Search Search all

Water Cooling Chiller System

ClassificationIndustry News 212

Water Cooling Chiller System

 

The water cooling chiller system uses the shell-and-tube evaporator to exchange heat between water and the refrigerant. After the refrigerant system absorbs the heat load in the water and cools the water to produce cold water, the heat is brought to the shell-and-tube condenser by the action of the compressor. The refrigerant exchanges heat with the water, so that the water absorbs the heat and takes it out of the external cooling tower through the water pipe to dissipate it. At the beginning, the compressor sucks the low-temperature and low-pressure refrigerant gas after evaporation and refrigeration, and then compresses it into high-temperature and high-pressure gas and sends it to the condenser; After the high-pressure and high-temperature gas is cooled by the condenser, the gas is condensed into a normal-temperature and high-pressure liquid; when the normal-temperature and high-pressure liquid flows into the thermal expansion valve, it is throttled into low-temperature and low-pressure wet steam, which flows into the shell-and-tube evaporator to absorb the frozen water in the evaporator The heat lowers the water temperature; the evaporated refrigerant is sucked back into the compressor, and the cycle repeats.

The operation of the water cooling chiller system is inseparable from the water source. The better the quality of the water source, the less the range of equipment failures. Therefore, it is recommended to use high-quality water sources when using the water cooling chiller system, so as to reduce consumption and use costs, which is conducive to the long-term safe use of chillers by enterprises. The more stable the cooling performance of the water cooling chiller system is, the stricter the water source. Otherwise, various sudden failures will occur during the use of the equipment. So, what are the requirements of water cooling chiller system for water quality?

1. pH

Any water quality that is too alkaline or too acidic cannot meet the needs of industrial chillers, and even cause irreparable corrosive failures after long-term operation of industrial chillers. Therefore, when using the water cooling chiller system, high-quality water sources must be used in order to avoid a large number of equipment failures.

2. Hardness

Since the water cooling chiller system needs to use abundant water sources during operation, if the water quality is relatively hard, it will affect the operation of the chiller. Especially in the state of high-efficiency operation, it is easy to cause various scale problems inside the chiller. After the scale accumulates to a certain extent, it will affect the normal use of the chiller in the enterprise.

3. Water flow

If the water flow rate is too high or too low, it will restrict the operating efficiency of the equipment, and even lead to a decrease in the cooling performance of the chiller. Being able to continuously increase the water flow within a reasonable range can increase the safety of the operation of the chiller, and at the same time avoid problems such as affecting the operation of the chiller and causing irreparable losses due to the small water flow.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller