Suche Alle suchen

Low Temperature Industrial Chiller Maintenance

KlassifizierungIndustrie-Nachrichten 167

Low Temperature Industrial Chiller Maintenance

 

1. During the initial operation of the industrial low-temperature chiller, the oil level, oil return condition and oil cleanliness of the compressor should be observed frequently. If the oil is dirty or the oil level drops, it should be replaced or added in time to avoid poor lubrication and affect the operation of the equipment. .

2. For the air-cooled chiller: the air-cooler should be cleaned frequently to maintain a good heat exchange state, and the condenser should be checked frequently for scaling problems, and the scale should be removed in time.

3. For water-cooled chillers: Always check the turbidity of the cooling water. If the cooling water is too dirty, it must be replaced, whether the water pump is working properly, whether the valve switch is effective, and whether the cooling water tower and fan are normal.

4. For the evaporator of the air-cooled chiller: it is necessary to check the defrosting situation frequently, whether the defrosting is timely and effective, and whether it will affect the cooling effect.

5. Always observe the running state of the compressor and check its exhaust temperature. When running in seasons, pay special attention to the operating status of the system, and adjust the liquid supply volume and condensing temperature of the system in time.

6. Listen carefully to the running sound of the compressor, cooling tower, water pump or condenser fan, find and deal with it in time, and check the vibration of the compressor, exhaust pipe and water pump.

7. After 30 days of operation, the refrigerating oil and drying filter should be replaced once, and after half a year of operation (depending on the actual situation). For systems with higher cleanliness, the refrigeration oil and filter drier should also be replaced after six months of operation.

Wir sind ein professioneller Hersteller von Temperaturkontrollgeräten und unterstützen kundenspezifische Dienstleistungen, bitte uns konsultieren für Details!

 


Niedertemperatur-Wasserkühler

Kaltwassersätze

Temperaturregelbereich: -150°C bis +50°C

 

 


Kühl- und Heizsystem

Dynamische Temperaturkontrollsysteme

Temperaturregelbereich: -120°C bis +350°C

 

 

 


Batteriekühlsystem

Test-Kühlgeräte für Kraftfahrzeuge

Temperaturregelbereich: -40°C bis +100°C

 

 

 


Halbleiter-Testkühler

Halbleiter-Test-Kühlgeräte

Temperaturregelbereich: -85°C bis +250°C

 

 

 


industrieller Gefrierschrank

Industrielle Kühlschränke

Temperaturregelbereich: -150°C bis -10°C

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz