Pesquisar Pesquisar tudo

Packaged Air Cooled Chiller

ClassificaçãoNotícias do sector 140

Packaged Air Cooled Chiller

 

The packaged air cooled chiller is one of the models and specifications of the chiller. It cools the water at room temperature to a certain temperature according to the refrigeration compressor of the chiller to strengthen the cooling model or equipment. It is used as a stand-alone version, and the heat pipe is built-in. The cooling fan, packaged air cooled chiller mainly has three interconnected systems: refrigerant circulation, water circulation system, and automatic control system. The key structure of packaged air cooled chiller are: condenser, liquid storage.

The basic composition of packaged air cooled chiller:

1. Condenser:
In the refrigeration process, the condenser plays the role of outputting energy and cooling the refrigerant. After the high-pressure super-temperature steam discharged from the refrigeration unit enters the condenser, it absorbs all the heat absorbed during the working process, including the heat absorbed from the air-conditioning evaporator and refrigeration unit as well as in the pipeline. The heat absorbed is transferred to the surrounding substances; the high-pressure superheated steam of the refrigerant condenses into a liquid again. According to the different cooling substances and cooling methods, condensers can be divided into three categories: water-cooled condensers, air-cooled condensers, and volatile condensers.

2. Liquid reservoir:
After the liquid receiver is installed in the condenser, it is immediately connected with the liquid outlet pipe of the condenser. The refrigerant liquid of the condenser should be injected into the liquid receiver unimpeded, so that the cooling area of the condenser can be fully utilized. On the other hand, when the heat consumption of the air-conditioning evaporator changes, the demand for refrigerant liquid also changes. At that time, the liquid receiver has the function of regulating and storing refrigerant. For small and medium-sized chiller refrigeration systems, there is usually no liquid receiver, but a condenser is used to adjust and store the refrigerant.

3. Dry filter device:
In the refrigeration cycle of the packaged air cooled chiller, it is necessary to prevent moisture and waste from entering. The source of moisture is mainly a small amount of moisture contained in the newly added refrigerant and grease, or due to the gas entering during system maintenance. produced moisture. If the water in the system is not cleaned, when the refrigerant passes through the overflow valve, the water will sometimes condense and freeze due to the drop in pressure and temperature, which will block the passage and affect the normal operation of the refrigeration equipment. Therefore, a dry filter must be installed in the chiller.

4. Air conditioner evaporator:
The air conditioner evaporator is a thermal device that uses the volatilization of the refrigerant liquid to digest and absorb the heat generated by the refrigerated substance. Its role in the packaged air cooled chiller is to digest and absorb heat. In order to ensure that the volatilization process can be carried out smoothly and for a long time, it is necessary to continuously use the refrigeration unit to suck away the volatilized gas to maintain a certain volatilization pressure.

5. Expansion valve:
The expansion valve is the regulating valve of the total flow in the packaged air cooled chiller, and it is also the overflow valve in the refrigeration equipment. It is installed between the dry filter device and the air conditioner evaporator in the equipment, and its temperature sensor package is bundled in the air conditioner evaporator. The entrance and exit of the device. Its key function is to make the refrigerant liquid under high pressure and normal temperature flow through the expansion valve to lower blood pressure during the season, turn into ultra-low temperature and low pressure refrigerant wet steam, enter the air conditioner evaporator, gasify and absorb heat in the air conditioner evaporator, and achieve cooling and cooling purpose.

6. Refrigerant:
Most of the industrial chillers used in the industry use R22 or R12 as the refrigerant. Refrigerant is the fluid steam parameter in the packaged air cooled chiller. Its main function is to carry heat and complete endothermic and exothermic reactions when the situation changes.

The packaged air cooled chiller is used to cool the forming mold of plastic granulation machinery and equipment, which can further improve the surface smoothness of plastic products, reduce the surface marks and thermal stress of plastic products, keep the products from shrinking and deformation, and facilitate the ejection of plastic products. Accelerate the setting of goods, thereby greatly improving the productivity of plastic film blowing machines. The packaged air cooled chiller is used in CNC lathes, coordinate boring machines, CNC grinding machines, CNC machining centers, special machine tools and various fine lathe spindle lubrication and cooling of hydraulic transmission system transmission media. It can accurately control the water temperature and reduce the temperature reasonably. The thermal deformation of the CNC lathe improves the machining accuracy of the CNC lathe.

 

Refrigeradores personalizados                                                                                                                  

 

refrigerador de baixa temperatura

Chillers de baixa temperatura (Desenhos personalizados)

Somos especializados na produção de refrigeradores de baixa temperatura com uma gama de controlo de temperatura tão baixa como -150°C, que pode satisfazer as necessidades de refrigeração de diferentes indústrias.

Gama de temperaturas Série -25°C ~ -5°C Série -45°C ~ -10°C Série -60°C ~ -10°C Série -80°C ~ -30°CSérie -110°C ~ -50°C Série -150°C ~ -110°C
Capacidade de arrefecimento12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2,5 ~ 11kW

 


refrigerador de recirculação

Chillers de recirculação (Desenhos personalizados)

Nosso resfriador de recirculação adota tecnologia de refrigeração de baixa temperatura, a temperatura é tão baixa quanto -120 ℃ e vários acessórios são personalizáveis.

Gama de temperaturas Série -25°C ~ +30°C Série -45°C ~ +30°C Série -60°C ~ -20°C Série -80°C ~ -20°C Série -120°C ~ -70°C
Capacidade de arrefecimento0,8 ~ 30kW0,75 ~ 12kW0,4 ~ 6kW0,2 ~ 6kW0,3 ~ 5kW

 


refrigerador de água

Refrigeradores de temperatura ambiente / Refrigeradores pequenos (Desenhos personalizados)

O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.

Gama de temperaturas -18°C ~ +30°C Série +5°C ~ +35°C
Capacidade de arrefecimento0,35 ~ 0,9kW1,8 ~ 50kW

 


Chillers for Automotive Battery Test (Desenhos personalizados)

Simulação da temperatura para o ensaio da qualidade do veículo: ensaio da duração da bateria, banco de ensaio do injetor/motor de combustível, ensaio do airbag, banco de ensaio de componentes, etc.

 

Gama de temperaturas -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
Capacidade de arrefecimento2,8 ~ 38kW1,2 ~ 60kW1,8 ~ 60kW4 ~ 60kW

 

A temperatura / pressão / caudal podem ser controlados de forma independente.

1&2: uma máquina para controlo de dois grupos.

Gama de temperaturas -40 ~ +100℃ 1&20 ~ +100℃ 1&2
Capacidade de arrefecimento1,8kW*2 ~ 60kW*21,8kW*2 ~ 60kW*2

 

A temperatura mantém-se constante, a pressão / caudal podem ser controlados de forma independente.

1&3: uma máquina para controlo de três grupos.

1&6: uma máquina para controlo de seis grupos.

Gama de temperaturas -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
Capacidade de arrefecimento2,5 ~ 60kW4 ~ 60kW10 ~ 60kW10 ~ 60kW7 ~ 60kW11 ~ 60kW18 ~ 60kW

 


Semicondutores Refrigeradores (TES series) (Desenhos personalizados)

Adequado para o controlo preciso da temperatura de componentes electrónicos. No fabrico de componentes electrónicos de semicondutores para ambientes agressivos, as fases de montagem de embalagens IC e de ensaios de engenharia e produção incluem ensaios térmicos electrónicos e outras simulações de ensaios ambientais.

Gama de temperaturas Série -45°C ~ +250°C Série -85°C ~ +200°C Série -60°C ~ +200°C
Capacidade de arrefecimento0,3 ~ 25kW0,25 ~ 25kW3 ~ 60kW

 


Semicondutores Refrigeradores (LTS series) (Desenhos personalizados)

Adequado para o controlo preciso da temperatura de componentes electrónicos. No fabrico de componentes electrónicos de semicondutores para ambientes agressivos, as fases de montagem de embalagens IC e de ensaios de engenharia e produção incluem ensaios térmicos electrónicos e outras simulações de ensaios ambientais.

Gama de temperaturas Série -20°C ~ +80°C Série -45°C ~ +80°C Série -60°C ~ +80°C Série -80°C ~ +80°C
Controlo do fluxo7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


 

Chillers para armazenamento de energia(Desenhos personalizados)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

Gama de temperaturas -45°C ~ +55°C
Capacidade de arrefecimento45kW

 


refrigeradores de parafuso

 

Chillers de parafuso (Desenhos personalizados)

Refrigeradores de parafuso a baixa temperatura e refrigeradores de parafuso a temperatura ambiente

 

 

Gama de temperaturas +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Capacidade de arrefecimento107 ~ 1027kW (Compressor único)299 ~ 2134kW (Compressor duplo)98 ~ 934kW (Compressor único)272 ~ 1940kW (Compressor duplo)48 ~ 467kW (Compressor único)51 ~ 497kW (Compressor simples)

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água