Search Search all

How to Improve the Cooling Effect of the Chiller?

ClassificationIndustry News 496

 

How to Improve the Cooling Effect of the Chiller?

 

In the process of using industrial chillers, the most important thing is the cooling effect. However, some users have recently reported that in the process of using the chiller, sometimes the cooling effect is not ideal, which will affect everyone’s normal use. The following LNEYA refrigeration manufacturer will explain to you how to solve the problem of unsatisfactory cooling effect of the chiller?

The cooling effect of the chiller is not ideal, you can start from the following four aspects:

1. Regularly check the compressor:

The compressor is the “heart” of the industrial chiller, and its quality directly affects the stability of the chiller when it is used. If the compressor fails to be repaired, the repair cost will be relatively high, especially for screw compressors. Therefore, in daily operation, if you hear abnormal sound from the compressor or other conditions, you should contact the chiller manufacturer in time to find a professional engineer to check, find out the cause and carry out maintenance.

2. Periodically clean the condenser and evaporator:

The condenser and evaporator are the second most important components of the chiller, and experts recommend cleaning it every six months. The cooling water of the water-cooled condenser is an open circulation loop. The tap water used is recycled through the cooling water tower, which is easy to decompose and deposit impurities on the water pipe to form scale, which affects the heat transfer effect. Over time, the scaling will be too thick and the cooling water circulation section will be reduced, resulting in a reduction in water volume and an increase in condensing pressure.

3. Regularly change the lubricating oil:

After the chiller is used for a long time, the oil quality of the lubricating oil will deteriorate, and the impurities and moisture inside the oil will increase, so it is necessary to observe and check the oil quality regularly. Once a problem is found, it should be replaced in time. The recommended replacement lubrication should be based on the original manufacturer.

4. Periodically replace the filter drier:

The filter drier is an important part to ensure the normal circulation of the refrigerant. Since water and refrigerant are immiscible with each other, if the system contains moisture, it will affect the operation efficiency of the chiller. Therefore, it is very important to keep the inside of the system dry. The filter element should be replaced regularly.

We are a professional manufacturer of temperature control equipment, supporting customized services, please consult us for details!

 


Low Temperature Chillers

Temperature Control Range: -150°C to -5°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kWup to 11kW

 


Recirculating Chillers

Temperature Control Range: -120°C to 30°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ 30°C series -45°C ~ 30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


Normal Temperature Chillers

Temperature Control Range: +5°C to +50°C

Application: Various Reactors, Distillation or Extraction System, Laboratory, Research Institute, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Semiconductor Test, Aerospace, Biological and Other Industries.

Temperature range -18°C ~ +30°C +5°C ~ +50°C series
Cooling Capacityup to 0.9kWup to 50kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller