Please Search Dynamic temp. control systems Ultra-Low Temp. Chillers NEV Test Chillers Thermal Test & Process Cooling TCU Unit

SUNDI -60°C ~ +300°C    Heater Cooler Unit

SUNDI -60°C ~ +300°C Heater Cooler Unit

  • Temperature Control Range: -60°C ~ +300 °C
  • Temperature Control Accuracy: ±0.5 °C
  • 7-Inch,10 Inch color FTF Touch Screen Display

Note: Both Air Cooled And Water Cooled Are Available. Explosion Proof Cabinet Can Be Customized.

 

Application: Various Reactors (Micro-channels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Request a Quote          Email Us           More Product Models

Advantages of SUNDI Dynamic Temperature Control System

  • Previously unachievable performance
  • Intelligent temperature control
  • Maximum process stability and reproducibility
  • Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
  • Large temperature range without fluid change
  • Closed system, extend thermal fluid lifetime
  • Incredibly compact
  • 7-inch, 10-inch color TFT touch screen display
  • Comprehensive warning and safety functions
  • Use magnetic drive pump, solve the circulation pump leakage

Circulation Pump

High temperature resistant low temperature magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.

Configuration Software (Optional)

  • All SUNDI-series dynamic temperature control systems can be connected to a computer. You can install and record the display screen on the computer through the configuration software.
  • Communication distance is less than 200m
  • Easily set temperature
  • real-time control screen
  • Curve record temperature control process
  • Program selection
  • Alarm record

Customer Cases

Structure and Principle of Dynamic Temperature Control System: 

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃(because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ and - 30℃ ~ 300℃ can be realized without pressurization.

 

Note: please leave your detailed requirements, we will select or customize products for you.

Message                  Email                      WhatsApp

Model SUNDI-655WV SUNDI-675WV SUNDI-6A10WV SUNDI-6A15WV SUNDI-6A25WV
Temp. range -60℃~+300℃ (system add pressure 3BAR)
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp control and jacket temp control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp of three points: the inlet and outlet of equipment,  reactor material temp(external temp sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 5.5 7.5 10 15 25
Cooling capacity kW at 300℃ 5.5 7.5 10 15 25
100℃ 5.5 7.5 10 15 25
20℃ 5.5 7.5 10 15 25
-20℃ 4.8 6 8.2 12 25
-40℃ 2.3 3.1 4.8 7.8 18
-55℃ 0.75 0.9 1.5 2.8 6
Circulation pump max
L/min bar
35 50 60 110 150
2 2 2.5 2.5 2.5
Pump LNEYA magnetic drive pump
Compressor Tecumseh closed compressor Dorin semi-closed compressor
Expansion valve Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23 mixture,optional: R125/R23 mixture
Connection size G3/4 G1 G1 G1 DN32 PN10
Water-cooled type W(cooling water@20℃) 1800L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
3000L/H
1.5bar~4bar
4000L/H
1.5bar~4bar
8.5m³/H
1.5bar~4bar
Dimension cm 55*100*175 55*100*175 70*100*175 80*120*185 100*150*185
Weight kg 265 305 340 380 980
Power 380V 50HZ 10kW 14kW 18kW 26kW 40kW

Note: please leave your detailed requirements, we will select or customize products for you.

Message                  Email                      WhatsApp

Model SUNDI-655WV SUNDI-675WV SUNDI-6A10WV SUNDI-6A15WV SUNDI-6A25WV
Temp. range -60℃~+300℃ (system add pressure 3BAR)
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp control and jacket temp control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp of three points: the inlet and outlet of equipment,  reactor material temp(external temp sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 5.5 7.5 10 15 25
Cooling capacity kW at 300℃ 5.5 7.5 10 15 25
100℃ 5.5 7.5 10 15 25
20℃ 5.5 7.5 10 15 25
-20℃ 4.8 6 8.2 12 25
-40℃ 2.3 3.1 4.8 7.8 18
-55℃ 0.75 0.9 1.5 2.8 6
Circulation pump max
L/min bar
35 50 60 110 150
2 2 2.5 2.5 2.5
Pump LNEYA magnetic drive pump
Compressor Tecumseh closed compressor Dorin semi-closed compressor
Expansion valve Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23 mixture,optional: R125/R23 mixture
Connection size G3/4 G1 G1 G1 DN32 PN10
Water-cooled type W(cooling water@20℃) 1800L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
3000L/H
1.5bar~4bar
4000L/H
1.5bar~4bar
8.5m³/H
1.5bar~4bar
Dimension cm 55*100*175 55*100*175 70*100*175 80*120*185 100*150*185
Weight kg 265 305 340 380 980
Power 380V 50HZ 10kW 14kW 18kW 26kW 40kW
Previous: Next: