Search the entire website

SUNDI -40°C ~ +200°C    Heating and Cooling Systems

SUNDI -40°C ~ +200°C Heating and Cooling Systems

  • Temperature Control Range: -40°C ~ +200°C One Machine for Two Reactors
  • Temperature Control Accuracy: ±0.5 °C
  • 7-Inch,10 Inch color FTF Touch Screen Display

Note: Both Air Cooled And Water Cooled Are Available. Explosion Proof Cabinet Can Be Customized.

 

Application: Various Reactors (Micro-channels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Request a Quote          Email Us           More Product Models

Advantages of SUNDI Dynamic Temperature Control System

  • Previously unachievable performance
  • Intelligent temperature control
  • Maximum process stability and reproducibility
  • Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
  • Large temperature range without fluid change
  • Closed system, extend thermal fluid lifetime
  • Incredibly compact
  • 7-inch, 10-inch color TFT touch screen display
  • Comprehensive warning and safety functions
  • Use magnetic drive pump, solve the circulation pump leakage

Circulation Pump

High temperature resistant low temperature magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.

Configuration Software (Optional)

  • All SUNDI-series dynamic temperature control systems can be connected to a computer. You can install and record the display screen on the computer through the configuration software.
  • Communication distance is less than 200m
  • Easily set temperature
  • real-time control screen
  • Curve record temperature control process
  • Program selection
  • Alarm record

Customer Cases

Structure and Principle of Dynamic Temperature Control System: 

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃(because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ and - 30℃ ~ 300℃ can be realized without pressurization.

 

Note: please leave your detailed requirements, we will select or customize products for you.

Message                  Email                      WhatsApp

Model SUNDI-425W-2T N
SUNDI-425-2T N
SUNDI-435W-2T N
SUNDI-435-2T N
SUNDI-455W-2T N
SUNDI-455-2T N
SUNDI-475W-2T N
SUNDI-475-2T N
SUNDI-4A10W-2T N
SUNDI-4A10-2T N
Temp. range -40℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model   TWO  GROUPS
Temp. difference Set or control the temperature difference between jacket oil and raw material process  TWO  GROUPS
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback the temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)*2
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 2.5*2 3.5*2 5.5*2 7.5*2 10*2
Cooling capacity kW at  ℃ 200℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
100℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
20℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
0℃ 1.5*2 2.5*2 3.5*2 5*2 7.5*2
-20℃ 1*2 1.6*2 2.1*2 3*2 4*2
-35℃ 0.45*2 0.75*2 1*2 1.4*2 1.8*2
Circulation pump max
L/min bar
20*2 35*2 35*2 50*2 50*2
1.5 2 2 2 2
Compressor Tecumseh/Highly  Emerson copeland vortex flexible
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curveEXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G3/4 G3/4 G3/4 G3/4 G1
Water-cooled type W(cooling water@20℃) 1200L/H
1.5bar~4bar
1400L/H
1.5bar~4bar
1700L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
2500L/H
1.5bar~4bar
Dimension(water type)cm 55*100*175 70*100*175 70*100*175 80*120*185 100*150*185
Dimension(air type)cm 55*100*175 55*100*175 70*100*175 70*100*175 80*120*185
weight kg 240 285 345 385 480
power 380V 50HZ 220V  8kW 12kW 17.5kW 24kW 33kW

Note: please leave your detailed requirements, we will select or customize products for you.

Message                  Email                      WhatsApp

Model SUNDI-425W-2T N
SUNDI-425-2T N
SUNDI-435W-2T N
SUNDI-435-2T N
SUNDI-455W-2T N
SUNDI-455-2T N
SUNDI-475W-2T N
SUNDI-475-2T N
SUNDI-4A10W-2T N
SUNDI-4A10-2T N
Temp. range -40℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model   TWO  GROUPS
Temp. difference Set or control the temperature difference between jacket oil and raw material process  TWO  GROUPS
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback the temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)*2
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 2.5*2 3.5*2 5.5*2 7.5*2 10*2
Cooling capacity kW at  ℃ 200℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
100℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
20℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
0℃ 1.5*2 2.5*2 3.5*2 5*2 7.5*2
-20℃ 1*2 1.6*2 2.1*2 3*2 4*2
-35℃ 0.45*2 0.75*2 1*2 1.4*2 1.8*2
Circulation pump max
L/min bar
20*2 35*2 35*2 50*2 50*2
1.5 2 2 2 2
Compressor Tecumseh/Highly  Emerson copeland vortex flexible
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curveEXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G3/4 G3/4 G3/4 G3/4 G1
Water-cooled type W(cooling water@20℃) 1200L/H
1.5bar~4bar
1400L/H
1.5bar~4bar
1700L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
2500L/H
1.5bar~4bar
Dimension(water type)cm 55*100*175 70*100*175 70*100*175 80*120*185 100*150*185
Dimension(air type)cm 55*100*175 55*100*175 70*100*175 70*100*175 80*120*185
weight kg 240 285 345 385 480
power 380V 50HZ 220V  8kW 12kW 17.5kW 24kW 33kW

 

CUSTOM OPTIONS

  • CUSTOM SIZES

Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements.

No matter how many tons of chiller you need, we can create the best solution.

  • CUSTOM TEMPERATURE RANGES

We can create a custom solution for temperatures from -150℃ to +350℃.

Custom temperature ranges for specific industries.

  • CUSTOM COOLING/HEATING CAPACITY

We offer a very wide range of cooling/heating capacities for various industries.

  • CUSTOM TYPES

We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers.

Regardless of the type of refrigeration compressor, we can design it according to your requirements.

  • CUSTOM ACCESSORIES

We use a variety of internationally renowned accessories, all of which can be customized for your needs, such as compressors, evaporators, heat exchangers, circulation pumps, controllers, expansion valves and shell materials, etc.

  • CUSTOM VOLTAGE

Customize chiller voltage and phase according to your needs.

Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.

  • OTHER CUSTOMIZED SOLUTIONS

 

Tell Us More About Your Needs       

 

OUR ADVANTAGES

We offer:

Experience you can count on—

We’ve been designing and building custom products for more than 20 years. From medical chillers to energy storage chillers and everything in between, we’ve built products for virtually every industry and every application.

Same day quotes—

Get a quote for your project today! We often provide custom quotes in as little as 30 minutes.

24/7 customer service—

We are always here for you. Whether you have a question or need a quote, there’s always somebody here to communicate with you 24/7.

Durable, reliable equipment—

Our products are built with premium-grade materials, and we offer competitive warranties on all custom products.

 

Request A Quote                  Email Us                      WhatsApp

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Labelcooling heating systemsheater & chillerHeater chiller combo Next:
Request a Quote
Name
Email Address
Phone
Company
Message