene glycol chiller works normally, the high pressure display is 11-17kg and the low pressure display is 3-5kg.

  1. Inspection of cooling water system of glycol chiller

Check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.

  1. Cleaning of glycol chiller system

When the glycol chiller is used for six months, the system shall be cleaned once a year. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure better refrigeration effect.

  1. Voltage and current inspection of glycol chiller

Regularly check whether the voltage and electric flow of the glycol chiller are stable and whether the compressor operation sound is normal. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.

We are a professional manufacturer of chillers and temperature control equipment, supporting customized services, please consúltenos para más detalles

 


Low Temperature Glycol Chillers

Rango de control de temperatura: -150°C a -5°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperatura Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°C Serie -110°C ~ -50°C Serie -150°C ~ -110°C
Capacidad de refrigeraciónhasta 360 kWhasta 360 kWhasta 360 kWhasta 270 kWhasta 180 kWhasta 11 kW

 


Glycol Recirculating Chillers

Temperature Control Range: -120°C to 30°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

 

Temperatura -25°C ~ 30°C series -45°C ~ 30°C series Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Capacidad de refrigeraciónhasta 38 kWhasta 12 kWhasta 7,2 kWhasta 7,2 kWhasta 8,6 kW

 


Normal Temperature Glycol Chillers

Rango de control de temperatura: +5°C a +50°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

 

Temperatura -18°C ~ +30°C +5°C ~ +50°C series
Capacidad de refrigeraciónhasta 0,9 kWhasta 50 kW

 


Cooling and Heating Glycol Chillers

Rango de control de temperatura: -120°C a +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperatura Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C una máquina para dos reactores -40 ~ +200°C una máquina para dos reactores
Capacidad de refrigeraciónhasta 3 kWhasta 15 kWhasta 200 kWhasta 200 kWhasta 200 kWhasta 25 kWhasta 60 kWhasta 25 kWhasta 15 kWhasta 80 kWhasta 80 kWhasta 80 kWhasta 10*2 kWhasta 10*2 kW

 


Glycol Cooling and Heating Circulators

Rango de control de temperatura: -45°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperatura Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Capacidad de refrigeraciónhasta 15 kWhasta 15 kW

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Obtener presupuesto gratuito

cargando...

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua