Search Search all

KRY Series Electric Vehicle Battery Pack Test Chiller

ClassificationIndustry News 178

KRY Series Electric Vehicle Battery Pack Test Chiller

 

At present, with the development of electric vehicle technology, the requirements for power batteries are getting higher and higher. In order to ensure the safety of the battery system, higher requirements are put forward for the thermal management of the battery system. Our company’s KRY series electric vehicle battery pack test Chiller is a liquid cooling temperature control system designed for new energy vehicle power battery systems.

The battery pack thermal management system adopts an integrated structure, and the equipment includes a refrigeration system, a heating system, and a water circulation system. Electric vehicle battery pack test Chiller is connected to the reserved liquid inlet and outlet of the battery pack water jacket through pipelines. The refrigeration system consists of compressors, heat exchangers, thermal expansion valves and other main components, dry filters, gas-liquid separators, etc. Auxiliary components, the heating system includes a built-in water tank heater and control elements, the water circulation system includes a magnetic circulating pump, a sealed circulating water tank, a stainless steel heat exchanger, an expansion tank and other devices.

Electric vehicle battery pack test Chiller uses the principle of vapor compression refrigeration. When cooling the battery pack, the electric heater does not start. The water pump pumps the antifreeze in the water tank into the water jacket of the battery pack. The liquid outlet of the battery pack is connected to the inlet of the plate heat exchanger, and the outlet of the plate heat exchanger is connected to the return port of the water tank to form a water circulation system. The battery pack comes out The antifreeze liquid and the refrigerant on the other side of the plate heat exchanger perform convective heat exchange to become cold antifreeze liquid, and then the cold antifreeze liquid flows into the water tank, and is exchanged with the battery pack through the pump to become hot antifreeze liquid. Reciprocating, to achieve the purpose of cooling the battery pack. When the heating principle heats up the battery environment, the compressor does not start, the electric heater in the water tank heats the antifreeze, and then pumps the hot antifreeze into the battery pack through the water pump to achieve the purpose of heating the battery pack.

Antifreeze is used as the medium for the Chiller medium of the electric vehicle battery pack test, and the circulating power is provided by the water pump. The expansion tank is designed for thermal expansion and contraction of the circulating medium. When the circulating medium expands at high temperature, the excess circulating medium enters the expansion tank. When the circulating medium contracts at low temperature, the circulating water tank is replenished. Electric vehicle battery pack test Chiller is used for the temperature of each temperature control point, including the temperature of the circulating water tank, the temperature of the return water of the battery pack, etc. Electric vehicle battery pack test Chiller uses PT100 temperature sensor to collect temperature data, and uses PLC controller as temperature controller to automatically control the temperature of each node in the whole system.

 

Custom Chillers                                                                                                                  

 

low temperature chiller

Low Temperature Chillers (Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW

 


recirculating chiller

Recirculating Chillers (Custom Designs)

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW

 


water chiller

Room Temperature Chillers / Small Chillers (Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW

 


Chillers for Automotive Battery Test (Custom Designs)

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.

 

Temperature range -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
Cooling Capacity2.8 ~ 38kW1.2 ~ 60kW1.8 ~ 60kW4 ~ 60kW

 

Temperature / Pressure / Flow can be independently controlled.

1&2: one machine for two groups control.

Temperature range -40 ~ +100℃ 1&20 ~ +100℃ 1&2
Cooling Capacity1.8kW*2 ~ 60kW*21.8kW*2 ~ 60kW*2

 

Temperature remains constant, pressure / flow can be independently controlled.

1&3: one machine for three groups control.

1&6: one machine for six groups control.

Temperature range -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
Cooling Capacity2.5 ~ 60kW4 ~ 60kW10 ~ 60kW10 ~ 60kW7 ~ 60kW11 ~ 60kW18 ~ 60kW

 


Semiconductor Chillers (TES series) (Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacity0.3 ~ 25kW0.25 ~ 25kW3 ~ 60kW

 


Semiconductor Chillers (LTS series) (Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


 

Chillers for Energy Storage(Custom Designs)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

Temperature range -45°C ~ +55°C
Cooling Capacity45kW

 


screw-chillers

 

Screw Chillers (Custom Designs)

Low temperature screw chillers and room temperature screw chillers

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacity107 ~ 1027kW (Single Compressor)299 ~ 2134kW (Dual Compressor)98 ~ 934kW (Single Compressor)272 ~ 1940kW (Dual Compressor)48 ~ 467kW (Single Compressor)51 ~ 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X

keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller