Daily Maintenance of Industrial Water Chillers

 

Although the industrial chiller is equipped with multiple protection devices, these are all to prevent the failure of the unit from directly damaging the unit. If the enterprise wants to ensure the high cooling efficiency and long service life of the chiller, it must remember to do regular maintenance.

So, how to carry out normal safety maintenance and testing of industrial chillers?

1. Check the stability of voltage and current

When the air-cooled chiller is working normally, the voltage is 380V, and the current is normal within the range of 11A-15A;

2. Regularly check the compressor

The compressor is the “heart” of the chiller, and its quality directly affects the stability of the chiller when it is used. The necessary acceptance test of the chiller should be carried out in accordance with the principle of first air tightness test, then vacuum test, first sub-item test, and then complete machine test.

3. Regular cleaning

In addition to checking the technical performance of the chiller, attention should also be paid to protecting the clean appearance of the unit and the cleanliness of the work site. When the chiller runs for 6 months, it is necessary to clean the entire system, such as pipes, filters, condensers, fans, etc., especially the fans and condensers. Like our commonly used fans, dust is full of dust and affects heat dissipation, so the cooling efficiency will be reduced. directly lower.

4. Regularly check the instrument: the temperature control meter is out of control, replace the temperature control meter, high pressure failure, poor heat dissipation, dirty radiator, poor ventilation after cleaning the radiator, improve ventilation conditions, the cooling fan does not work, check whether the fan motor is burnt out, repair or replace it The high-voltage engine of the motor motor is damaged, replace the high-voltage engine.

5. Regularly check whether the refrigerant is reduced

Judging by the high and low pressure gauge values ​​on the front of the chiller. When the chiller is in normal operation, the high pressure is 11-17kg and the low pressure is 3-5kg is the normal range. In the shutdown state, both high pressure and low pressure are around 0.6kg.

6. Regularly check the cooling water pressure and water temperature.

The cooling water pressure and water temperature determine the heat dissipation of the chiller, and the switch should be regularly checked every day to see if it is within the normal range. It is best to install a water pressure gauge and a temperature gauge in a conditional working environment.

7. Regularly check whether the internal parts of the electric control box are loose, burnt, scorched and other abnormal conditions. If you find it, you should immediately notify the professionals of the chiller manufacturer to come over for maintenance.

8. The water-cooled chiller should also regularly check whether the cooling tower is operating normally.

私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!

 


低温冷水機

ウォーターチラー

温度制御範囲:-150℃~+50

 


冷暖房システム

ダイナミック温度制御システム

温度制御範囲:-120°C~+350°C

 

 


バッテリー冷却システム

自動車用テスト・チラー

温度制御範囲:-40℃~+100

 

 


半導体テストチラー

半導体テストチラー

温度制御範囲:-85℃~+250

 

 


工業用冷凍庫

工業用冷蔵庫

温度制御範囲:-150℃~-10

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
無料見積もりプラン

ロード...

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー