Water Heater/Chiller Combo
First, points for attention in the selection of water heater/chiller combo:
1. Water heater/chiller combo is commonly used refrigeration and heating equipment in supporting reactors and reactors. There are different types of equipment for different working conditions. Commonly used models include SUNDI, SR, HR, etc., with different power and temperature ranges. The models are different.
2. When choosing a water heater/chiller combo, pay attention to the site conditions of the project and choose whether it is air-cooled or water-cooled. If it is water-cooled, it needs to have a water source that meets the conditions on site.
3. The temperature range of the water heater/chiller combo is relatively wide. The wider the temperature control condition, the more expensive the price is, but sometimes such a wide temperature range is not used. You can choose according to your actual temperature range. Heating, or cooling and heating at the same time, so that you can choose according to your exact working conditions.
4. Pay attention to the flow rate of the inlet and outlet of the reactor supporting the water heater/chiller combo. Do not choose large or small.
Second, the temperature control accuracy of water heater/chiller combo:
1. The water heater/chiller combo is a fully enclosed circulation pipeline. The interior of the equipment is a continuous circulation process. If you want to control the temperature accurately, the temperature control temperature should not be too high.
2. Different types of equipment have certain differences in the accuracy of temperature control. The PID control system adopted by the SUNDI series can operate independently and control the temperature accurately, generally around ±0.5°C.
Third, the isolation and explosion-proof customization of water heater/chiller combo
1. The water heater/chiller combo can provide customized styles of isolation and explosion-proof, which are different from conventional styles and have different prices.
2. Isolation and explosion-proof is to seal and isolate the electric control cabinet. The shell is made of fixed materials, has a certain explosion-proof level, and meets some standards. They are all passed the factory after debugging and testing.
Customized Solutions For Your Business
Cooling and Heating Systems (SUNDI series)
Temperature Control Range: -120°C to +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -40 ~ +200°C series | -10 ~ +200°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | -25 ~ +200°C one machine for two reactors | -40 ~ +200°C one machine for two reactors |
Cooling Capacity | up to 3kW | up to 15kW | up to 200kW | up to 200kW | up to 200kW | up to 25kW | up to 60kW | up to 25kW | up to 15kW | up to 80kW | up to 80kW | up to 80kW | up to 10*2kW | up to 10*2kW |
Cooling and Heating Systems (WTD series)
(Micro channel / tube reactors specialized)
Temperature Control Range: -70°C to +300°C
Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Cooling Capacity | up to 7.5kW | up to 5.5kW | up to 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | up to 25kW | up to 25kW | up to 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Cooling and Heating Circulators
Temperature Control Range: -45°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series |
Cooling Capacity | up to 15kW | up to 15kW |
Heating Circulators
Temperature Control Range: +50°C to +300°C
Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.
Temperature range | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) |
Heating Capacity | up to 38kW | up to 200kW | up to 95kW |
TCU Multi-reactors Temperature Control System
Temperature Control Range: -120°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C |
Heating Capacity | up to 80kW | up to 80kW | Custom | up to 300kW |