Search the entire website

UST  RT+10°C ~ +300°C    High Temperature Heaters

UST RT+10°C ~ +300°C High Temperature Heaters

  • Temperature Control Range: RT+10°C ~ +300 °C
  • Temperature Control Accuracy: ±0.5 °C

 

Contact us now to get the latest discount price!

Email: Lilia@lneya.com    WhatsApp: +86 15251628237

WhatsApp        /        WeChat
scan

 

 

 

 

Features:

  • UST series with the function of cooling down from high temperature and the temperature range from 50℃ to 300℃.
  • Equipped with heating and cooling system, large heat exchange area, rapid speed of heating-cooling, the small demand for heat conducting medium.
  • Can offer heating and cooling continuously.
  • The whole system is closed,there is no oil mist at high temperature, novolatilization of heat conducting medium at high temperature.
  • With inter temperature sensor PT100 to adjust internal circulation temperature.
  • The whole system is a closed liquid circulation system with expansion tank, the expansion tank, and liquid circulation are thermal insulation, do not participate in liquid circulation,regardless of high or low temperature, the medium in the expansion tank is limited to 60℃.
  • Allow fill in 15℃ cooling water, to enlarge temperature range of 25℃ to 300℃.

Customer Case

request

Contact Us For More Information

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 15251628237

 

Model UST-3530 UST-5530 UST-7530 UST-A1030 UST-A1530 UST-A2530 UST-A3830 UST-A6030 UST-A9530
Temp. range RT+10°C~+300℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃ ±1℃
Material temp. accuracy ±1℃
Heating power kW 3.5 5.5 7.5 10 15 25 38 60 95
Cooling capacity kW at  ℃ 300 ℃ 3.5 5.5 7.5 10 15 25 38 60 95
200 ℃ 3.5 5.5 7.5 10 15 25 38 60 95
100 ℃ 2.8 4 5 7 12 20 30 48 76
65 ℃ 1 1.8 2.2 3 5 8.5 12 19 30
Circulation pump max
L/min bar
35 35 50 50 110 150 200 250 400
2 2 2 2 2.5 2.5 2.5 2.5 2.5
Operation Panel 7-inch touch screen,show temp curveEXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Connection size ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
Connection size ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
Dimension cm 40*70*130 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205
Weight kg 95 110 120 160 195 265 395 615 950
Power 380V 50HZ 5KW 7KW 9KW 12kw 17kw 28kw 41kw 65kw 101kw

request

Contact Us For More Information

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 15251628237

 

Model UST-3530 UST-5530 UST-7530 UST-A1030 UST-A1530 UST-A2530 UST-A3830 UST-A6030 UST-A9530
Temp. range RT+10°C~+300℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃ ±1℃
Material temp. accuracy ±1℃
Heating power kW 3.5 5.5 7.5 10 15 25 38 60 95
Cooling capacity kW at  ℃ 300 ℃ 3.5 5.5 7.5 10 15 25 38 60 95
200 ℃ 3.5 5.5 7.5 10 15 25 38 60 95
100 ℃ 2.8 4 5 7 12 20 30 48 76
65 ℃ 1 1.8 2.2 3 5 8.5 12 19 30
Circulation pump max
L/min bar
35 35 50 50 110 150 200 250 400
2 2 2 2 2.5 2.5 2.5 2.5 2.5
Operation Panel 7-inch touch screen,show temp curveEXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Connection size ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
Connection size ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
Dimension cm 40*70*130 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205
Weight kg 95 110 120 160 195 265 395 615 950
Power 380V 50HZ 5KW 7KW 9KW 12kw 17kw 28kw 41kw 65kw 101kw

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                  WeChat

Labelheating circulatorsheating systems
Request a Quote
Name
Email Address
Phone
Company
Message