The relevant parts of the 5 ton water chiller will cause certain problems during use. Therefore, reasonable and scientific maintenance and repair can effectively avoid the occurrence of failures.

First, inspection and maintenance of 5 ton water chiller

The compressor of the chiller will make noise when it is working. This may be a problem with the expansion valve. Pay more attention to the expansion valve at ordinary times. In addition, the pipeline and condenser should be cleaned regularly to ensure smooth circulation. If the suction pressure of your 5 ton water chiller is too high, pay attention to the amount of refrigerant used, excess or reduction will cause the suction pressure to rise, and improper adjustment of the expansion valve will also cause changes in the suction of the chiller.

Second, the maintenance method of the condenser

1. Detection

Condenser is a key part in 5 ton water chiller, therefore, in the production process, various failures often occur. Pay close attention to the pressure of the condenser, do not add too much refrigerant, and do not have air and non-condensable gases, otherwise the pressure of the condenser will increase, which will affect the normal operation of the condenser.

2. Environment

As long as the condenser of the 5 ton water chiller is in normal working condition, its working efficiency will reach a very high level. Since the main function of the condenser is cooling, it will definitely cause different degrees of pollution to the nearby environment in the case of a bad working environment. Only a good heat dissipation effect can ensure the normal operation of the condenser of the industrial chiller.

Therefore, in daily maintenance, it is necessary to ensure that the temperature of the condenser is volatilized in the shortest time, so as to ensure the cooling capacity of the equipment and ensure the safety of the operation of the equipment.

3. Clean

When using the 5 ton water chiller, all parts must be cleaned carefully to ensure its normal operation. Especially the fins, because there are gaps between the fins, a large amount of dust will seep into the fins, resulting in poor heat dissipation and seriously affecting the work of the condenser. It is necessary to ensure that the condenser is checked regularly after the 6-month cycle of the industrial chiller.

If it is used for a long time, thick dirt will form on the heat transfer surface of the condenser, and it will adhere to the surface of the radiator. As time goes by, it will affect the heat dissipation effect of the condenser, and regular descaling and maintenance must be carried out.

 

비즈니스를 위한 맞춤형 솔루션


저온 냉각기

 

저온 냉각기(수냉식 또는 공냉식)

초저온 캐스케이드 냉장 기술.

각 온도 세그먼트에는 선택할 수 있는 12가지 이상의 제품 모델이 있습니다.

온도 범위 -25°C ~ -5°C 시리즈 -45°C ~ -10°C 시리즈 -60°C ~ -10°C 시리즈 -80°C ~ -30°C 시리즈 -110°C ~ -50°C 시리즈 -150°C ~ -110°C 시리즈
냉각 용량3 ~ 103톤1.5 ~ 103톤1.5 ~ 103톤1.1 ~ 77톤0.5 ~ 52톤0.7 ~ 3.2톤

 


재순환 냉각기

 

재순환 냉각기(수냉식 또는 공냉식)

폐쇄 순환 파이프 라인, 냉장용 물과 혼합된 에틸렌 글리콜.

온도 범위 -25°C ~ +30°C 시리즈 -45°C ~ +30°C 시리즈 -60°C ~ -20°C 시리즈 -80°C ~ -20°C 시리즈 -120°C ~ -70°C 시리즈
냉각 용량0.2 ~ 11톤0.1 ~ 3.5톤0.1 ~ 2.1톤0.05 ~ 2.1톤0.08 ~ 2.5톤

 


물 냉각기

 

실온 냉각기/소형 냉각기

고정밀 냉장 온도 제어 시스템.

온도 범위 -18°C ~ +30°C +5°C ~ +35°C 시리즈
냉각 용량0.09 ~ 0.26톤0.5 ~ 15톤

 


직접 냉각 기계

 

직접 냉각식 냉동 장비

열 교환 면적이 작고 열 교환이 큰 장소에 적합합니다.

온도 범위 -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
압축기 전력최대 8HP최대 8HP*2최대 45HP*3

 


 

직접 냉각식 초저온 냉각기

초저온 직접 냉각식 칠러는 2차 과냉각 기술을 채택하여 냉각 속도가 빠릅니다. 냉동 시스템의 냉매가 직접 출력되어 대상 제어 요소(열교환기)로 증발하여 냉각됩니다.

온도 범위 -150°C ~ -110°C
냉각 용량최대 11kW