Chiller 11 kw – Refrigerated Chillers
In the daily operation process, even when the 11 kw chiller is working normally, occasionally the cooling effect is not very good, and the cooling temperature cannot reach our expected effect. If the cooling effect of the 11 kw chiller is not good, it will affect the normal operation of the equipment, thereby affecting the progress of production. Therefore, we must deal with it quickly. So what to do if the cooling effect of the 11 kw chiller is not very good?
11 kw chiller cooling effect is not so good reason and solution:
1. There is a problem with the thermostat
There is a problem with the thermostat of the 11 kw chiller, and the temperature control cannot be completed. You need to contact the after-sales service technicians of the chiller manufacturer to replace the thermostat.
2. Insufficient refrigerant or leakage
If the chiller has insufficient refrigerant or the refrigeration system leaks refrigerant, it is recommended to contact after-sales service technicians to find the leak, repair it and refill the refrigerant.
3. The external working temperature is too high
When the room is closed and airless or in a natural environment above 40°C, the 11 kw chiller cannot transfer heat to the outside, resulting in no cooling.
4. Long-term maintenance without cleaning
After the chiller has been in use for a period of time, if it is not cleaned and maintained for a long time, it is very easy to cause a lot of dust accumulation in the internal parts of the 11 kw chiller, and the pipeline is also very easy to generate dirt, breed bacteria, and the heat cannot be discharged, resulting in reduced cooling effect . Therefore, we need to regularly clean and maintain the 11 kw chiller.
The content introduced above is the reason and solution for the poor cooling effect of the 11 kw chiller. There are many reasons why the cooling effect of the chiller is not very good. The most common reason is that the cooling effect has deteriorated due to the lack of timely maintenance of the chiller. Therefore, we must pay attention to the maintenance of the chiller.
Customized Solutions For Your Business
Low Temperature Chillers (Custom Designs)
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW | up to 11kW |
Recirculating Chillers (Custom Designs)
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers (Custom Designs)
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments (Custom Designs)
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Chillers for Automotive Battery Test (Custom Designs)
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Temperature range | -25°C ~ +100°C | -40°C ~ +100°C | 0°C ~ +100°C | -40°C ~ +135°C |
Cooling Capacity | up to 38kW | up to 60kW | up to 60kW | up to 60kW |
Temperature / Pressure / Flow can be independently controlled.
1&2: one machine for two groups control.
Temperature range | -40 ~ +100℃ 1&2 | 0 ~ +100℃ 1&2 |
Cooling Capacity | up to 60kW*2 | up to 60kW*2 |
Temperature remains constant, pressure / flow can be independently controlled.
1&3: one machine for three groups control.
1&6: one machine for six groups control.
Temperature range | -40 ~ +100℃ 1&2 | -40 ~ +100℃ 1&3 | -40 ~ +100℃ 1&6 | -20 ~ +100℃ 1&6 | 0 ~ +100℃ 1&2 | 0 ~ +100℃ 1&3 | 0 ~ +100℃ 1&6 |
Cooling Capacity | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW |
Semiconductor Chillers (TES series) (Custom Designs)
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | up to 25kW | up to 25kW | up to 60kW |
Semiconductor Chillers (LTS series) (Custom Designs)
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Chillers for Energy Storage(Custom Designs)
Liquid Cooling Solutions For Battery Energy Storage Systems
Temperature range | -45°C ~ +55°C |
Cooling Capacity | up to 45kW |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |