검색 모두 검색

Cleaning Methods of Laboratory Refrigeration and Heating System

분류업계 뉴스 328

 

Cleaning Methods of Laboratory Refrigeration and Heating System

 

The laboratory refrigeration and heating system is widely used in the pharmaceutical and chemical industry. The heat transfer oil is used as the heat transfer medium, and the refrigerant is used as the cooling liquid to realize the temperature control process of refrigeration and heating. Long-term operation of the equipment can cause scaling on the surface of the condenser, which can interfere with the normal operation of the laboratory refrigeration and heating system. In order to maintain the working efficiency of the equipment, the user needs to clean the equipment regularly.

1. The laboratory refrigeration and heating system is an integrated device. The refrigeration system and the heating system are installed in the chassis. This type of equipment is generally installed indoors. The placement location is preferably a well-ventilated, dust-free and cool stable floor or laboratory table. Avoid Avoid places where there is a lot of droplets and steam, and avoid places where inflow, stagnation, and leakage of flammable gas may occur, avoid devices that generate high frequency (high-frequency welding machines, etc.), and avoid places where acid solutions are frequently used.

2. If you want to clean the equipment, you must disassemble it first, because the parts to be cleaned are inside the collector and are not easy to see. The various components of the refrigeration unit cross each other, and the piping is complicated and difficult to disassemble.

3. After the connection between the cleaning device and the condenser is disassembled in the previous step, find the direction of the water inlet of the condenser and connect it to the water inlet or outlet of the water pump, then use the tool to heat the pipe.

4. Make sure that each step is done and the pipes are connected, first add clean water for cleaning, then discharge the sewage and repeat it for 3 times. After the cleaning is completed, it is important to add medicine and clean. Of course, the pH value should be ensured at 4-5. After 2-3 hours, the potion was drained, and the bio-residual flush was performed to maintain the pH.

5. After the equipment is cleaned, install it back in the original way, which is also an important step in cleaning the laboratory refrigeration and heating system.

We are a professional manufacturer of chillers and temperature control equipment, supporting customized services, please 문의하기 자세한 내용을 확인하세요!

 


냉각 및 난방 시스템

온도 제어 범위: -120°C ~ +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

온도 범위 -40 ~ +200°C 시리즈 -10 ~ +200°C 시리즈 -25 ~ +200°C 시리즈 -25 ~ +300°C 시리즈 -45 ~ +250°C 시리즈 -45 ~ +300°C 시리즈 -60 ~ +250°C 시리즈 -60 ~ +300°C 시리즈 -70 ~ +250°C 시리즈 -80 ~ +250°C 시리즈-90 ~ +250°C 시리즈 -100 ~ +100°C 시리즈 -25 ~ +200°C, 원자로 두 대용 장비 한 대 -40 ~ +200°C, 원자로 두 대용 장비 한 대
냉각 용량최대 3kW최대 15kW최대 200kW최대 200kW최대 200kW최대 25kW최대 60kW최대 25kW최대 15kW최대 80kW최대 80kW최대 80kW최대 10*2kW최대 10*2kW

 


냉각 및 난방 서큘레이터

온도 제어 범위: -45°C ~ +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

온도 범위 -25°C ~ +200°C 시리즈 -45°C ~ +250°C 시리즈
냉각 용량최대 15kW최대 15kW

 

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗