Packaged Air Cooled Chiller

 

The packaged air cooled chiller is one of the models and specifications of the chiller. It cools the water at room temperature to a certain temperature according to the refrigeration compressor of the chiller to strengthen the cooling model or equipment. It is used as a stand-alone version, and the heat pipe is built-in. The cooling fan, packaged air cooled chiller mainly has three interconnected systems: refrigerant circulation, water circulation system, and automatic control system. The key structure of packaged air cooled chiller are: condenser, liquid storage.

The basic composition of packaged air cooled chiller:

1. Condenser:
In the refrigeration process, the condenser plays the role of outputting energy and cooling the refrigerant. After the high-pressure super-temperature steam discharged from the refrigeration unit enters the condenser, it absorbs all the heat absorbed during the working process, including the heat absorbed from the air-conditioning evaporator and refrigeration unit as well as in the pipeline. The heat absorbed is transferred to the surrounding substances; the high-pressure superheated steam of the refrigerant condenses into a liquid again. According to the different cooling substances and cooling methods, condensers can be divided into three categories: water-cooled condensers, air-cooled condensers, and volatile condensers.

2. Liquid reservoir:
After the liquid receiver is installed in the condenser, it is immediately connected with the liquid outlet pipe of the condenser. The refrigerant liquid of the condenser should be injected into the liquid receiver unimpeded, so that the cooling area of the condenser can be fully utilized. On the other hand, when the heat consumption of the air-conditioning evaporator changes, the demand for refrigerant liquid also changes. At that time, the liquid receiver has the function of regulating and storing refrigerant. For small and medium-sized chiller refrigeration systems, there is usually no liquid receiver, but a condenser is used to adjust and store the refrigerant.

3. Dry filter device:
In the refrigeration cycle of the packaged air cooled chiller, it is necessary to prevent moisture and waste from entering. The source of moisture is mainly a small amount of moisture contained in the newly added refrigerant and grease, or due to the gas entering during system maintenance. produced moisture. If the water in the system is not cleaned, when the refrigerant passes through the overflow valve, the water will sometimes condense and freeze due to the drop in pressure and temperature, which will block the passage and affect the normal operation of the refrigeration equipment. Therefore, a dry filter must be installed in the chiller.

4. Air conditioner evaporator:
The air conditioner evaporator is a thermal device that uses the volatilization of the refrigerant liquid to digest and absorb the heat generated by the refrigerated substance. Its role in the packaged air cooled chiller is to digest and absorb heat. In order to ensure that the volatilization process can be carried out smoothly and for a long time, it is necessary to continuously use the refrigeration unit to suck away the volatilized gas to maintain a certain volatilization pressure.

5. Expansion valve:
The expansion valve is the regulating valve of the total flow in the packaged air cooled chiller, and it is also the overflow valve in the refrigeration equipment. It is installed between the dry filter device and the air conditioner evaporator in the equipment, and its temperature sensor package is bundled in the air conditioner evaporator. The entrance and exit of the device. Its key function is to make the refrigerant liquid under high pressure and normal temperature flow through the expansion valve to lower blood pressure during the season, turn into ultra-low temperature and low pressure refrigerant wet steam, enter the air conditioner evaporator, gasify and absorb heat in the air conditioner evaporator, and achieve cooling and cooling purpose.

6. Refrigerant:
Most of the industrial chillers used in the industry use R22 or R12 as the refrigerant. Refrigerant is the fluid steam parameter in the packaged air cooled chiller. Its main function is to carry heat and complete endothermic and exothermic reactions when the situation changes.

The packaged air cooled chiller is used to cool the forming mold of plastic granulation machinery and equipment, which can further improve the surface smoothness of plastic products, reduce the surface marks and thermal stress of plastic products, keep the products from shrinking and deformation, and facilitate the ejection of plastic products. Accelerate the setting of goods, thereby greatly improving the productivity of plastic film blowing machines. The packaged air cooled chiller is used in CNC lathes, coordinate boring machines, CNC grinding machines, CNC machining centers, special machine tools and various fine lathe spindle lubrication and cooling of hydraulic transmission system transmission media. It can accurately control the water temperature and reduce the temperature reasonably. The thermal deformation of the CNC lathe improves the machining accuracy of the CNC lathe.

 

Kundenspezifische Kühler                                                                                                                  

 

Niedertemperaturkühler

Niedertemperatur-Kühlgeräte (Benutzerdefinierte Designs)

Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°CSerie -110°C ~ -50°C Serie -150°C ~ -110°C
Kühlleistung12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2,5 ~ 11kW

 


Umwälzkühler

Rückkühler (Benutzerdefinierte Designs)

Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.

Temperaturbereich Serie -25°C ~ +30°C -45°C ~ +30°C Reihe Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistung0,8 ~ 30kW0,75 ~ 12kW0,4 ~ 6kW0,2 ~ 6kW0,3 ~ 5kW

 


Kaltwassersatz

Raumtemperatur-Kühlgeräte / Kleinkühlgeräte (Benutzerdefinierte Designs)

Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.

Temperaturbereich -18°C ~ +30°C +5°C ~ +35°C Reihe
Kühlleistung0,35 ~ 0,9kW1,8 ~ 50kW

 


Chillers for Automotive Battery Test (Benutzerdefinierte Designs)

Temperatursimulation für die Qualitätsprüfung von Fahrzeugen: Prüfung der Batterielebensdauer, Prüfstand für Einspritzdüsen/Motoren, Airbag-Prüfung, Komponentenprüfstand, usw.

 

Temperaturbereich -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
Kühlleistung2,8 ~ 38kW1,2 ~ 60kW1.8 ~ 60kW4 ~ 60kW

 

Temperatur/Druck/Durchfluss können unabhängig voneinander geregelt werden.

1&2: eine Maschine für zwei Kontrollgruppen.

Temperaturbereich -40 ~ +100℃ 1&20 ~ +100℃ 1&2
Kühlleistung1.8kW*2 ~ 60kW*21.8kW*2 ~ 60kW*2

 

Die Temperatur bleibt konstant, Druck und Durchfluss können unabhängig voneinander geregelt werden.

1&3: eine Maschine für drei Kontrollgruppen.

1&6: eine Maschine für sechs Kontrollgruppen.

Temperaturbereich -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
Kühlleistung2,5 ~ 60kW4 ~ 60kW10 ~ 60kW10 ~ 60kW7 ~ 60kW11 ~ 60kW18 ~ 60kW

 


Halbleiter Kühlanlagen (TES series) (Benutzerdefinierte Designs)

Geeignet für die präzise Temperaturkontrolle von elektronischen Bauteilen. Bei der Herstellung von elektronischen Halbleiterkomponenten für raue Umgebungen umfassen die Phasen der IC-Gehäusemontage sowie der Entwicklungs- und Produktionstests auch elektronische Wärmetests und andere Simulationen von Umwelttests.

Temperaturbereich Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Kühlleistung0,3 ~ 25kW0,25 ~ 25kW3 ~ 60kW

 


Halbleiter Kühlanlagen (LTS series) (Benutzerdefinierte Designs)

Geeignet für die präzise Temperaturkontrolle von elektronischen Bauteilen. Bei der Herstellung von elektronischen Halbleiterkomponenten für raue Umgebungen umfassen die Phasen der IC-Gehäusemontage sowie der Entwicklungs- und Produktionstests auch elektronische Wärmetests und andere Simulationen von Umwelttests.

Temperaturbereich -20°C ~ +80°C Reihe Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Durchflusskontrolle7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


 

Kältemaschinen für die Energiespeicherung(Benutzerdefinierte Designs)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

Temperaturbereich -45°C ~ +55°C
Kühlleistung45kW

 


Schrauben-Kühlanlagen

 

Schrauben-Kühlmaschinen (Benutzerdefinierte Designs)

Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen

 

 

Temperaturbereich +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Kühlleistung107 ~ 1027kW (Einzelverdichter)299 ~ 2134kW (Doppelkompressor)98 ~ 934kW (Einzelverdichter)272 ~ 1940kW (Doppelkompressor)48 ~ 467kW (Einzelverdichter)51 ~ 497kW (Einzelverdichter)

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz