Buscar en Buscar todos

Heating and Cooling Chiller

ClasificaciónNoticias del sector 226

Heating and Cooling Chiller

 

The heating and cooling chiller adopts a fully closed cycle. It will not generate oil mist at high temperature and will not absorb water at low temperature. There is an expansion tank in the system. During the cooling and heating process, the heat transfer medium expands with heat and contracts with cold. It has a thermodynamic temperature control system. A series of functions meet high requirements, technology guarantees high precision of temperature control and good repeatability of results, short heating and cooling time, wide temperature range, simple navigation menu, important parameters at a glance, and real-time temperature changes are displayed in the form of graphs, ensuring Stable circulation and flow prevent damage to glass reactors caused by soft starts.

The main function of heating and cooling chiller is used for heating and cooling of glass reactors, metal reactors, and bioreactors. It is especially suitable for linear control of the temperature of materials in the reactor when there is a need for heat and exothermic process control during the reaction process. You can choose In the program control mode, the temperature difference between the heat transfer medium and the material can also be set.

There are two main control principles of heating and cooling chiller:

1. The method of changing the control setting value can respond to the system lag in the process as soon as possible and obtain a smaller system overshoot. The control consists of two sets of PID control loops, which are called the main loop and the slave loop, and the control output of the master loop is used as the set value of the slave loop. The system adopts feed-forward PV, the output of the PID operation result of the main control loop is compounded with the feed-forward PV signal as the set value of the slave control loop, and through this gradient control of temperature changes, the temperature control accuracy of the system is guaranteed.

2. The hysteresis estimator generates a dynamic signal instead of the process variable as the feedback signal. Generate a signal to the controller, so that the controller does not have a large delay in predicting the control effect, so that the controller can always generate an appropriate control signal. That is, this dynamic signal keeps the feedback loop working properly even in the presence of large hysteresis. However, if the general PID is used to control the process with significant time lag, the controller output will keep increasing during the lag time due to the lack of proper feedback signal, which will lead to a large overshoot of the system response and even make the system out of control.

 

Soluciones personalizadas para su empresa


Sistemas de refrigeración y calefacción (serie SUNDI)

Rango de control de temperatura: -120°C a +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperatura Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C una máquina para dos reactores -40 ~ +200°C una máquina para dos reactores
Capacidad de refrigeraciónhasta 3 kWhasta 15 kWhasta 200 kWhasta 200 kWhasta 200 kWhasta 25 kWhasta 60 kWhasta 25 kWhasta 15 kWhasta 80 kWhasta 80 kWhasta 80 kWhasta 10*2 kWhasta 10*2 kW

 


Sistemas de refrigeración y calefacción (serie WTD)

(Microcanales / reactores tubulares especializados)

Rango de control de temperatura: de -70°C a +300°C

Diseño especializado para microcanal (pequeña capacidad de retención de líquido, gran capacidad de intercambio de calor, sistema de circulación de alta caída de presión)

 

Temperatura -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Capacidad de refrigeraciónup to 7.5kWup to 5.5kWhasta 50 kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperatura Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Capacidad de refrigeraciónhasta 25 kWhasta 25 kWhasta 60 kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperatura Serie -20°C ~ +80°C Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Control de caudal7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Circuladores de refrigeración y calefacción

Rango de control de temperatura: -45°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperatura Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Capacidad de refrigeraciónhasta 15 kWhasta 15 kW

 


Termostatos de circulación

Rango de control de temperatura: +50°C a +300°C

Nota: La serie UC puede controlar la temperatura del medio de transferencia de calor. La serie UST no solo puede controlar la temperatura del medio de transferencia de calor, sino también la temperatura del material de reacción.

Temperatura +50°C ~ +200°C  (UC series) +50°C ~ +300°C (serie UC) +50°C ~ +300°C (serie UST)
Capacidad de calefacciónhasta 38 kWhasta 200 kWhasta 95 kW

 


TCU Sistema de control de temperatura multirreactores

Rango de control de temperatura: -120°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperatura Serie -45°C ~ +250°C Serie -120°C ~ +250°CSistema de control de temperatura personalizadoRT+10°C ~ +135°C
Capacidad de calefacciónhasta 80 kWhasta 80 kWA medidaup to 300kW

 

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Obtener presupuesto gratuito

cargando...

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua