Product parameter

  • Power:9.5kW
  • Heating power:5.5kW
  • Flow:35L/min
  • Pressure:2bar
  • Temperature control accuracy:±0.5℃

All products support customized services

 

Request a Quote       Email Us        More Product Models

Typical Application Of Dynamic Temperature Control System:

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor. Micro-channel reactor thermostatic control, small temperature control system, steam – feeding system temperature control, material low temperature aging test. The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Structure and principle of Dynamic Temperature Control System: 

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃(because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Advantages of Equipment Functions and Accessories

When the temperature is high, there is no evaporation of heat conducting medium, and the continuous temperature control of -90~195℃,-70~220℃,-55~250℃ and -25~300℃ can be realized without pressure. Adopt the design of fully closed pipeline, reduce the demand of heat-transfer fluid, improve the heat utilization rate of the system, and achieve rapid temperature rise and fall. The heat conducting medium in the expansion vessel does not participate in the circulation, which can reduce the risk of moisture absorption and volatilization during the operation of the heat conducting medium.

Product parameters(All products can be customized

Model SUNDI-555WV
Temp. range -45℃~+300℃  (the system add pressure 3bar)
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 42 steps.
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power 5.5
Cooling capacity kW at 250℃ 5.5
100℃ 5.5
20℃ 5.5
0℃ 5
-20℃ 2.9
-40℃ 0.9
Circulation pump max
L/min bar
50
2
Pump LNEYA magnetic drive pump
Compressor DANFOSS/ Emerson copeland vortex flexible
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G3/4
Water-cooled type W(cooling water@20℃) 1500L/H
1.5bar~4bar
Dimension mm 450*850*1300
Isolate size mm 450*1100*1300
Positive pressure mm 1100*950*1950
Weight kg 245
Power 380V 50HZ 9.5kW max

Detailed parameters

Weight 245 kg
Dimensions 45 × 85 × 130 cm
Max Working Temp.

300℃

Min Working Temp.

-45℃

Power

5~10kW

Temp. Accuracies

±0.5℃

LNEYA attends various exhibitions at home and abroad every year. At the exhibition, we show the latest research equipment of LNEYA. Every year, long-term cooperative customers will come to exhibitions and communicate with us. We are also actively developing new customers to provide them with high quality machines and services.

After sale service

Quality assurance

Guarantee that the goods are sold to be conform to the provisions of the contract and qualified new products by factory inspection, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract.

Installation and debugging

After the arrival of the goods, my company or my company agent is responsible for installation and debugging of equipment need on-site installation and debugging.

Inspection and acceptance

After installation and debugging, acceptance by the customer to confirm the goods to be conform to the provisions of the contract and qualified new products, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract, and after the confirmation of a full set of technical documents, sign the installation acceptance report and confirm acceptance.

Training

At the same time of installation and debugging of equipment, my company’s after-sales service engineer is responsible for technical training for user until user can be skilled of operation. In the process of using equipment by customer, customer can consult relevant technical issues to after-sales service personal of our company at any time, according to the situation, my company will arrange training on site or remote.

After sale service commitment

A full free one year warranty since the date of acceptance, during the warranty period, all repairs and spare parts are free of charge(instrukent malfunction caused bu human factors will be charged of cost price of spare parts); After the warranty period, we will be responsible for maintenance of equipment for lifetime, according to the actual maintenance fees, appropriate fee will be charged.

(PS:There will have extra charge if the customer need on-site service. And customers need to describe the issue first and then send some failed pics or videos in advance, then Lneya judge if it is possible to go for after-Sales on site. )

Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller