5 Ton Water Chiller – Industrial Chiller Supplier
The relevant parts of the 5 ton water chiller will cause certain problems during use. Therefore, reasonable and scientific maintenance and repair can effectively avoid the occurrence of failures.
First, inspection and maintenance of 5 ton water chiller
The compressor of the chiller will make noise when it is working. This may be a problem with the expansion valve. Pay more attention to the expansion valve at ordinary times. In addition, the pipeline and condenser should be cleaned regularly to ensure smooth circulation. If the suction pressure of your 5 ton water chiller is too high, pay attention to the amount of refrigerant used, excess or reduction will cause the suction pressure to rise, and improper adjustment of the expansion valve will also cause changes in the suction of the chiller.
Second, the maintenance method of the condenser
1. Detection
Condenser is a key part in 5 ton water chiller, therefore, in the production process, various failures often occur. Pay close attention to the pressure of the condenser, do not add too much refrigerant, and do not have air and non-condensable gases, otherwise the pressure of the condenser will increase, which will affect the normal operation of the condenser.
2. Environment
As long as the condenser of the 5 ton water chiller is in normal working condition, its working efficiency will reach a very high level. Since the main function of the condenser is cooling, it will definitely cause different degrees of pollution to the nearby environment in the case of a bad working environment. Only a good heat dissipation effect can ensure the normal operation of the condenser of the industrial chiller.
Therefore, in daily maintenance, it is necessary to ensure that the temperature of the condenser is volatilized in the shortest time, so as to ensure the cooling capacity of the equipment and ensure the safety of the operation of the equipment.
3. Clean
When using the 5 ton water chiller, all parts must be cleaned carefully to ensure its normal operation. Especially the fins, because there are gaps between the fins, a large amount of dust will seep into the fins, resulting in poor heat dissipation and seriously affecting the work of the condenser. It is necessary to ensure that the condenser is checked regularly after the 6-month cycle of the industrial chiller.
If it is used for a long time, thick dirt will form on the heat transfer surface of the condenser, and it will adhere to the surface of the radiator. As time goes by, it will affect the heat dissipation effect of the condenser, and regular descaling and maintenance must be carried out.
Soluciones personalizadas para su empresa
Refrigeradores de baja temperatura (por agua o por aire)
Tecnología de refrigeración en cascada a temperatura ultrabaja.
Cada segmento de temperatura cuenta con más de una docena de modelos de productos entre los que elegir.
Temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C |
Capacidad de refrigeración | 3 ~ 103 Ton | 1,5 ~ 103 toneladas | 1,5 ~ 103 toneladas | 1,1 ~ 77 toneladas | 0,5 ~ 52 toneladas | 0,7 ~ 3,2 Ton |
Enfriadoras de recirculación (Refrigerado por agua o por aire)
Tubería de circulación cerrada, etilenglicol mezclado con agua para refrigeración.
Temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Capacidad de refrigeración | 0,2 ~ 11 toneladas | 0,1 ~ 3,5 toneladas | 0,1 ~ 2,1 Ton | 0,05 ~ 2,1 Ton | 0,08 ~ 2,5 toneladas |
Refrigeradores de temperatura ambiente / Refrigeradores pequeños
Sistema de control de temperatura de refrigeración de alta precisión.
Temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C |
Capacidad de refrigeración | 0,09 ~ 0,26 Ton | 0,5 ~ 15 toneladas |
Equipos frigoríficos de refrigeración directa
Es adecuado para lugares con poca superficie de intercambio de calor y gran intercambio de calor.
Temperatura | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Potencia del compresor | hasta 8CV | hasta 8CV*2 | hasta 45 CV*3 |
Enfriadoras de temperatura ultrabaja de refrigeración directa
El enfriador directo de temperatura ultrabaja adopta la tecnología de subenfriamiento secundario, y la velocidad de enfriamiento es rápida. El refrigerante del sistema de refrigeración sale directamente y se evapora en el elemento de control de destino (intercambiador de calor) para enfriar.
Temperatura | -150°C ~ -110°C |
Capacidad de refrigeración | hasta 11 kW |