Features:
- UST series with the function of cooling down from high temperature and the temperature range from 50℃ to 300℃.
- Equipped with heating and cooling system, large heat exchange area, rapid speed of heating-cooling, the small demand for heat conducting medium.
- Can offer heating and cooling continuously.
- The whole system is closed,there is no oil mist at high temperature, novolatilization of heat conducting medium at high temperature.
- With inter temperature sensor PT100 to adjust internal circulation temperature.
- The whole system is a closed liquid circulation system with expansion tank, the expansion tank, and liquid circulation are thermal insulation, do not participate in liquid circulation,regardless of high or low temperature, the medium in the expansion tank is limited to 60℃.
- Allow fill in 15℃ cooling water, to enlarge temperature range of 25℃ to 300℃.
Customer Case


Contact Us For More Information
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 15251628237
Model |
UST-3530 |
UST-5530 |
UST-7530 |
UST-A1030 |
UST-A1530 |
UST-A2530 |
UST-A3830 |
UST-A6030 |
UST-A9530 |
Temp. range |
RT+10°C~+300℃ |
Control Mode |
Feedback PID + Our special dynamic control calculation, PLC controller |
Temp. control |
Process temp. control and jacket temp. control model |
Temp. difference |
Set or control the temperature difference between jacket oil and raw material process |
Program Editor |
10 programs, each program can edit 40 steps. |
Communication Portocol |
MODBUS RTU Protocol,RS485 interface |
Material temp. feedback |
PT100 OR 4~20mA or communication(normal: PT100) |
Temp. feedback |
The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor) |
Medium temp. acccuracy |
±0.5℃ |
±1℃ |
Material temp. accuracy |
±1℃ |
Heating power kW |
3.5 |
5.5 |
7.5 |
10 |
15 |
25 |
38 |
60 |
95 |
Cooling capacity kW at ℃ |
300 ℃ |
3.5 |
5.5 |
7.5 |
10 |
15 |
25 |
38 |
60 |
95 |
200 ℃ |
3.5 |
5.5 |
7.5 |
10 |
15 |
25 |
38 |
60 |
95 |
100 ℃ |
2.8 |
4 |
5 |
7 |
12 |
20 |
30 |
48 |
76 |
65 ℃ |
1 |
1.8 |
2.2 |
3 |
5 |
8.5 |
12 |
19 |
30 |
Circulation pump max
L/min bar |
35 |
35 |
50 |
50 |
110 |
150 |
200 |
250 |
400 |
2 |
2 |
2 |
2 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
Operation Panel |
7-inch touch screen,show temp curveEXCEL data output |
Safety protection |
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
Closed circulation system |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
Connection size |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG1 |
DN32 PN10 |
DN40 PN10 |
DN40 PN10 |
DN50 PN10 |
Connection size |
ZG1/2 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG1 |
DN32 PN10 |
DN40 PN10 |
DN40 PN10 |
DN50 PN10 |
Dimension cm |
40*70*130 |
40*70*130 |
45*70*160 |
45*70*160 |
70*100*175 |
70*100*175 |
80*120*185 |
150*100*185 |
200*145*205 |
Weight kg |
95 |
110 |
120 |
160 |
195 |
265 |
395 |
615 |
950 |
Power 380V 50HZ |
5KW |
7KW |
9KW |
12kw |
17kw |
28kw |
41kw |
65kw |
101kw |

Contact Us For More Information
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 15251628237
Model |
UST-3530 |
UST-5530 |
UST-7530 |
UST-A1030 |
UST-A1530 |
UST-A2530 |
UST-A3830 |
UST-A6030 |
UST-A9530 |
Temp. range |
RT+10°C~+300℃ |
Control Mode |
Feedback PID + Our special dynamic control calculation, PLC controller |
Temp. control |
Process temp. control and jacket temp. control model |
Temp. difference |
Set or control the temperature difference between jacket oil and raw material process |
Program Editor |
10 programs, each program can edit 40 steps. |
Communication Portocol |
MODBUS RTU Protocol,RS485 interface |
Material temp. feedback |
PT100 OR 4~20mA or communication(normal: PT100) |
Temp. feedback |
The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor) |
Medium temp. acccuracy |
±0.5℃ |
±1℃ |
Material temp. accuracy |
±1℃ |
Heating power kW |
3.5 |
5.5 |
7.5 |
10 |
15 |
25 |
38 |
60 |
95 |
Cooling capacity kW at ℃ |
300 ℃ |
3.5 |
5.5 |
7.5 |
10 |
15 |
25 |
38 |
60 |
95 |
200 ℃ |
3.5 |
5.5 |
7.5 |
10 |
15 |
25 |
38 |
60 |
95 |
100 ℃ |
2.8 |
4 |
5 |
7 |
12 |
20 |
30 |
48 |
76 |
65 ℃ |
1 |
1.8 |
2.2 |
3 |
5 |
8.5 |
12 |
19 |
30 |
Circulation pump max
L/min bar |
35 |
35 |
50 |
50 |
110 |
150 |
200 |
250 |
400 |
2 |
2 |
2 |
2 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
Operation Panel |
7-inch touch screen,show temp curveEXCEL data output |
Safety protection |
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
Closed circulation system |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
Connection size |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG1 |
DN32 PN10 |
DN40 PN10 |
DN40 PN10 |
DN50 PN10 |
Connection size |
ZG1/2 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG1 |
DN32 PN10 |
DN40 PN10 |
DN40 PN10 |
DN50 PN10 |
Dimension cm |
40*70*130 |
40*70*130 |
45*70*160 |
45*70*160 |
70*100*175 |
70*100*175 |
80*120*185 |
150*100*185 |
200*145*205 |
Weight kg |
95 |
110 |
120 |
160 |
195 |
265 |
395 |
615 |
950 |
Power 380V 50HZ |
5KW |
7KW |
9KW |
12kw |
17kw |
28kw |
41kw |
65kw |
101kw |
Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com