Pesquisar Pesquisar tudo

Installation Precautions for Chiller Room

ClassificaçãoNotícias do sector 241

Installation Precautions for Chiller Room

 

What matters should be paid attention to when building a chiller room? The purpose of the machine room is to allow the equipment to have an independent and stable operating environment, avoid wind and sun, and damage to the equipment caused by various sundries or dust, ensure the long-term stable operation of the chiller, and prolong the service life. From this point of view, the construction of the machine room is very necessary. So what issues should we consider when building a chiller room?

The first point: the site of the chiller room

The foundation is where the foundation lies. Therefore, the first thing we need to determine is the installation location, and we must choose a stable and open place. And it is an independent building of a machine room to avoid sharing space with other equipment, especially for high-power screw chillers, the installation site should ensure that it will not be exposed to sunlight or rain, and to avoid pollution and corrosion. After the equipment is installed, enough space can be left to maintain air circulation, which is convenient for later maintenance.

The second point: the power supply and water source of the chiller

The main function of the chiller is refrigeration, providing low-temperature process chilled water to the cooled equipment. Power and water sources must be considered. Before installation, be sure to run the electricity strictly according to the power supply on the nameplate, and ensure that the voltage and current are stable. To meet the electricity standards of the chiller refrigeration system, especially the power load and grounding parts, must be constructed in accordance with relevant regulations.

It is necessary to use pipes to connect the water source to the chiller. Please configure the piping according to the size of the chiller’s throat. Do not reduce or expand the size of the water pipe, so as to avoid high pressure overload or insufficient water circulation, which will cause the equipment to fail to operate normally. Whether it is wiring or piping, it must be properly designed and fixed. Especially the pipeline, the unreasonable arrangement will directly affect the cooling water flow. In addition, the chilled water pipeline of the chiller must remember to pack insulation!

The third point: the stability and vibration reduction of the chiller

We require that the installation of the chiller must ensure that the ground is flat and stable. The equipment will have a certain amplitude during operation, and the vibration will not only generate noise, but also cause displacement of the chiller. Therefore, when installing the chiller, the factory can adopt vibration damping accessories to reduce noise and vibration, and the equipment must be tightened.

Nós somos um fabricante profissional de equipamento de controlo de temperatura, apoiando serviços personalizados, por favor consulte-nos para mais pormenores!

 


refrigerador de água de baixa temperatura

Refrigeradores de água

Gama de controlo de temperatura: -150°C a +50°C

 

 


sistema de arrefecimento e aquecimento

Sistemas dinâmicos de controlo da temperatura

Gama de controlo de temperatura: -120°C a +350°C

 

 

 


sistema de arrefecimento da bateria

Refrigeradores de teste para automóveis

Gama de controlo de temperatura: -40°C a +100°C

 

 

 


refrigerador de teste de semicondutores

Refrigeradores de teste de semicondutores

Gama de controlo de temperatura: -85°C a +250°C

 

 

 


congelador industrial

Frigoríficos industriais

Gama de controlo de temperatura: -150°C a -10°C

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água