Please Search Dynamic temp. control systems Ultra-Low Temp. Chillers NEV Test Chillers Thermal Test & Process Cooling TCU Unit

ZLF  -45°C ~ +250°C

ZLF -45°C ~ +250°C

  • Temperature Control Range: -45°C ~ +250 °C
  • Temperature Control Accuracy: ±1 °C
  • MODBUS RTU Protocol, RS485 Interface, Optional Ethernet Interface/R232 Interface

Note: Both Air Cooled And Water Cooled Are Available. Explosion Proof Cabinet Can Be Customized.

 

Application: Various Reactors, Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Biological and Other Industries.

 

Request a Quote          Email Us           More Product Models

Product Description

Excellent performance, high precision, intelligent temperature control, very wide temperature control range, from -120 °C ~ 350 °C, suitable for most enterprises temperature control needs. Product temperature control accuracy of ± 0.5 ° C, cooling power from 0.5 kW to 1200 kW can provide the corresponding products.

Temperature Process Control Principle

Through three-point sampling (material temperature point, temperature control system outlet temperature, temperature control system inlet temperature), and our own model-free self-built tree algorithm and general anti-lag cascade algorithm, solve the problem of large delay in pharmaceutical chemical temperature control.

Advantages of TCU:

  • Users can get a closed and repeatable temperature control in a wide temperature range, which can realize temperature control of - 120 ~ 300 ℃.
  • The built-in electric heating heat transfer oil auxiliary system can automatically start the auxiliary heating system according to the demand to reduce the steam pressure.
  • It can accurately match the heat demand through rapid operation to achieve the purpose of energy conservation.
  • The temperature of the whole reaction process is controlled by fast calculation, and the exothermic and endothermic reactions in the whole reaction process are controlled by fast response.
  • A standardized interface is reserved, and the cold and heat source heat exchange module can be added according to the actual demand.
  • The reaction process temperature and single fluid temperature can be selectively controlled, and the temperature difference between the reaction process temperature and single fluid temperature can be set and controlled.
  • Fully enclosed pipeline design is adopted.
  • To ensure the safe operation of the system, the electric valves can be fully opened manually.

Model ZLF-35N
ZLF-35NS
ZLF-35NH
ZLF-35NSH
ZLF-50N
ZLF-50NS
ZLF-50NH
ZLF-50NSH
ZLF-80N
ZLF-80NS
ZLF-80NH
ZLF-80NSH
ZLF-125N
ZLF-125NS
ZLF-125NH
ZLF-125NSH
ZLF-200N
ZLF-200NS
ZLF-200NH
ZLF-200NSH
Temp. range ℃ -45~ 250degree (setting the max temp according to the supplier heating or cooling source)
-40~135degree(The maximum temperature range can be operated by using glycol water formula.)
ZLF-  N The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled.
ZLF-  NS Besides ZLF- N function,add one set heater used to reduce high temp.
ZLF-  NH Besides ZLF- N function,add electrical heating function
ZLF-  NSH Besides ZLF- N function,add one set heater used to reduce high temp and electrical heating function
Heat exchanger area 3.5m2 5m2 8m2 12.5m2 20m2
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temp control selection Process temp control
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Process temp. feedback Raw material process feedback:PT100 or 4~20mA or communication given
Temp. feedback:PT100
temp feedback: normal PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 150L/min 2.5BAR 200L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve piece Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension mm 1000*950*1750 1250*1000*2000 1500*1250*2050 2050*1450*2050 2050*1450*2050
Dimension EX mm 1000*1200*1750 1250*1250*2000 1500*1500*2050 2050*1450*2050 2050*1450*2050
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material SUS 304 SUS 304 SUS 304 SUS 304 SUS304
Model ZLF-35N
ZLF-35NS
ZLF-35NH
ZLF-35NSH
ZLF-50N
ZLF-50NS
ZLF-50NH
ZLF-50NSH
ZLF-80N
ZLF-80NS
ZLF-80NH
ZLF-80NSH
ZLF-125N
ZLF-125NS
ZLF-125NH
ZLF-125NSH
ZLF-200N
ZLF-200NS
ZLF-200NH
ZLF-200NSH
Temp. range ℃ -45~ 250degree (setting the max temp according to the supplier heating or cooling source)
-40~135degree(The maximum temperature range can be operated by using glycol water formula.)
ZLF-  N The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled.
ZLF-  NS Besides ZLF- N function,add one set heater used to reduce high temp.
ZLF-  NH Besides ZLF- N function,add electrical heating function
ZLF-  NSH Besides ZLF- N function,add one set heater used to reduce high temp and electrical heating function
Heat exchanger area 3.5m2 5m2 8m2 12.5m2 20m2
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temp control selection Process temp control
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Process temp. feedback Raw material process feedback:PT100 or 4~20mA or communication given
Temp. feedback:PT100
temp feedback: normal PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 150L/min 2.5BAR 200L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve piece Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension mm 1000*950*1750 1250*1000*2000 1500*1250*2050 2050*1450*2050 2050*1450*2050
Dimension EX mm 1000*1200*1750 1250*1250*2000 1500*1500*2050 2050*1450*2050 2050*1450*2050
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material SUS 304 SUS 304 SUS 304 SUS 304 SUS304