Selection Methods of Industrial Chiller
1. Comprehensive perspective consideration
First of all, choosing a high-quality merchant with a good reputation and qualified product quality can effectively improve the quality and efficiency of the chiller, and it is necessary to clarify the parameters of the chiller, and select a chiller with a good cooling effect according to your own needs. Comprehensively consider the industry reputation of chiller manufacturers, consider the cost performance in combination with their own needs, and at the same time pay attention to after-sales service, as an important factor in the purchase of chillers.
2. Selection basis – cooling capacity
The cooling capacity of the chiller has a direct impact on the normal operation of the production equipment. If the cooling capacity is small, it will not reflect the ideal cooling effect, but will reduce productivity loss and operation, resulting in stoppage of operation and shutdown. If the selection is too large, the waste cost will increase, and the greater the cooling capacity, the higher the price. Therefore, scientific and reasonable selection of cooling capacity is very important for the selection of chillers.
3. To optimize the type selection plan of the chiller
It is necessary to pay attention to the relationship between the temperature difference and the flow rate. Different plastic products have different cooling temperatures, and the water temperature difference is 3°C to 5°C. For the temperature difference, the smaller the sea salt temperature difference, the more ice water is needed. The flow takes away the same amount of heat, and vice versa, the flow of ice water is smaller. Ensure the minimum energy consumption scheme, comprehensive balance of electricity, heat and cold, especially the utilization of waste gas and waste heat. Reasonable control of noise pollution generated by chillers, scientific treatment of toxic substances in refrigerants, and continuous improvement of environmental protection quality. Improve the quality of cooling water to avoid dirt clogging pipes, thereby reducing cooling capacity or causing damage to heat exchange tubes. In view of the harsh environment and various flammable and explosive substances, it is necessary to make explosion-proof treatment according to the working environment of the chiller, and select the most suitable chiller scheme.
According to the specific refrigeration needs of the chiller, choose a chiller suitable for its own cooling, comprehensively consider environmental factors, human operation factors, architectural factors, and technical normative requirements, etc., can effectively improve the scientific and reasonable selection of chillers.
私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!
Temperature Control Range: -45°C ~ +250°C 7 Inch Color Touch Screen With 2pcs of LED Display Controller Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -25°C ~ +200°C 7 Inch Color Touch Screen With 2pcs of LED Display Controller Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -40°C ~ +200 °C Temperature Control Accuracy: ±0.5 °C 7-Inch,10 Inch color FTF Touch Screen Display Note: Both Air Coo...
Temperature Control Range: -10℃ ~ +150℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -25℃ ~ +200℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -25℃ ~ +300℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -45℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -45℃ ~ +300℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -60℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -60℃ ~ +300℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -70℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -80℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -90℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -100℃ ~ +100℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled A...
Temperature Control Range: -25°C ~ +200°C One Machine for Two Reactors Temperature Control Accuracy: ±0.5 °C 7-Inch,10 Inch color FTF Touch Screen...
Temperature Control Range: -40°C ~ +200°C One Machine for Two Reactors Temperature Control Accuracy: ±0.5 °C 7-Inch,10 Inch color FTF Touch Screen...
Temperature Control Range: -25°C ~ -5°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar)...
Temperature Control Range: -45°C ~ -10°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar...
Temperature Control Range: -18°C ~ +30°C Microcomputer Temperature Controller High Performance Circulating Pump Note: Both Air Cooled And Water C...
Temperature Control Range: +5°C ~ +35°C Microcomputer Temperature Controller High Performance Circulating Pump Note: Both Air Cooled And Water Co...
Temperature Control Range: -60°C ~ -10°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar...
Temperature Control Range: -80°C ~ -30°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar...
Temperature Control Range: -110°C ~ -50°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipola...
Temperature Control Range: -150°C ~ -110°C Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar) Piston Compressor, Sem...
Temperature Control Range: -25°C ~ +30°C (optional: -120°C ~ +35°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -45°C ~ +30°C (optional: -120°C ~ +35°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -60°C ~ -20°C (optional: -120°C ~ +30°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -80°C ~ -20°C (optional: -120°C ~ +30°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -120°C ~ -70°C (optional: -120°C ~ +30°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, ...
The temperature range of the equipment is -110 ℃ ~ -40 ℃, using environmentally friendly refrigerant, the cooling speed is fast. The products use b...
It is widely used in high and low temperature testing of semiconductor equipment. Cold and heat sources for high temperature and low temperature co...
Temperature Control Range: -115°C ~ +225°C Siemens PLC Controller Danfoss / Emerson Fittings Application: Laboratory, Research Institute, ...
自動車用テスト・チラー
温度制御範囲:-40℃~+100
商品を見る
半導体テストチラー
温度制御範囲:-85℃~+250
商品を見る
工業用冷蔵庫
温度制御範囲:-150℃~-10
商品を見る
著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com
または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。
WhatsAPP WeChat