Search Search all

Chiller Heater Combo

ClassificationIndustry News 156

Chiller Heater Combo

 

The chiller heater combo is an instrument that can provide cooling and heating fluid temperature control. It uses different media to circulate high temperature and low temperature in the pipeline system. The heat release or absorption will be circulated into the reactor jacket through the circulation pump. Carry out periodic circulation, so that the reactor matching the chiller heater combo can meet the required temperature requirements.

Chiller heater combo is mainly used in combination with double-layer glass reactors, which can provide a circulation device with heat source and cold source, it has a wide range of work, used in pharmaceutical, chemical, biochemical, biological and other industries, for reactors, storage tanks etc. provide a heat source, and a cold source can also be used to heat and cool other equipment.

The chiller heater combo can be equipped with various types of reaction kettles, stirring tanks, etc. for cooling and heating temperature control, and can be used for distillation, extraction, etc. for high and low temperature and ultra-low temperature control to achieve the effect of separation. In addition to the pharmaceutical and chemical industry, our company can also conduct high and low temperature performance tests for the material testing industry, component semiconductor industry, etc.; it can also perform high and low temperature tests for batteries and motors in the new energy industry.

Different models and temperatures of chiller heater combo use different media, including heat transfer oil, water, and ethylene glycol aqueous solution. The chiller heater combo is similar to the mold temperature controllers, high and low temperature all-in-one machines, and all-in-one cooling and heating machines on the market, but the functions, configurations, and parameters of each manufacturer are different.

The chiller heater combo now adopts PID intelligent temperature control technology, which can be heated, constant temperature or cooled. The current temperature control requirement can reach plus or minus 0.5°C (of course, there may be some differences for different models). Our company adopts multi-point temperature control technology , The pipeline and electrical parts can be made of isolation and explosion-proof type, the temperature range is relatively large, and the temperature rise and fall is relatively uniform and stable.

The chiller heater combo needs to be designed and customized by the manufacturer. If the configuration is too low, it will be difficult to achieve the required hot and cold temperatures. Too high cooling temperature and too low heating temperature can easily lead to longer cooling time, and the heat source will affect production efficiency. However, if the chiller heater combo is set too high, it will cause excessive power, causing unnecessary waste and increasing operating costs.

 

Dynamic Temperature Control Systems (Support Customization)               

 

Cooling and Heating Systems (SUNDI series) (Custom Designs)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kWup to 10*2kWup to 10*2kW

 


Cooling and Heating Systems (WTD series) (Custom Designs)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW

 


Cooling and Heating Systems (TES series) (Custom Designs)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacity0.3 ~ 25kW0.25 ~ 25kW3 ~ 60kW

 


Cooling and Heating Machines (LTS series) (Custom Designs)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Cooling and Heating Circulators (Custom Designs)

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW

 


Heating Circulators (Custom Designs)

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +170°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacity5.5 ~ 15kW3.5 ~ 130kW3.5 ~ 95kW

 


TCU Multi-reactors Temperature Control System (Custom Designs)

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller