COP (Coefficient Of Performance) of the Chiller
COP (Coefficient Of Performance) is the ratio of energy conversion efficiency. The greater the energy efficiency ratio, the greater the energy savings. In a refrigeration system, the conversion ratio between the amount of cooling produced and the energy consumed is the energy efficiency ratio, also known as the cooling coefficient.
COP refers to the cooling capacity obtained per unit of power consumption. The value of the energy efficiency ratio reflects the refrigeration efficiency of the chiller and is an important technical and economic indicator of the refrigeration system.
COP is the ratio of the cooling capacity that the chiller can achieve to the input power. Under the same working conditions, the larger the ratio, the higher the efficiency and energy saving of the refrigeration system. The larger the cooling performance coefficient, the higher the energy utilization efficiency of the cooling system.
COP is related to the type of chiller, the type of refrigerant and the operating conditions, and the theoretical refrigeration performance coefficient can reach 2.5 to 5.5. Since this parameter is expressed as the ratio of input power and output power in the same unit, it is a dimensionless number.
Common chillers, COP performance parameters are roughly as follows:
1. Air-cooled or evaporative-cooled chillers (piston chillers, scroll chillers):
When the rated cooling capacity is less than or equal to 50KW, its COP should not be less than 2.40;
When the rated cooling capacity is greater than 50KW, its COP should not be less than 2.60;
2. Piston-type and scroll-type chillers (multi-unit equipment):
When the rated cooling capacity is less than 528KW, its COP should not be less than 3.8;
When the rated cooling capacity is 528~1163KW, its COP should not be less than 4.0;
When the rated cooling capacity is greater than 1163KW, its COP should not be less than 4.2;
3. Air-cooled or evaporative-cooled screw chillers:
When the rated cooling capacity is less than or equal to 50KW, its COP should not be less than 2.60;
When the rated cooling capacity is more than 50KW, its COP should not be less than 2.80;
4. Water-cooled screw chiller:
When the rated cooling capacity is less than 528KW, its COP should not be less than 4.10;
When the rated cooling capacity is 528~1163KW, its COP should not be less than 4.30;
When the rated cooling capacity is greater than 1163KW, its COP should not be less than 4.60;
5. Centrifugal chiller:
When the rated cooling capacity is less than 528KW, its COP should not be less than 4.40;
When the rated cooling capacity is 528~1163KW, its COP should not be less than 4.70;
When the rated cooling capacity is greater than 1163KW, its COP should not be less than 5.10.
For COP of special chillers, please contact us!
Correo electrónico: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Soluciones personalizadas para su empresa
Refrigeradores de baja temperatura (por agua y por aire)
Rango de control de temperatura: -150°C a -5°C
Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.
Temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C |
Capacidad de refrigeración | hasta 360 kW | hasta 360 kW | hasta 360 kW | hasta 270 kW | hasta 180 kW |
Enfriadoras de recirculación (Refrigeración por agua y por aire)
Rango de control de temperatura: -120°C a +30°C
Nuestro enfriador de recirculación adopta tecnología de refrigeración de baja temperatura, la temperatura es tan baja como -120℃, y varios accesorios son personalizables.
Temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Capacidad de refrigeración | hasta 38 kW | hasta 12 kW | hasta 7,2 kW | hasta 7,2 kW | hasta 8,6 kW |
Refrigeradores de temperatura ambiente / Refrigeradores pequeños
Rango de control de temperatura: +5°C a +50°C
El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.
Temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C |
Capacidad de refrigeración | hasta 0,9 kW | hasta 50 kW |
Equipos frigoríficos de refrigeración directa
Rango de control de temperatura: -120°C a -10°C
Es adecuado para lugares con poca superficie de intercambio de calor y gran intercambio de calor.
Temperatura | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Potencia del compresor | hasta 8CV | hasta 8CV*2 | hasta 45 CV*3 |
Enfriadoras de temperatura ultrabaja de refrigeración directa
Rango de control de temperatura: -150°C a -110°C
Soluciones personalizadas para su empresa.
Temperatura | -150°C ~ -110°C |
Capacidad de refrigeración | hasta 11 kW |
Refrigeradores de tornillo
Refrigeradores de tornillo de baja temperatura y refrigeradores de tornillo a temperatura ambiente
Soluciones personalizadas para su empresa.
Temperatura | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidad de refrigeración | hasta 1027 kW (compresor único) | hasta 2134 kW (compresor doble) | hasta 934 kW (compresor único) | hasta 1940 kW (compresor doble) | hasta 467 kW (compresor único) | hasta 497 kW (compresor único) |