Heater and Cooler
Heater and cooler is also called cooling and heating integrated machine, which mainly provides high and low temperature circulating fluid for equipment that needs heating or cooling, such as glass reactors and rotary evaporators. Heated by heat conduction oil, circulated to the jacket layer of the reaction kettle through the circulation pump, and a periodic cycle is carried out in the pipeline and the jacket. With unique heating design, the temperature can be automatically controlled to quickly reach the temperature required by the product process, and intelligent PID is adopted. Control technology, can heat constant temperature or cool down, wide temperature control range, accurate, uniform and stable temperature, fast heat conduction speed, fast temperature rise and fall speed, temperature self-control, quickly meet the temperature requirements of various products.
The compressor is one of the main components of the heater and cooler. If it is not maintained for a long time, its performance will affect the cooling effect. If it fails, its refrigeration system cannot be operated. The compressor in this unit is high temperature and low pressure refrigerant is compressed into high temperature and high pressure, so that the refrigeration system of the unit can achieve the required temperature range. As a main accessory, the compressor’s performance is related to the operation of the entire device, so the compressor needs to be maintained after long-term use.
The compressor will protect itself when it is overloaded or overheated, and this protection device has two types: built-in type and external type, and only the external type is mentioned here. If the compressor cannot start automatically within 3 minutes after the protection occurs, it means that the protector has been activated. After the protection occurs, due to the high temperature of the compressor body and slow heat dissipation, the reset time of the protector is relatively long, usually 3 to 15 minutes, and the longest can reach 30 minutes. If it still fails to start after 30 minutes, the overload and overheat protector may be damaged.
When the capacitor capacity of the compressor decays to 58% of its original value, when the outdoor ambient temperature is lower than minus 5°C, when the power supply voltage is lower than 16%, and when the system pressure is not yet balanced. These factors will cause difficulty in starting the compressor. In fact, the shaft holding and the stuck cylinder have the same meaning. It is a compressor failure or the compressor has been damaged. The main reason for the stuck cylinder is that the system is dirty or lacks oil. Generally, the cylinder body and the valve plate will be damaged to varying degrees. In principle, it cannot be repaired or cannot be repaired, and the compressor needs to be replaced with a new one. However, there are many experiences in dealing with cylinder jams, and some compressors with less serious cylinder jams can be saved by knocking, increasing capacitors, etc.
Soluciones personalizadas para su empresa
Sistemas de refrigeración y calefacción (serie SUNDI)
Rango de control de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -40 ~ +200°C | Serie -10 ~ +200°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | -25 ~ +200°C una máquina para dos reactores | -40 ~ +200°C una máquina para dos reactores |
Capacidad de refrigeración | hasta 3 kW | hasta 15 kW | hasta 200 kW | hasta 200 kW | hasta 200 kW | hasta 25 kW | hasta 60 kW | hasta 25 kW | hasta 15 kW | hasta 80 kW | hasta 80 kW | hasta 80 kW | hasta 10*2 kW | hasta 10*2 kW |
Sistemas de refrigeración y calefacción (serie WTD)
(Microcanales / reactores tubulares especializados)
Rango de control de temperatura: de -70°C a +300°C
Diseño especializado para microcanal (pequeña capacidad de retención de líquido, gran capacidad de intercambio de calor, sistema de circulación de alta caída de presión)
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidad de refrigeración | up to 7.5kW | up to 5.5kW | hasta 50 kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperatura | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Capacidad de refrigeración | hasta 25 kW | hasta 25 kW | hasta 60 kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperatura | Serie -20°C ~ +80°C | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Control de caudal | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de refrigeración y calefacción
Rango de control de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C |
Capacidad de refrigeración | hasta 15 kW | hasta 15 kW |
Termostatos de circulación
Rango de control de temperatura: +50°C a +300°C
Nota: La serie UC puede controlar la temperatura del medio de transferencia de calor. La serie UST no solo puede controlar la temperatura del medio de transferencia de calor, sino también la temperatura del material de reacción.
Temperatura | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (serie UC) | +50°C ~ +300°C (serie UST) |
Capacidad de calefacción | hasta 38 kW | hasta 200 kW | hasta 95 kW |
TCU Sistema de control de temperatura multirreactores
Rango de control de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C |
Capacidad de calefacción | hasta 80 kW | hasta 80 kW | A medida | up to 300kW |