The high and low temperature refrigeration heating circulator can provide high and low temperature circulating liquid for the equipment that needs cooling or heating, such as the reaction kettle, etc., and provide heat source or cold source for the reaction vessel through external circulation, so as to achieve the required conditions for the reaction, and the temperature control accuracy is high.

So about the issues that need to be paid attention to in the operation process, the use method and installation precautions of the high and low temperature refrigeration and heating circulator, I will explain to you!

1. Before use, it is necessary to check whether the main power supply has been connected, whether there is a reverse phase or phase loss of the power supply, and whether the power supply reverse phase or phase loss protection device is installed.

2. Before installation, it is also necessary to check whether the oil pump of the high and low temperature refrigeration and heating circulator is reversed to prevent damage to the motor.

3. After injecting the heat transfer oil, let the high temperature oil pump run for a period of time, wait until the pressure of the high and low temperature refrigeration and heating circulator is normal and the pointer of the system pressure gauge does not shake left and right, and then heat up and work.

4. Check the liquid level. When the heat transfer oil is sufficient, the temperature can be started. When the loss of heat transfer oil is insufficient, it should be replenished in time to avoid mechanical dry burning damage.

5. Use the conversion of heat transfer oil to heat the material to be heated. The inferior heat transfer oil has a short service life and is prone to scaling. In the high temperature state, impurities will decompose, the temperature cannot rise, water vapor will be generated, and fuel injection will occur, which is also dangerous.

6. In the process of use and maintenance, the probability of failure is still relatively low. Some of these erroneous operations will result in the life of the high and low temperature refrigeration and heating circulators being affected.

7. The liquid refrigerant in the evaporator continuously absorbs the heat in the water and starts to evaporate. After the compression of the compressor and the throttling of the expansion valve, it becomes a low temperature and low pressure refrigerant and enters the evaporator to continue to circulate. If the use time is too long, the refrigerant will volatilize, which will affect the cooling effect.

私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!

 


低温冷水機

ウォーターチラー

温度制御範囲:-150℃~+50

 

 


冷暖房システム

ダイナミック温度制御システム

温度制御範囲:-120°C~+350°C

 

 

 


バッテリー冷却システム

自動車用テスト・チラー

温度制御範囲:-40℃~+100

 

 

 


半導体テストチラー

半導体テストチラー

温度制御範囲:-85℃~+250

 

 

 


工業用冷凍庫

工業用冷蔵庫

温度制御範囲:-150℃~-10