Please Search Dynamic temp. control systems Ultra-Low Temp. Chillers NEV Test Chillers Thermal Test & Process Cooling TCU Unit

LT  -45°C ~ +30°C    Low Temperature Circulators

LT -45°C ~ +30°C Low Temperature Circulators

  • Temperature Control Range: -45°C ~ +30°C
  • Siemens PLC Controller, Danfoss Electronic Expansion Valve
  • Brand Compressor, Cascade Refrigeration Cooling Technologies

Note: Both Air Cooled And Water Cooled Are Available. Explosion Proof Cabinet Can Be Customized.

 

Application: Various Reactors, Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Biological and Other Industries.

 

Request a Quote          Email Us           More Product Models

LNEYA specializes in the production of cryogenic circulators, a very wide refrigeration temperature range, and a controllable temperature of -120 ~ 30℃. It adopts secondary sub-cooling, fast cooling speed, safe and reliable, and is used for rapid liquid cooling. It is widely used in high-tech industries such as petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical and so on.

Advantages of Low Temperature Recirculating Chiller

  • Saving resources. Closed cycle pipeline design highly prevent circulating water pollution and extend the lifetime of circulation liquid.
  • Brand compressor, cascade refrigeration cooling technologies.Human design, more convenient and flexible.
  • Computer-cascade temperature controller,temperature figures display, adjustable unit is 0.1°C,temperature. range is -120°℃~30°C, PT100 temperature sensor.
  • A variety of fault alarm (over-temperature alarm, sensor alarm, high pressure alarm, compressor over heat alarm,liquid level alarm).
  • Power on delay protection, three-level cascade system protectors.All parts are safety grounding.
  • Adopt full closed circulation design, no water vapor at low temperature and ensure the purity of cooling medium, in case of ice crystals, provide a long time life of heat transfer liquid.
  • High-performance circulating pump, can guarantee 24 hours continuously running a day.Use plate cool-heat-exchanger, heat transfer efficiency is provided.

Customer Case

 

Note: please leave your detailed requirements, we will select or customize products for you.

Message                  Email                      WhatsApp

Model LT-5018N LT-5040N LT-5062N LT-5090N LT-50A1N LT-50A2N
Medium Temperature Range  -37℃~30℃ -45℃~30℃
Temp. Control and Dispaly  ASET multifunctional controller, control outlet temperature of water tank
Temp. Control Optional Temperature feedback PT100 (inlet temperature, outlet temperature)
Cooling Capacity -10℃ 1.5KW 3.2KW 4.5KW 6.2KW 8.3KW 12KW
-20℃ 1.2KW 2.7KW 3.8KW 5.5KW 7KW 10KW
-40℃ 0.4KW 0.75KW 1.15KW 1.5KW 2.1KW 3KW
Circulation Pump Flow Rate, Pressure  (max) 20L/min
0.7BAR
20L/min
0.7BAR
35L/min
1BAR
35L/min
1BAR
75L/min
1BAR
75L/min
1BAR
Capacity of Liquid Storage 15L 20L 25L 30L 50L 80L
Compressor Tecumseh, Emerson Copeland, Danfoss
Evaporator Plate Heat Exchanger
Operation Panel         7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A/R507C
Connection Size G1/2 G3/4 G3/4 G3/4 G1 G1
Product size(air-cooled)(cm) 50*85*130 55*68*145 55*100*175 70*100*175 70*100*175 80*120*185
Weight (air-cooled) 145KG 185kg 230kg 275kg 340kg 380kg
Power 50HZ
max
AC220V
1.6kW
AC380V
2.5kW
AC380V
3.5kW
AC380V
4.8kW
AC380V
6kW
AC380V
8kW
Shell Material Cold rolled steel painting
Optional Pressure ≤6 bar circulating pump
Optional  MODBUS RTU Protocol, RS 485 Interface
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,460V 60HZ three-phases
Remark Can make the bigger capacity of liquid storage as required.

Note: please leave your detailed requirements, we will select or customize products for you.

Message                  Email                      WhatsApp

Model LT-5018N LT-5040N LT-5062N LT-5090N LT-50A1N LT-50A2N
Medium Temperature Range  -37℃~30℃ -45℃~30℃
Temp. Control and Dispaly  ASET multifunctional controller, control outlet temperature of water tank
Temp. Control Optional Temperature feedback PT100 (inlet temperature, outlet temperature)
Cooling Capacity -10℃ 1.5KW 3.2KW 4.5KW 6.2KW 8.3KW 12KW
-20℃ 1.2KW 2.7KW 3.8KW 5.5KW 7KW 10KW
-40℃ 0.4KW 0.75KW 1.15KW 1.5KW 2.1KW 3KW
Circulation Pump Flow Rate, Pressure  (max) 20L/min
0.7BAR
20L/min
0.7BAR
35L/min
1BAR
35L/min
1BAR
75L/min
1BAR
75L/min
1BAR
Capacity of Liquid Storage 15L 20L 25L 30L 50L 80L
Compressor Tecumseh, Emerson Copeland, Danfoss
Evaporator Plate Heat Exchanger
Operation Panel         7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A/R507C
Connection Size G1/2 G3/4 G3/4 G3/4 G1 G1
Product size(air-cooled)(cm) 50*85*130 55*68*145 55*100*175 70*100*175 70*100*175 80*120*185
Weight (air-cooled) 145KG 185kg 230kg 275kg 340kg 380kg
Power 50HZ
max
AC220V
1.6kW
AC380V
2.5kW
AC380V
3.5kW
AC380V
4.8kW
AC380V
6kW
AC380V
8kW
Shell Material Cold rolled steel painting
Optional Pressure ≤6 bar circulating pump
Optional  MODBUS RTU Protocol, RS 485 Interface
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,460V 60HZ three-phases
Remark Can make the bigger capacity of liquid storage as required.
Previous: Next:
展开更多
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller