Buscar en Buscar todos

Packaged Air Cooled Chiller

ClasificaciónNoticias del sector 143

Packaged Air Cooled Chiller

 

The packaged air cooled chiller is one of the models and specifications of the chiller. It cools the water at room temperature to a certain temperature according to the refrigeration compressor of the chiller to strengthen the cooling model or equipment. It is used as a stand-alone version, and the heat pipe is built-in. The cooling fan, packaged air cooled chiller mainly has three interconnected systems: refrigerant circulation, water circulation system, and automatic control system. The key structure of packaged air cooled chiller are: condenser, liquid storage.

The basic composition of packaged air cooled chiller:

1. Condenser:
In the refrigeration process, the condenser plays the role of outputting energy and cooling the refrigerant. After the high-pressure super-temperature steam discharged from the refrigeration unit enters the condenser, it absorbs all the heat absorbed during the working process, including the heat absorbed from the air-conditioning evaporator and refrigeration unit as well as in the pipeline. The heat absorbed is transferred to the surrounding substances; the high-pressure superheated steam of the refrigerant condenses into a liquid again. According to the different cooling substances and cooling methods, condensers can be divided into three categories: water-cooled condensers, air-cooled condensers, and volatile condensers.

2. Liquid reservoir:
After the liquid receiver is installed in the condenser, it is immediately connected with the liquid outlet pipe of the condenser. The refrigerant liquid of the condenser should be injected into the liquid receiver unimpeded, so that the cooling area of the condenser can be fully utilized. On the other hand, when the heat consumption of the air-conditioning evaporator changes, the demand for refrigerant liquid also changes. At that time, the liquid receiver has the function of regulating and storing refrigerant. For small and medium-sized chiller refrigeration systems, there is usually no liquid receiver, but a condenser is used to adjust and store the refrigerant.

3. Dry filter device:
In the refrigeration cycle of the packaged air cooled chiller, it is necessary to prevent moisture and waste from entering. The source of moisture is mainly a small amount of moisture contained in the newly added refrigerant and grease, or due to the gas entering during system maintenance. produced moisture. If the water in the system is not cleaned, when the refrigerant passes through the overflow valve, the water will sometimes condense and freeze due to the drop in pressure and temperature, which will block the passage and affect the normal operation of the refrigeration equipment. Therefore, a dry filter must be installed in the chiller.

4. Air conditioner evaporator:
The air conditioner evaporator is a thermal device that uses the volatilization of the refrigerant liquid to digest and absorb the heat generated by the refrigerated substance. Its role in the packaged air cooled chiller is to digest and absorb heat. In order to ensure that the volatilization process can be carried out smoothly and for a long time, it is necessary to continuously use the refrigeration unit to suck away the volatilized gas to maintain a certain volatilization pressure.

5. Expansion valve:
The expansion valve is the regulating valve of the total flow in the packaged air cooled chiller, and it is also the overflow valve in the refrigeration equipment. It is installed between the dry filter device and the air conditioner evaporator in the equipment, and its temperature sensor package is bundled in the air conditioner evaporator. The entrance and exit of the device. Its key function is to make the refrigerant liquid under high pressure and normal temperature flow through the expansion valve to lower blood pressure during the season, turn into ultra-low temperature and low pressure refrigerant wet steam, enter the air conditioner evaporator, gasify and absorb heat in the air conditioner evaporator, and achieve cooling and cooling purpose.

6. Refrigerant:
Most of the industrial chillers used in the industry use R22 or R12 as the refrigerant. Refrigerant is the fluid steam parameter in the packaged air cooled chiller. Its main function is to carry heat and complete endothermic and exothermic reactions when the situation changes.

The packaged air cooled chiller is used to cool the forming mold of plastic granulation machinery and equipment, which can further improve the surface smoothness of plastic products, reduce the surface marks and thermal stress of plastic products, keep the products from shrinking and deformation, and facilitate the ejection of plastic products. Accelerate the setting of goods, thereby greatly improving the productivity of plastic film blowing machines. The packaged air cooled chiller is used in CNC lathes, coordinate boring machines, CNC grinding machines, CNC machining centers, special machine tools and various fine lathe spindle lubrication and cooling of hydraulic transmission system transmission media. It can accurately control the water temperature and reduce the temperature reasonably. The thermal deformation of the CNC lathe improves the machining accuracy of the CNC lathe.

 

Enfriadoras a medida                                                                                                                  

 

refrigerador de baja temperatura

Refrigeradores de baja temperatura (Diseños a medida)

Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.

Temperatura Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°CSerie -110°C ~ -50°C Serie -150°C ~ -110°C
Capacidad de refrigeración12 ~ 360 kW6 ~ 180 kW6 ~ 180 kW4 ~ 180kW2 ~ 120kW2,5 ~ 11 kW

 


enfriador de recirculación

Enfriadoras de recirculación (Diseños a medida)

Nuestro enfriador de recirculación adopta tecnología de refrigeración de baja temperatura, la temperatura es tan baja como -120℃, y varios accesorios son personalizables.

Temperatura Serie -25°C ~ +30°C Serie -45°C ~ +30°C Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Capacidad de refrigeración0,8 ~ 30 kW0,75 ~ 12 kW0,4 ~ 6kW0,2 ~ 6kW0,3 ~ 5kW

 


enfriador de agua

Refrigeradores de temperatura ambiente / Refrigeradores pequeños (Diseños a medida)

El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.

Temperatura -18°C ~ +30°C Serie +5°C ~ +35°C
Capacidad de refrigeración0,35 ~ 0,9 kW1,8 ~ 50 kW

 


Chillers for Automotive Battery Test (Diseños a medida)

Simulación de temperatura para pruebas de calidad de vehículos: prueba de duración de baterías, banco de pruebas de inyectores/motores de combustible, prueba de airbags, banco de pruebas de componentes, etc.

 

Temperatura -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
Capacidad de refrigeración2,8 ~ 38 kW1,2 ~ 60 kW1,8 ~ 60 kW4 ~ 60kW

 

La temperatura, la presión y el caudal pueden controlarse de forma independiente.

1&2: una máquina para el control de dos grupos.

Temperatura -40 ~ +100℃ 1&20 ~ +100℃ 1&2
Capacidad de refrigeración1,8 kW*2 ~ 60 kW*21,8 kW*2 ~ 60 kW*2

 

La temperatura permanece constante, la presión y el caudal pueden controlarse independientemente.

1&3: una máquina para el control de tres grupos.

1&6: una máquina para el control de seis grupos.

Temperatura -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
Capacidad de refrigeración2,5 ~ 60 kW4 ~ 60kW10 ~ 60 kW10 ~ 60 kW7 ~ 60 kW11 ~ 60kW18 ~ 60 kW

 


Semiconductor Enfriadoras (TES series) (Diseños a medida)

Adecuado para el control preciso de la temperatura de los componentes electrónicos. En la fabricación de componentes electrónicos semiconductores para entornos adversos, las fases de ensamblaje de embalajes de CI y de pruebas de ingeniería y producción incluyen pruebas térmicas electrónicas y otras simulaciones de pruebas ambientales.

Temperatura Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Capacidad de refrigeración0,3 ~ 25 kW0,25 ~ 25 kW3 ~ 60kW

 


Semiconductor Enfriadoras (LTS series) (Diseños a medida)

Adecuado para el control preciso de la temperatura de los componentes electrónicos. En la fabricación de componentes electrónicos semiconductores para entornos adversos, las fases de ensamblaje de embalajes de CI y de pruebas de ingeniería y producción incluyen pruebas térmicas electrónicas y otras simulaciones de pruebas ambientales.

Temperatura Serie -20°C ~ +80°C Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Control de caudal7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


 

Enfriadoras para almacenamiento de energía(Diseños a medida)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

Temperatura -45°C ~ +55°C
Capacidad de refrigeración45 kW

 


refrigeradores de tornillo

 

Refrigeradores de tornillo (Diseños a medida)

Refrigeradores de tornillo de baja temperatura y refrigeradores de tornillo a temperatura ambiente

 

 

Temperatura +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Capacidad de refrigeración107 ~ 1027 kW (compresor único)299 ~ 2134 kW (compresor doble)98 ~ 934 kW (compresor único)272 ~ 1940 kW (compresor doble)48 ~ 467 kW (un compresor)51 ~ 497 kW (compresor único)

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Obtener presupuesto gratuito

cargando...

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua