Customers need to consider many factors when purchasing reactor refrigeration heating temperature control equipment, such as heating power, cycle pressure, cooling capacity, flow rate, etc., and various working conditions require different equipment models.

First, clarify the user’s working conditions:

1. First figure out the temperature range and capacity you need. These two values are also factors that affect the price of the all-in-one cooling and heating machine. Prevent the situation that the purchased equipment cannot reach the operating temperature, or the waste of resources caused by excessive power supply.

2. The power of the equipment. Many users only consider the heat dissipation and cooling of the power supply when purchasing the power supply, but do not care about the power of the water pump. If the power of the pump is lower than the flow rate, it cannot meet the requirements of use. If the power of the water pump is too large, it will cause energy loss and increase the cost of use.

Second, what factors should be considered when choosing temperature control equipment?

1. Determine the basic requirements of the reactor

Users have different requirements for temperature control of reactors, material, quantity, inlet temperature, inlet temperature, and precision requirements. Therefore, the corresponding models and sizes also have certain differences. Users need accurate process data, and choose suitable ones based on these data. model.

2. Determine the model of the reactor refrigeration heating temperature control equipment

The heat transfer oil of the reactor temperature control equipment generally adopts a fixed type of heat transfer oil, and the type of reaction medium can be determined according to the temperature requirements of the reactor. According to their own site conditions, make supporting preparations. For some special environments, the isolated explosion-proof type can also be customized according to the corresponding requirements, and there are corresponding explosion-proof grades.

3. Determine the parameter configuration of the device

After the user provides the manufacturer with accurate operating data, the manufacturer will provide the corresponding cooling and heating temperature control scheme after calculation. In the scheme, the model and parameter configuration will be selected. The user can see the brand of each accessory in the parameter configuration. After the calculation, the corresponding cooling and heating control scheme will be provided. Some accessories have a variety of brands to choose from. If users have requirements, they can contact to modify. Generally, it is a standard configuration, but it can also be customized.

After determining all the parameters, we have to choose the manufacturer. The price is only a unilateral factor, and we should not blindly seek cheap prices. There are many factors to be considered in the selection of reactor temperature control equipment, and the size of the environment where the equipment is placed should also be considered, and the corresponding ventilation position should be reserved for placing the equipment.

 

Dynamic Temperature Control Systems (Support Customization)               

 

Cooling and Heating Systems (SUNDI series) (Custom Designs)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kWup to 10*2kWup to 10*2kW

 


Cooling and Heating Systems (WTD series) (Custom Designs)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW

 


Cooling and Heating Systems (TES series) (Custom Designs)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacity0.3 ~ 25kW0.25 ~ 25kW3 ~ 60kW

 


Cooling and Heating Machines (LTS series) (Custom Designs)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Cooling and Heating Circulators (Custom Designs)

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW

 


Heating Circulators (Custom Designs)

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +170°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacity5.5 ~ 15kW3.5 ~ 130kW3.5 ~ 95kW

 


TCU Multi-reactors Temperature Control System (Custom Designs)

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller