Low Temperature Industrial Chiller Maintenance

ClassificationNouvelles de l'industrie 169

Low Temperature Industrial Chiller Maintenance

 

1. During the initial operation of the industrial low-temperature chiller, the oil level, oil return condition and oil cleanliness of the compressor should be observed frequently. If the oil is dirty or the oil level drops, it should be replaced or added in time to avoid poor lubrication and affect the operation of the equipment. .

2. For the air-cooled chiller: the air-cooler should be cleaned frequently to maintain a good heat exchange state, and the condenser should be checked frequently for scaling problems, and the scale should be removed in time.

3. For water-cooled chillers: Always check the turbidity of the cooling water. If the cooling water is too dirty, it must be replaced, whether the water pump is working properly, whether the valve switch is effective, and whether the cooling water tower and fan are normal.

4. For the evaporator of the air-cooled chiller: it is necessary to check the defrosting situation frequently, whether the defrosting is timely and effective, and whether it will affect the cooling effect.

5. Always observe the running state of the compressor and check its exhaust temperature. When running in seasons, pay special attention to the operating status of the system, and adjust the liquid supply volume and condensing temperature of the system in time.

6. Listen carefully to the running sound of the compressor, cooling tower, water pump or condenser fan, find and deal with it in time, and check the vibration of the compressor, exhaust pipe and water pump.

7. After 30 days of operation, the refrigerating oil and drying filter should be replaced once, and after half a year of operation (depending on the actual situation). For systems with higher cleanliness, the refrigeration oil and filter drier should also be replaced after six months of operation.

Nous sommes un fabricant professionnel d'équipements de contrôle de la température et nous offrons des services personnalisés. nous consulter pour plus de détails !

 


refroidisseur d'eau à basse température

Refroidisseurs d'eau

Plage de contrôle de la température : -150°C à +50°C

 

 


système de refroidissement et de chauffage

Systèmes de contrôle dynamique de la température

Plage de contrôle de la température : -120°C à +350°C

 

 

 


système de refroidissement de la batterie

Refroidisseurs pour essais automobiles

Plage de contrôle de la température : -40°C à +100°C

 

 

 


refroidisseur pour tests de semi-conducteurs

Refroidisseurs pour essais de semi-conducteurs

Plage de contrôle de la température : -85°C à +250°C

 

 

 


congélateur industriel

Réfrigérateurs industriels

Plage de contrôle de la température : -150°C à -10°C

Les informations sur les droits d'auteur appartiennent à lneya-online.com, veuillez contacter l'e-mail pour plus de détails : lilia@lneya.com

Ou scannez le code QR WhatsApp ou WeChat ci-dessous pour nous contacter. 

WhatsAPP WeChat

scanner

Précédent : Suivant :
Obtenir un devis gratuit Plan

chargement...

购物车

X

我的足迹

X
mots-clés:La joie en bouteille refroidisseur d'eau