First, the operation process introduction of heater and cooler 2 in 1:

In the cooling and heating temperature control of the reaction kettle or reactor, the temperature control of the heater and cooler 2 in 1 reaches the expected temperature range. The whole process will produce a certain chemical reaction, generate heat, and the reaction process is easily affected by the outside, so the placement environment should also be Notice.

When the heater and cooler 2 in 1 is equipped with a reactor or reactor for polymerization, a series of exothermic and endothermic reactions will occur. During the chemical reaction, it is recommended that the surrounding operators should not be too close to avoid some troubles. During the reaction process, if the heat is not removed in time, the reaction pressure will be affected. If the pressure is too high, the entire reaction will be in some danger.

Second, the selection considerations for heater and cooler 2 in 1:

The heater and cooler 2 in 1 can be equipped with reactors or reactors of different sizes for refrigeration, heating and temperature control. Due to the different heat capacities of reactors or reactors of different sizes, their heat absorption or heat release capabilities are also different.

1. Heater and cooler 2 in 1 is used in various industries. When choosing, you need to choose according to the size, weight, type and volume of the jacket or coil of the reactor or reactor. The heat ratio and viscosity of the materials in the reactor are closely related.

2. The temperature required by the heater and cooler 2 in 1 is also related to the temperature requirements of the equipment model, so choose the appropriate model of Guanya high and low temperature all-in-one machine to make the experiment reach the required temperature range.

3. When selecting heater and cooler 2 in 1, it is necessary to calculate the size of the jacket or coil to estimate the time required for temperature control. Users can customize whether they need explosion-proof or isolation according to their needs.

4. Heater and cooler 2 in 1 is divided into air cooling and water cooling. According to different cooling methods, users can choose according to their actual environmental requirements. Water-cooled devices need to be in an environment with ample water. If the water source environment is not suitable, air-cooled equipment can be used.

5. Heater and cooler 2 in 1 have different temperatures and media, and are divided into oil cooling equipment and water cooling equipment. Different temperatures, different media, room temperature, heat transfer oils and refrigerants.

The heater and cooler 2 in 1 can control one or more reaction kettles at the same time. It is a large system device with integrated temperature control. The fully enclosed circulation pipeline can automatically heat or cool according to the process requirements.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


Kühl- und Heizsysteme (Serie SUNDI)

Temperaturregelbereich: -120°C bis +350°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Automobilindustrie, Halbleiter- und Elektrotests, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C eine Maschine für zwei Reaktoren -40 ~ +200°C eine Maschine für zwei Reaktoren
Kühlleistungbis zu 3kWbis zu 15kWbis zu 200kWbis zu 200kWbis zu 200kWbis zu 25kWbis zu 60kWbis zu 25kWbis zu 15kWbis zu 80kWbis zu 80kWbis zu 80kWbis zu 10*2kWbis zu 10*2kW

 


Kühl- und Heizsysteme (WTD-Serie)

(Mikrokanal / Röhrenreaktoren spezialisiert)

Temperaturregelbereich: -70°C bis +300°C

Spezielles Design für Mikrokanäle (geringe Flüssigkeitsspeicherkapazität, starke Wärmeaustauschkapazität, Zirkulationssystem mit hohem Druckabfall)

 

Temperaturbereich -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Kühlleistungbis zu 7,5 kWbis zu 5,5 kWbis zu 50kW

 


Kühl- und Heizsysteme (TES-Serie)

Temperaturregelbereich: -85°C ~ +250°C

Temperaturregelungsgenauigkeit: ± 0,3°C

 

 

Temperaturbereich Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Kühlleistungbis zu 25kWbis zu 25kWbis zu 60kW

 


Kühl- und Heizmaschinen (LTS-Serie)

Temperaturregelbereich: -80°C bis +80°C

Es wird häufig in der Halbleiterindustrie eingesetzt, um die Temperatur der Reaktionskammer, der Heizplatte und des nicht brennbaren Wärmeträgers zu regeln.

 

 

Temperaturbereich -20°C ~ +80°C Reihe Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Durchflusskontrolle7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Umwälzpumpen für Kühlung und Heizung

Temperaturregelbereich: -45°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Kühlleistungbis zu 15kWbis zu 15kW

 


Heizungsumwälzpumpen

Temperaturregelbereich: +50°C bis +300°C

Hinweis: Die UC-Serie kann die Temperatur des Wärmeträgermediums regeln. Die UST-Serie kann nicht nur die Temperatur des Wärmeträgermediums, sondern auch die Temperatur des Reaktionsmaterials regeln.

Temperaturbereich +50°C ~ +200°C (UC-Serie) +50°C ~ +300°C (UC-Serie) +50°C ~ +300°C (UST-Serie)
Heizleistungbis zu 38kWbis zu 200kWbis zu 95 kW

 


TCU Multireaktoren Temperaturkontrollsystem

Temperaturregelbereich: -120°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -45°C ~ +250°C -120°C ~ +250°C ReiheKundenspezifisches TemperaturkontrollsystemRT+10°C ~ +135°C
Heizleistungbis zu 80kWbis zu 80kWBenutzerdefiniertbis zu 300kW

 

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz