LT-65A1N Low Temperature Recirculating Water Chiller
Product parameter
- Power:7kW
- Cooling power(AT-60℃):2kW
- Flow:50L/min
- Pressure:1bar
All products support customized services
Ship To
TEL: + 86-187515465184
Please Search Dynamic temp. control systems Ultra-Low Temp. Chillers NEV Test Chillers Thermal Test & Process Cooling TCU Unit
All products support customized services
Ship To
Detailed Description
The product adopts the international brand compressor Carlyle, which is small in size and high in efficiency. The single compressor can realize the temperature control of -152 °C, and the ultra-low temperature refrigeration technology is at the international advanced level.
1. To save water resources, it is possible to use the glycol-water mixture to carry out circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, and prolong the use time of circulating water;
2. Original imported compressor, overlapping super-cooled refrigeration technology;
3. Double condensation high efficiency system;
4. Computer cascade temperature controller, temperature digital display, adjustment unit 0.1 degree, PT100 temperature sensor, -125°C~ -20°C wide temperature range;
5. Ambient temperature monitoring function to prevent the system operating environment temperature from being too high;
6. It adopts full-closed design, no water absorption during low-temperature operation, ensuring the purity of cold and heat-conductive medium, preventing ice crystals and improving the life of thermal fluid.
Model | LT-65A1N | ||||||
Medium Temperature Range | -60℃~-20℃ | ||||||
Temp. Control and Dispaly | ASET multifunctional controller, control outlet temperature of water tank | ||||||
Temp. Control Optional | Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||||
Cooling Capacity | -20℃ | 4.8KW | |||||
-40℃ | 4KW | ||||||
-60℃ | 2KW | ||||||
Circulation Pump Flow Rate, Pressure (max) | 75L/min 1BAR |
||||||
Capacity of Liquid Storage | 40L | ||||||
Compressor | Tecumseh, Dorin | ||||||
Evaporator | Plate Heat Exchanger | ||||||
Operation Panel | 7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record, data export excel-format | ||||||
Safety Protection | Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function. | ||||||
Refrigerant | R-404A/R23 mixed refrigerant | ||||||
Connection Size | G1 | ||||||
Product size(air-cooled)(cm) | 70*100*175 | ||||||
Weight (air-cooled) | 340kg | ||||||
Power 50HZ max |
AC380V 7kW |
||||||
Shell Material | Cold rolled steel painting | ||||||
Optional | Circulation pump 35L/min 2.5bar、50L/min 2.5bar、110L/min 2.5bar optional | ||||||
Optional | Pressure ≤6 bar circulating pump | ||||||
Optional | MODBUS RTU Protocol, RS 485 Interface | ||||||
Optional | SUS304 Material | ||||||
Optional Power | 220V 60HZ three-phases,460V 60HZ three-phases | ||||||
Remark | Can make the bigger capacity of liquid storage as required. |
LNEYA attends various exhibitions at home and abroad every year. At the exhibition, we show the latest research equipment of LNEYA. Every year, long-term cooperative customers will come to exhibitions and communicate with us. We are also actively developing new customers to provide them with high quality machines and services.
Guarantee that the goods are sold to be conform to the provisions of the contract and qualified new products by factory inspection, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract.
After the arrival of the goods, my company or my company agent is responsible for installation and debugging of equipment need on-site installation and debugging.
After installation and debugging, acceptance by the customer to confirm the goods to be conform to the provisions of the contract and qualified new products, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract, and after the confirmation of a full set of technical documents, sign the installation acceptance report and confirm acceptance.
At the same time of installation and debugging of equipment, my company’s after-sales service engineer is responsible for technical training for user until user can be skilled of operation. In the process of using equipment by customer, customer can consult relevant technical issues to after-sales service personal of our company at any time, according to the situation, my company will arrange training on site or remote.
A full free one year warranty since the date of acceptance, during the warranty period, all repairs and spare parts are free of charge(instrukent malfunction caused bu human factors will be charged of cost price of spare parts); After the warranty period, we will be responsible for maintenance of equipment for lifetime, according to the actual maintenance fees, appropriate fee will be charged.