Search Search all

Chiller Heating and Cooling System

ClassificationIndustry News 276

Chiller Heating and Cooling System

 

Chiller heating and cooling system is suitable for connecting reaction kettles for refrigeration and heating reactions in pharmaceutical, chemical and laboratory industries, especially our SUNDI series is mainly used for heating and cooling of glass reactors and metal reactors control.

First, the industry application of chiller heating and cooling system:

1. Pharmaceuticals: synthesis, hydrolysis, esterification, etherification and other processes that require temperature control.

2. Chemical industry: rectification and purification, rubber crushing, cryogenic grinding, chemical synthesis.

3. Electronics: environmental testing of parts and components, simulation testing of electronic components.

4. Aerospace: heat sink experiment, component environment simulation test, evaporative cold environment simulation test.

Second, the definition of chiller heating and cooling system:

It is a device that uses heat-conducting medium for dynamic temperature control of fluid refrigeration and heating. It is used in high-precision industries such as pharmaceuticals, chemicals, and semiconductors to help customers complete process temperature control equipment. It is equipped with biochemical test equipment such as reaction kettles, distillation, evaporators, and rotary evaporators. Carry out cooling and heating control of heat transfer medium or reaction material.

Third, the advantages of chiller heating and cooling system

High-temperature cooling technology, which can directly cool down at a high temperature of 300°C, fully closed circulation system, single medium temperature control, temperature: -90°C~250°C high-precision intelligent temperature control, temperature control accuracy: ±0.5°C. Multifunctional alarm system and reliable function, magnetic circulation pump, no shaft seal, solve the leakage problem of circulation pump.

Fourth, what reactions can the chiller heating and cooling system be used for:

Used in polymerization, crystallization, oxidation reaction, catalytic hydrogenation reaction (hydrogenation reaction), nitration reaction, fluorination reaction, chlorination reaction, bromination reaction, epoxidation reaction, heavy ammoniation reaction, helium reaction, hydrolysis reaction, polymerization reaction, photocatalytic oxidation reaction, rearrangement reaction, Michael addition reaction, peroxide preparation reaction, methylation reaction, low temperature reaction, Grignard reaction, epichlorohydrin preparation reaction, cyclization reaction, condensation reaction, Photocatalytic addition reaction, multi-step reaction series reaction, coupling reaction, acylation reaction, acid-base reaction, polymerization reaction, polymer synthesis, low molecular synthesis, crystallization, recrystallization

Fifth, what working conditions do you need to provide when choosing a chiller heating and cooling system?

Temperature range, what field it is used in, what it is used for, temperature control accuracy, heating and cooling rate, cooling capacity, size, material, quantity of supporting reactor, reactor material.

 

Customized Solutions For Your Business


Cooling and Heating Systems (SUNDI series)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -40 ~ +200°C series -10 ~ +200°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacityup to 3kWup to 15kWup to 200kWup to 200kWup to 200kWup to 25kWup to 60kWup to 25kWup to 15kWup to 80kWup to 80kWup to 80kWup to 10*2kWup to 10*2kW

 


Cooling and Heating Systems (WTD series)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacityup to 7.5kWup to 5.5kWup to 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacityup to 25kWup to 25kWup to 60kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Cooling and Heating Circulators

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacityup to 15kWup to 15kW

 


Heating Circulators

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +200°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacityup to 38kWup to 200kWup to 95kW

 


TCU Multi-reactors Temperature Control System

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacityup to 80kWup to 80kWCustomup to 300kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller